Ultrasound assessment of abdominal adipose panniculus in patients treated with a single session of cryolipolysis in a clinical setting

OBJECTIVE: To assess the effectiveness and safety of cryolipolysis treatment (four‐to‐six cycles in one session) for reducing abdominal fat. METHODS: Retrospective study conducted on consecutive healthy women who underwent one session of cryolipolysis for abdominal fat reduction. Ultrasound images (...

Descripción completa

Detalles Bibliográficos
Autor principal: Ponga‐Manso, Montserrat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9299458/
https://www.ncbi.nlm.nih.gov/pubmed/34813151
http://dx.doi.org/10.1111/jocd.14597
_version_ 1784750979093102592
author Ponga‐Manso, Montserrat
author_facet Ponga‐Manso, Montserrat
author_sort Ponga‐Manso, Montserrat
collection PubMed
description OBJECTIVE: To assess the effectiveness and safety of cryolipolysis treatment (four‐to‐six cycles in one session) for reducing abdominal fat. METHODS: Retrospective study conducted on consecutive healthy women who underwent one session of cryolipolysis for abdominal fat reduction. Ultrasound images (USI) were acquired at baseline and at month 6 after treatment. A patient‐tailored approach based on adipose tissue depth and architecture was selected. RESULTS: Thirty women were included. The mean age was 51.4 ± 3.4 years, and 27 (90%) were menopausal. At month 6, the mean abdominal fat layer thickness reduction was 46.6% (41.2%–51.9%). The mean contour was significantly reduced from 84.3, 99.2, 90.6, and 97.1 cm to 81.0, 93.6, 85.8, and 92.2 cm in the infracostal, supraumbilical, umbilical, and ischiopubic regions, respectively; p < 0.0001 each. There were no significant changes in weight, body mass index, fat mass, or lean mass throughout the study. After adjusting for smoking, exercise, hypothyroidism, and type of fat, there was a significant reduction in abdominal fat layer thickness (−4.5 ± 0.9 mm, p < 0.0001) and contour measurements in infracostal (−3.3 ± 2.4 mm, p = 0.0317); supraumbilical (−4.8 ± 2.1 mm, p = 0.0254); umbilical (−5.6 ± 2.3, p = 0.0161); and ischiopubic (−4.9 ± 1.8 mm, p = 0.0080). The qualitative analysis of the USI suggested the appearance of numerous bands of ordered and structured collagen fibers. CONCLUSIONS: Four‐to‐six cycles of cryolipolysis, administered in one session, seemed to be a safe and effective procedure for reducing localized fat in the abdominal region in this sample. Additionally, ultrasound images suggested that cryolipolysis was associated with a skin quality improvement and neocollagenesis.
format Online
Article
Text
id pubmed-9299458
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-92994582022-07-21 Ultrasound assessment of abdominal adipose panniculus in patients treated with a single session of cryolipolysis in a clinical setting Ponga‐Manso, Montserrat J Cosmet Dermatol Energy Based Devices OBJECTIVE: To assess the effectiveness and safety of cryolipolysis treatment (four‐to‐six cycles in one session) for reducing abdominal fat. METHODS: Retrospective study conducted on consecutive healthy women who underwent one session of cryolipolysis for abdominal fat reduction. Ultrasound images (USI) were acquired at baseline and at month 6 after treatment. A patient‐tailored approach based on adipose tissue depth and architecture was selected. RESULTS: Thirty women were included. The mean age was 51.4 ± 3.4 years, and 27 (90%) were menopausal. At month 6, the mean abdominal fat layer thickness reduction was 46.6% (41.2%–51.9%). The mean contour was significantly reduced from 84.3, 99.2, 90.6, and 97.1 cm to 81.0, 93.6, 85.8, and 92.2 cm in the infracostal, supraumbilical, umbilical, and ischiopubic regions, respectively; p < 0.0001 each. There were no significant changes in weight, body mass index, fat mass, or lean mass throughout the study. After adjusting for smoking, exercise, hypothyroidism, and type of fat, there was a significant reduction in abdominal fat layer thickness (−4.5 ± 0.9 mm, p < 0.0001) and contour measurements in infracostal (−3.3 ± 2.4 mm, p = 0.0317); supraumbilical (−4.8 ± 2.1 mm, p = 0.0254); umbilical (−5.6 ± 2.3, p = 0.0161); and ischiopubic (−4.9 ± 1.8 mm, p = 0.0080). The qualitative analysis of the USI suggested the appearance of numerous bands of ordered and structured collagen fibers. CONCLUSIONS: Four‐to‐six cycles of cryolipolysis, administered in one session, seemed to be a safe and effective procedure for reducing localized fat in the abdominal region in this sample. Additionally, ultrasound images suggested that cryolipolysis was associated with a skin quality improvement and neocollagenesis. John Wiley and Sons Inc. 2021-11-23 2022-01 /pmc/articles/PMC9299458/ /pubmed/34813151 http://dx.doi.org/10.1111/jocd.14597 Text en © 2021 The Authors. Journal of Cosmetic Dermatology published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Energy Based Devices
Ponga‐Manso, Montserrat
Ultrasound assessment of abdominal adipose panniculus in patients treated with a single session of cryolipolysis in a clinical setting
title Ultrasound assessment of abdominal adipose panniculus in patients treated with a single session of cryolipolysis in a clinical setting
title_full Ultrasound assessment of abdominal adipose panniculus in patients treated with a single session of cryolipolysis in a clinical setting
title_fullStr Ultrasound assessment of abdominal adipose panniculus in patients treated with a single session of cryolipolysis in a clinical setting
title_full_unstemmed Ultrasound assessment of abdominal adipose panniculus in patients treated with a single session of cryolipolysis in a clinical setting
title_short Ultrasound assessment of abdominal adipose panniculus in patients treated with a single session of cryolipolysis in a clinical setting
title_sort ultrasound assessment of abdominal adipose panniculus in patients treated with a single session of cryolipolysis in a clinical setting
topic Energy Based Devices
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9299458/
https://www.ncbi.nlm.nih.gov/pubmed/34813151
http://dx.doi.org/10.1111/jocd.14597
work_keys_str_mv AT pongamansomontserrat ultrasoundassessmentofabdominaladiposepanniculusinpatientstreatedwithasinglesessionofcryolipolysisinaclinicalsetting