Cargando…
Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation
OBJECTIVES: Right ventricular (RV) failure post left ventricular assist device (LVAD) implantation is associated with increased morbidity and mortality. A novel RV multi‐plane imaging method using two‐dimensional echocardiography and electronic plane rotation (MPE) was used to quantify RV function p...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9300057/ https://www.ncbi.nlm.nih.gov/pubmed/34877695 http://dx.doi.org/10.1111/echo.15191 |
_version_ | 1784751121640718336 |
---|---|
author | Bowen, Daniel J. Yalcin, Yunus C. Strachinaru, Mihai McGhie, Jackie S. van den Bosch, Annemien E. Soliman, Osama I. Caliskan, Kadir |
author_facet | Bowen, Daniel J. Yalcin, Yunus C. Strachinaru, Mihai McGhie, Jackie S. van den Bosch, Annemien E. Soliman, Osama I. Caliskan, Kadir |
author_sort | Bowen, Daniel J. |
collection | PubMed |
description | OBJECTIVES: Right ventricular (RV) failure post left ventricular assist device (LVAD) implantation is associated with increased morbidity and mortality. A novel RV multi‐plane imaging method using two‐dimensional echocardiography and electronic plane rotation (MPE) was used to quantify RV function prior to LVAD implantation and to identify potential added value in this patient population. METHODS: In twenty‐five end‐stage heart failure patients (age 58.9 ± 6.8 years, 76% male), systolic function of four different RV walls (lateral, anterior, inferior and inferior coronal) were evaluated from one focussed apical view using MPE. RESULTS: Feasibility of tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular peak systolic velocity (RV‐S') measurements were high (84–100%), with lower TAPSE values measured in the inferior (14.2 ± 4.6 mm) and inferior coronal (12.3 ± 5.0 mm) walls compared to the lateral (16.3 ± 4.5 mm) and anterior walls (16.0 ± 4.5 mm). RV wall longitudinal strain (RV‐LS) measurement was most feasible in the lateral wall (80%; mean: –12.1 ± 4.2%). TAPSE and RV‐LS values were significantly reduced in patients compared to matched healthy individuals (p = <0.001). Seven (28%) patients who developed moderate to severe RV failure (RVF) early post‐implant (≤30 days) had lower pre‐implant values across all multi‐plane parameters compared to those without significant post‐implant RVF, notably four‐wall averaged TAPSE (11.1 ± 3.4 mm vs 15.9 ± 4.0 mm; p = 0.02). CONCLUSION: 2D MPE was highly feasible for RV wall quantification pre‐LVAD surgery, detecting differences in regional wall function. This novel method comprehensively quantifies RV wall function and could complement current pre‐LVAD screening protocols. |
format | Online Article Text |
id | pubmed-9300057 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93000572022-07-21 Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation Bowen, Daniel J. Yalcin, Yunus C. Strachinaru, Mihai McGhie, Jackie S. van den Bosch, Annemien E. Soliman, Osama I. Caliskan, Kadir Echocardiography Original Articles OBJECTIVES: Right ventricular (RV) failure post left ventricular assist device (LVAD) implantation is associated with increased morbidity and mortality. A novel RV multi‐plane imaging method using two‐dimensional echocardiography and electronic plane rotation (MPE) was used to quantify RV function prior to LVAD implantation and to identify potential added value in this patient population. METHODS: In twenty‐five end‐stage heart failure patients (age 58.9 ± 6.8 years, 76% male), systolic function of four different RV walls (lateral, anterior, inferior and inferior coronal) were evaluated from one focussed apical view using MPE. RESULTS: Feasibility of tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular peak systolic velocity (RV‐S') measurements were high (84–100%), with lower TAPSE values measured in the inferior (14.2 ± 4.6 mm) and inferior coronal (12.3 ± 5.0 mm) walls compared to the lateral (16.3 ± 4.5 mm) and anterior walls (16.0 ± 4.5 mm). RV wall longitudinal strain (RV‐LS) measurement was most feasible in the lateral wall (80%; mean: –12.1 ± 4.2%). TAPSE and RV‐LS values were significantly reduced in patients compared to matched healthy individuals (p = <0.001). Seven (28%) patients who developed moderate to severe RV failure (RVF) early post‐implant (≤30 days) had lower pre‐implant values across all multi‐plane parameters compared to those without significant post‐implant RVF, notably four‐wall averaged TAPSE (11.1 ± 3.4 mm vs 15.9 ± 4.0 mm; p = 0.02). CONCLUSION: 2D MPE was highly feasible for RV wall quantification pre‐LVAD surgery, detecting differences in regional wall function. This novel method comprehensively quantifies RV wall function and could complement current pre‐LVAD screening protocols. John Wiley and Sons Inc. 2021-12-08 2022-01 /pmc/articles/PMC9300057/ /pubmed/34877695 http://dx.doi.org/10.1111/echo.15191 Text en © 2021 The Authors. Echocardiography published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Articles Bowen, Daniel J. Yalcin, Yunus C. Strachinaru, Mihai McGhie, Jackie S. van den Bosch, Annemien E. Soliman, Osama I. Caliskan, Kadir Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation |
title | Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation |
title_full | Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation |
title_fullStr | Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation |
title_full_unstemmed | Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation |
title_short | Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation |
title_sort | right ventricular functional assessment by 2d multi‐plane echocardiography prior to left ventricular assist device implantation |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9300057/ https://www.ncbi.nlm.nih.gov/pubmed/34877695 http://dx.doi.org/10.1111/echo.15191 |
work_keys_str_mv | AT bowendanielj rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation AT yalcinyunusc rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation AT strachinarumihai rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation AT mcghiejackies rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation AT vandenboschannemiene rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation AT solimanosamai rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation AT caliskankadir rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation |