Cargando…

Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation

OBJECTIVES: Right ventricular (RV) failure post left ventricular assist device (LVAD) implantation is associated with increased morbidity and mortality. A novel RV multi‐plane imaging method using two‐dimensional echocardiography and electronic plane rotation (MPE) was used to quantify RV function p...

Descripción completa

Detalles Bibliográficos
Autores principales: Bowen, Daniel J., Yalcin, Yunus C., Strachinaru, Mihai, McGhie, Jackie S., van den Bosch, Annemien E., Soliman, Osama I., Caliskan, Kadir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9300057/
https://www.ncbi.nlm.nih.gov/pubmed/34877695
http://dx.doi.org/10.1111/echo.15191
_version_ 1784751121640718336
author Bowen, Daniel J.
Yalcin, Yunus C.
Strachinaru, Mihai
McGhie, Jackie S.
van den Bosch, Annemien E.
Soliman, Osama I.
Caliskan, Kadir
author_facet Bowen, Daniel J.
Yalcin, Yunus C.
Strachinaru, Mihai
McGhie, Jackie S.
van den Bosch, Annemien E.
Soliman, Osama I.
Caliskan, Kadir
author_sort Bowen, Daniel J.
collection PubMed
description OBJECTIVES: Right ventricular (RV) failure post left ventricular assist device (LVAD) implantation is associated with increased morbidity and mortality. A novel RV multi‐plane imaging method using two‐dimensional echocardiography and electronic plane rotation (MPE) was used to quantify RV function prior to LVAD implantation and to identify potential added value in this patient population. METHODS: In twenty‐five end‐stage heart failure patients (age 58.9 ± 6.8 years, 76% male), systolic function of four different RV walls (lateral, anterior, inferior and inferior coronal) were evaluated from one focussed apical view using MPE. RESULTS: Feasibility of tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular peak systolic velocity (RV‐S') measurements were high (84–100%), with lower TAPSE values measured in the inferior (14.2 ± 4.6 mm) and inferior coronal (12.3 ± 5.0 mm) walls compared to the lateral (16.3 ± 4.5 mm) and anterior walls (16.0 ± 4.5 mm). RV wall longitudinal strain (RV‐LS) measurement was most feasible in the lateral wall (80%; mean: –12.1 ± 4.2%). TAPSE and RV‐LS values were significantly reduced in patients compared to matched healthy individuals (p = <0.001). Seven (28%) patients who developed moderate to severe RV failure (RVF) early post‐implant (≤30 days) had lower pre‐implant values across all multi‐plane parameters compared to those without significant post‐implant RVF, notably four‐wall averaged TAPSE (11.1 ± 3.4 mm vs 15.9 ± 4.0 mm; p = 0.02). CONCLUSION: 2D MPE was highly feasible for RV wall quantification pre‐LVAD surgery, detecting differences in regional wall function. This novel method comprehensively quantifies RV wall function and could complement current pre‐LVAD screening protocols.
format Online
Article
Text
id pubmed-9300057
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-93000572022-07-21 Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation Bowen, Daniel J. Yalcin, Yunus C. Strachinaru, Mihai McGhie, Jackie S. van den Bosch, Annemien E. Soliman, Osama I. Caliskan, Kadir Echocardiography Original Articles OBJECTIVES: Right ventricular (RV) failure post left ventricular assist device (LVAD) implantation is associated with increased morbidity and mortality. A novel RV multi‐plane imaging method using two‐dimensional echocardiography and electronic plane rotation (MPE) was used to quantify RV function prior to LVAD implantation and to identify potential added value in this patient population. METHODS: In twenty‐five end‐stage heart failure patients (age 58.9 ± 6.8 years, 76% male), systolic function of four different RV walls (lateral, anterior, inferior and inferior coronal) were evaluated from one focussed apical view using MPE. RESULTS: Feasibility of tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular peak systolic velocity (RV‐S') measurements were high (84–100%), with lower TAPSE values measured in the inferior (14.2 ± 4.6 mm) and inferior coronal (12.3 ± 5.0 mm) walls compared to the lateral (16.3 ± 4.5 mm) and anterior walls (16.0 ± 4.5 mm). RV wall longitudinal strain (RV‐LS) measurement was most feasible in the lateral wall (80%; mean: –12.1 ± 4.2%). TAPSE and RV‐LS values were significantly reduced in patients compared to matched healthy individuals (p = <0.001). Seven (28%) patients who developed moderate to severe RV failure (RVF) early post‐implant (≤30 days) had lower pre‐implant values across all multi‐plane parameters compared to those without significant post‐implant RVF, notably four‐wall averaged TAPSE (11.1 ± 3.4 mm vs 15.9 ± 4.0 mm; p = 0.02). CONCLUSION: 2D MPE was highly feasible for RV wall quantification pre‐LVAD surgery, detecting differences in regional wall function. This novel method comprehensively quantifies RV wall function and could complement current pre‐LVAD screening protocols. John Wiley and Sons Inc. 2021-12-08 2022-01 /pmc/articles/PMC9300057/ /pubmed/34877695 http://dx.doi.org/10.1111/echo.15191 Text en © 2021 The Authors. Echocardiography published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Bowen, Daniel J.
Yalcin, Yunus C.
Strachinaru, Mihai
McGhie, Jackie S.
van den Bosch, Annemien E.
Soliman, Osama I.
Caliskan, Kadir
Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation
title Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation
title_full Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation
title_fullStr Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation
title_full_unstemmed Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation
title_short Right ventricular functional assessment by 2D multi‐plane echocardiography prior to left ventricular assist device implantation
title_sort right ventricular functional assessment by 2d multi‐plane echocardiography prior to left ventricular assist device implantation
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9300057/
https://www.ncbi.nlm.nih.gov/pubmed/34877695
http://dx.doi.org/10.1111/echo.15191
work_keys_str_mv AT bowendanielj rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation
AT yalcinyunusc rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation
AT strachinarumihai rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation
AT mcghiejackies rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation
AT vandenboschannemiene rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation
AT solimanosamai rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation
AT caliskankadir rightventricularfunctionalassessmentby2dmultiplaneechocardiographypriortoleftventricularassistdeviceimplantation