Cargando…

Monthly measurement of high‐sensitivity cardiac troponins T and creatine kinase in asymptomatic chronic hemodialysis patients: A one‐year prospective study

BACKGROUND: Cardiology guidelines recommend measuring high‐sensitivity cardiac troponin (hs‐cTn) for the diagnostic work‐up of acute coronary syndromes (ACS). Many hospitals measure hs‐cTnT, but preliminary data have shown that hs‐cTnT is higher than normal in many hemodialysis patients without evid...

Descripción completa

Detalles Bibliográficos
Autores principales: Gremaud, Stéphane, Fellay, Benoît, Hemett, Ould Maouloud, Magnin, Jean‐Luc, Descombes, Eric
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9300151/
https://www.ncbi.nlm.nih.gov/pubmed/34897965
http://dx.doi.org/10.1111/hdi.12985
_version_ 1784751145760063488
author Gremaud, Stéphane
Fellay, Benoît
Hemett, Ould Maouloud
Magnin, Jean‐Luc
Descombes, Eric
author_facet Gremaud, Stéphane
Fellay, Benoît
Hemett, Ould Maouloud
Magnin, Jean‐Luc
Descombes, Eric
author_sort Gremaud, Stéphane
collection PubMed
description BACKGROUND: Cardiology guidelines recommend measuring high‐sensitivity cardiac troponin (hs‐cTn) for the diagnostic work‐up of acute coronary syndromes (ACS). Many hospitals measure hs‐cTnT, but preliminary data have shown that hs‐cTnT is higher than normal in many hemodialysis patients without evidence of ACS. The purpose of this study was therefore to determine the hs‐cTnT levels every month for 1 year in asymptomatic hemodialysis patients, in order to assess their changes over time relative to creatine kinase. METHODS: Fourty‐four hemodialysis patients (mean age 67 ± 14 years) were included. The predialysis levels of fifth‐generation hs‐cTnT, CK, and CK‐MB were measured every month for 1 year using a Cobas® 6000 analyzer (Roche Diagnostics, Switzerland). RESULTS: Almost 100% of hs‐cTnT measurements were higher than normal (N < 14 ng/L); the mean ± SD annual level was 84 ± 59 ng/L, ranging from a minimum of 24 ± 2 to 241 ± 28 ng/L in individual patients. The mean levels of CK and CK‐MB were normal. Thirteen myocardial infarctions were analyzed, which were all associated with an initial elevation in hs‐cTnT >45% from the individual baseline value. By comparison, CK and CK‐MB only increased in 38% and 31% of these myocardial infarctions, respectively. DISCUSSION: hs‐cTnT is persistently higher than normal in chronic hemodialysis patients. Standard algorithms for diagnosing ACS can obviously not be used and alternative diagnostic strategies need to be developed. According to our data, and given the huge variation in baseline hs‐cTnT levels among patients, the use of higher cut‐offs as proposed in the literature cannot be recommended. Instead, we consider that hs‐cTnT should be checked at regular intervals (e.g., every 3–6 months) in order to establish individual baseline levels for hs‐cTnT. This approach, in most instances, not only makes it possible to more rapidly rule‐in but also to rapidly rule‐out, cases of ACS in hemodialysis patients who develop cardiac symptoms.
format Online
Article
Text
id pubmed-9300151
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-93001512022-07-21 Monthly measurement of high‐sensitivity cardiac troponins T and creatine kinase in asymptomatic chronic hemodialysis patients: A one‐year prospective study Gremaud, Stéphane Fellay, Benoît Hemett, Ould Maouloud Magnin, Jean‐Luc Descombes, Eric Hemodial Int Original Articles BACKGROUND: Cardiology guidelines recommend measuring high‐sensitivity cardiac troponin (hs‐cTn) for the diagnostic work‐up of acute coronary syndromes (ACS). Many hospitals measure hs‐cTnT, but preliminary data have shown that hs‐cTnT is higher than normal in many hemodialysis patients without evidence of ACS. The purpose of this study was therefore to determine the hs‐cTnT levels every month for 1 year in asymptomatic hemodialysis patients, in order to assess their changes over time relative to creatine kinase. METHODS: Fourty‐four hemodialysis patients (mean age 67 ± 14 years) were included. The predialysis levels of fifth‐generation hs‐cTnT, CK, and CK‐MB were measured every month for 1 year using a Cobas® 6000 analyzer (Roche Diagnostics, Switzerland). RESULTS: Almost 100% of hs‐cTnT measurements were higher than normal (N < 14 ng/L); the mean ± SD annual level was 84 ± 59 ng/L, ranging from a minimum of 24 ± 2 to 241 ± 28 ng/L in individual patients. The mean levels of CK and CK‐MB were normal. Thirteen myocardial infarctions were analyzed, which were all associated with an initial elevation in hs‐cTnT >45% from the individual baseline value. By comparison, CK and CK‐MB only increased in 38% and 31% of these myocardial infarctions, respectively. DISCUSSION: hs‐cTnT is persistently higher than normal in chronic hemodialysis patients. Standard algorithms for diagnosing ACS can obviously not be used and alternative diagnostic strategies need to be developed. According to our data, and given the huge variation in baseline hs‐cTnT levels among patients, the use of higher cut‐offs as proposed in the literature cannot be recommended. Instead, we consider that hs‐cTnT should be checked at regular intervals (e.g., every 3–6 months) in order to establish individual baseline levels for hs‐cTnT. This approach, in most instances, not only makes it possible to more rapidly rule‐in but also to rapidly rule‐out, cases of ACS in hemodialysis patients who develop cardiac symptoms. John Wiley & Sons, Inc. 2021-12-13 2022-04 /pmc/articles/PMC9300151/ /pubmed/34897965 http://dx.doi.org/10.1111/hdi.12985 Text en © 2021 The Authors. Hemodialysis International published by Wiley Periodicals LLC on behalf of International Society for Hemodialysis. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Gremaud, Stéphane
Fellay, Benoît
Hemett, Ould Maouloud
Magnin, Jean‐Luc
Descombes, Eric
Monthly measurement of high‐sensitivity cardiac troponins T and creatine kinase in asymptomatic chronic hemodialysis patients: A one‐year prospective study
title Monthly measurement of high‐sensitivity cardiac troponins T and creatine kinase in asymptomatic chronic hemodialysis patients: A one‐year prospective study
title_full Monthly measurement of high‐sensitivity cardiac troponins T and creatine kinase in asymptomatic chronic hemodialysis patients: A one‐year prospective study
title_fullStr Monthly measurement of high‐sensitivity cardiac troponins T and creatine kinase in asymptomatic chronic hemodialysis patients: A one‐year prospective study
title_full_unstemmed Monthly measurement of high‐sensitivity cardiac troponins T and creatine kinase in asymptomatic chronic hemodialysis patients: A one‐year prospective study
title_short Monthly measurement of high‐sensitivity cardiac troponins T and creatine kinase in asymptomatic chronic hemodialysis patients: A one‐year prospective study
title_sort monthly measurement of high‐sensitivity cardiac troponins t and creatine kinase in asymptomatic chronic hemodialysis patients: a one‐year prospective study
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9300151/
https://www.ncbi.nlm.nih.gov/pubmed/34897965
http://dx.doi.org/10.1111/hdi.12985
work_keys_str_mv AT gremaudstephane monthlymeasurementofhighsensitivitycardiactroponinstandcreatinekinaseinasymptomaticchronichemodialysispatientsaoneyearprospectivestudy
AT fellaybenoit monthlymeasurementofhighsensitivitycardiactroponinstandcreatinekinaseinasymptomaticchronichemodialysispatientsaoneyearprospectivestudy
AT hemettouldmaouloud monthlymeasurementofhighsensitivitycardiactroponinstandcreatinekinaseinasymptomaticchronichemodialysispatientsaoneyearprospectivestudy
AT magninjeanluc monthlymeasurementofhighsensitivitycardiactroponinstandcreatinekinaseinasymptomaticchronichemodialysispatientsaoneyearprospectivestudy
AT descombeseric monthlymeasurementofhighsensitivitycardiactroponinstandcreatinekinaseinasymptomaticchronichemodialysispatientsaoneyearprospectivestudy