Cargando…

Ultrasonic cleaning is effective in removing carbonized clots and tissue from the insulation‐tipped diathermic knife‐2

OBJECTIVES: Since carbonized clots and tissue (debris) tend to adhere firmly to the tip of the endoscopic submucosal dissection (ESD) knife as the procedure proceeds, manual removing the firm debris is often challenging and time‐consuming. Recently, effective ultrasonic cleaning for other medical de...

Descripción completa

Detalles Bibliográficos
Autores principales: Murakami, Kei, Hirata, Daizen, Haraguchi, Kengo, Arai, Noriko, Inoue, Koji, Miyazaki, Yuka, Funase, Kimihiro, Nakashige, Tadao, Teramoto, Akira, Iwatate, Mineo, Hattori, Santa, Fujita, Mikio, Sano, Wataru, Sano, Yasushi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9302054/
https://www.ncbi.nlm.nih.gov/pubmed/35873510
http://dx.doi.org/10.1002/deo2.101
_version_ 1784751552729186304
author Murakami, Kei
Hirata, Daizen
Haraguchi, Kengo
Arai, Noriko
Inoue, Koji
Miyazaki, Yuka
Funase, Kimihiro
Nakashige, Tadao
Teramoto, Akira
Iwatate, Mineo
Hattori, Santa
Fujita, Mikio
Sano, Wataru
Sano, Yasushi
author_facet Murakami, Kei
Hirata, Daizen
Haraguchi, Kengo
Arai, Noriko
Inoue, Koji
Miyazaki, Yuka
Funase, Kimihiro
Nakashige, Tadao
Teramoto, Akira
Iwatate, Mineo
Hattori, Santa
Fujita, Mikio
Sano, Wataru
Sano, Yasushi
author_sort Murakami, Kei
collection PubMed
description OBJECTIVES: Since carbonized clots and tissue (debris) tend to adhere firmly to the tip of the endoscopic submucosal dissection (ESD) knife as the procedure proceeds, manual removing the firm debris is often challenging and time‐consuming. Recently, effective ultrasonic cleaning for other medical devices has been reported. The aim of the present study was to clarify whether ultrasonic cleaning is effective in removing the debris on the insulation‐tipped diathermic (IT) knife‐2. METHODS: This study was an ex‐vivo experimental randomized study. A total of 40 IT knife‐2 knives with debris on their tip surfaces were prepared and randomly assigned to two groups (Group A and Group B). The knives in Group A were cleaned using the conventional scrubbing method for 30 s (conventional cleaning method), while those in Group B were cleaned using a combined method of scrubbing for 20 s and ultrasonic cleaning for 10 s (combined ultrasonic cleaning method). The tip electrode of the knife after cleaning was photographed under a microscope (40x). The 40 images of the knives were evaluated by independent three endoscopists and two clinical engineers using the five‐step evaluation criteria ranging from cleaning score 1 (dirty) to 5 (clean). RESULTS: The mean cleaning score of 3.78 (range: 2.33–4.67) in Group B was significantly higher than that of 1.68 (range: 1.00–2.83) in Group A. CONCLUSIONS: The combined ultrasonic cleaning method could remove debris adhering to the IT knife‐2 more effectively than the conventional cleaning method. Ultrasonic cleaning may be applied for real‐world ESD.
format Online
Article
Text
id pubmed-9302054
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-93020542022-07-22 Ultrasonic cleaning is effective in removing carbonized clots and tissue from the insulation‐tipped diathermic knife‐2 Murakami, Kei Hirata, Daizen Haraguchi, Kengo Arai, Noriko Inoue, Koji Miyazaki, Yuka Funase, Kimihiro Nakashige, Tadao Teramoto, Akira Iwatate, Mineo Hattori, Santa Fujita, Mikio Sano, Wataru Sano, Yasushi DEN Open Original Articles OBJECTIVES: Since carbonized clots and tissue (debris) tend to adhere firmly to the tip of the endoscopic submucosal dissection (ESD) knife as the procedure proceeds, manual removing the firm debris is often challenging and time‐consuming. Recently, effective ultrasonic cleaning for other medical devices has been reported. The aim of the present study was to clarify whether ultrasonic cleaning is effective in removing the debris on the insulation‐tipped diathermic (IT) knife‐2. METHODS: This study was an ex‐vivo experimental randomized study. A total of 40 IT knife‐2 knives with debris on their tip surfaces were prepared and randomly assigned to two groups (Group A and Group B). The knives in Group A were cleaned using the conventional scrubbing method for 30 s (conventional cleaning method), while those in Group B were cleaned using a combined method of scrubbing for 20 s and ultrasonic cleaning for 10 s (combined ultrasonic cleaning method). The tip electrode of the knife after cleaning was photographed under a microscope (40x). The 40 images of the knives were evaluated by independent three endoscopists and two clinical engineers using the five‐step evaluation criteria ranging from cleaning score 1 (dirty) to 5 (clean). RESULTS: The mean cleaning score of 3.78 (range: 2.33–4.67) in Group B was significantly higher than that of 1.68 (range: 1.00–2.83) in Group A. CONCLUSIONS: The combined ultrasonic cleaning method could remove debris adhering to the IT knife‐2 more effectively than the conventional cleaning method. Ultrasonic cleaning may be applied for real‐world ESD. John Wiley and Sons Inc. 2022-03-06 /pmc/articles/PMC9302054/ /pubmed/35873510 http://dx.doi.org/10.1002/deo2.101 Text en © 2022 The Authors. DEN Open published by John Wiley & Sons Australia, Ltd on behalf of Japan Gastroenterological Endoscopy Society https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Murakami, Kei
Hirata, Daizen
Haraguchi, Kengo
Arai, Noriko
Inoue, Koji
Miyazaki, Yuka
Funase, Kimihiro
Nakashige, Tadao
Teramoto, Akira
Iwatate, Mineo
Hattori, Santa
Fujita, Mikio
Sano, Wataru
Sano, Yasushi
Ultrasonic cleaning is effective in removing carbonized clots and tissue from the insulation‐tipped diathermic knife‐2
title Ultrasonic cleaning is effective in removing carbonized clots and tissue from the insulation‐tipped diathermic knife‐2
title_full Ultrasonic cleaning is effective in removing carbonized clots and tissue from the insulation‐tipped diathermic knife‐2
title_fullStr Ultrasonic cleaning is effective in removing carbonized clots and tissue from the insulation‐tipped diathermic knife‐2
title_full_unstemmed Ultrasonic cleaning is effective in removing carbonized clots and tissue from the insulation‐tipped diathermic knife‐2
title_short Ultrasonic cleaning is effective in removing carbonized clots and tissue from the insulation‐tipped diathermic knife‐2
title_sort ultrasonic cleaning is effective in removing carbonized clots and tissue from the insulation‐tipped diathermic knife‐2
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9302054/
https://www.ncbi.nlm.nih.gov/pubmed/35873510
http://dx.doi.org/10.1002/deo2.101
work_keys_str_mv AT murakamikei ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT hiratadaizen ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT haraguchikengo ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT arainoriko ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT inouekoji ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT miyazakiyuka ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT funasekimihiro ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT nakashigetadao ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT teramotoakira ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT iwatatemineo ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT hattorisanta ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT fujitamikio ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT sanowataru ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2
AT sanoyasushi ultrasoniccleaningiseffectiveinremovingcarbonizedclotsandtissuefromtheinsulationtippeddiathermicknife2