Cargando…
Hemolytic anemia caused by an excessively kinked prosthetic graft after total arch replacement detected by 4-dimensional flow magnetic resonance imaging: A case report
Hemolytic anemia is a rare postoperative complication of aortic surgery, which may be caused by an excessively kinked graft that causes abnormal blood flow. It has been reported that 4-dimensional flow magnetic resonance imaging (4D flow MRI) can identify abnormal flow. Herein, we report the guidanc...
Autores principales: | Takei, Yusuke, Shibasaki, Ikuko, Suzuki, Kohei, Miyazaki, Shohei, Hirota, Shotaro, Ohashi, Hirotaka, Saito, Shunsuke, Fukuda, Hirotsugu |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Lippincott Williams & Wilkins
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9302348/ https://www.ncbi.nlm.nih.gov/pubmed/35866824 http://dx.doi.org/10.1097/MD.0000000000029617 |
Ejemplares similares
-
Modified Total Arch Debranching TEVAR with Aberrant Left Vertebral Artery
por: Takei, Yusuke, et al.
Publicado: (2018) -
Prosthetic Valve Function after Aortic Valve Replacement for Severe Aortic Stenosis by Transcatheter Procedure versus Surgery
por: Saito, Shunsuke, et al.
Publicado: (2022) -
A protocol-based treatment for ruptured abdominal aortic aneurysm contributed to improving aorta-related mortality: a retrospective cohort study
por: Takei, Yusuke, et al.
Publicado: (2023) -
Hemolytic Anemia Caused by Kinking of Dacron Grafts Implanted in Repair of after Aortic Dissection
por: Sabzi, Feridoun, et al.
Publicado: (2016) -
Hemolytic anemia caused by kinked graft 6 months after aortic dissection repair
por: Tamura, Kazuki, et al.
Publicado: (2022)