Cargando…

Precision and trueness of computer‐assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis

OBJECTIVES: The aim of this in vitro study was to determine accuracy defined by trueness and precision of computer‐assisted implant surgery comparing two guided surgery kits designed for either closed sleeves or open sleeves with a lateral window. MATERIAL AND METHODS: Each n=20 implants were placed...

Descripción completa

Detalles Bibliográficos
Autores principales: Guentsch, Arndt, An, Hongseok, Dentino, Andrew R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9302989/
https://www.ncbi.nlm.nih.gov/pubmed/35148444
http://dx.doi.org/10.1111/clr.13904
_version_ 1784751753515761664
author Guentsch, Arndt
An, Hongseok
Dentino, Andrew R.
author_facet Guentsch, Arndt
An, Hongseok
Dentino, Andrew R.
author_sort Guentsch, Arndt
collection PubMed
description OBJECTIVES: The aim of this in vitro study was to determine accuracy defined by trueness and precision of computer‐assisted implant surgery comparing two guided surgery kits designed for either closed sleeves or open sleeves with a lateral window. MATERIAL AND METHODS: Each n=20 implants were placed fully guided (sleeve‐bone distance of 2 or 4 mm) in identical replicas using a surgical guide with both closed sleeve or an open sleeve, partially guided, or free hand. The achieved implant position was digitized and compared with the planned position. Trueness and precision were determined. The angular deviation was defined as the primary outcome parameter. The means, standard deviation, and 95%‐confidence intervals were analyzed statistically with 1‐way ANOVA and the Scheffé procedure. RESULTS: The accuracy of guided implant placement using closed and open sleeves was comparable when the sleeve‐bone distance was 2 mm. Accuracy decreased when the sleeve‐bone distance increased in both fully guided groups, more so in the open than in the closed sleeve group. The least accurate method was the free‐hand group. Partially guided implant surgery was more accurate than free‐hand placement, but less accurate than the fully guided groups with 2‐mm sleeve‐bone distance. CONCLUSIONS: The closer the sleeve to the bone, the more accurate and precise is computer‐assisted implant surgery using a closed system and a system using open sleeves. Partially guided implant surgery using only the static guide for the pilot drill is less accurate than both fully guided approaches, but more accurate than free‐hand surgery.
format Online
Article
Text
id pubmed-9302989
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-93029892022-07-22 Precision and trueness of computer‐assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis Guentsch, Arndt An, Hongseok Dentino, Andrew R. Clin Oral Implants Res Original Articles OBJECTIVES: The aim of this in vitro study was to determine accuracy defined by trueness and precision of computer‐assisted implant surgery comparing two guided surgery kits designed for either closed sleeves or open sleeves with a lateral window. MATERIAL AND METHODS: Each n=20 implants were placed fully guided (sleeve‐bone distance of 2 or 4 mm) in identical replicas using a surgical guide with both closed sleeve or an open sleeve, partially guided, or free hand. The achieved implant position was digitized and compared with the planned position. Trueness and precision were determined. The angular deviation was defined as the primary outcome parameter. The means, standard deviation, and 95%‐confidence intervals were analyzed statistically with 1‐way ANOVA and the Scheffé procedure. RESULTS: The accuracy of guided implant placement using closed and open sleeves was comparable when the sleeve‐bone distance was 2 mm. Accuracy decreased when the sleeve‐bone distance increased in both fully guided groups, more so in the open than in the closed sleeve group. The least accurate method was the free‐hand group. Partially guided implant surgery was more accurate than free‐hand placement, but less accurate than the fully guided groups with 2‐mm sleeve‐bone distance. CONCLUSIONS: The closer the sleeve to the bone, the more accurate and precise is computer‐assisted implant surgery using a closed system and a system using open sleeves. Partially guided implant surgery using only the static guide for the pilot drill is less accurate than both fully guided approaches, but more accurate than free‐hand surgery. John Wiley and Sons Inc. 2022-02-19 2022-04 /pmc/articles/PMC9302989/ /pubmed/35148444 http://dx.doi.org/10.1111/clr.13904 Text en © 2022 The Authors. Clinical Oral Implants Research published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Articles
Guentsch, Arndt
An, Hongseok
Dentino, Andrew R.
Precision and trueness of computer‐assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis
title Precision and trueness of computer‐assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis
title_full Precision and trueness of computer‐assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis
title_fullStr Precision and trueness of computer‐assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis
title_full_unstemmed Precision and trueness of computer‐assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis
title_short Precision and trueness of computer‐assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis
title_sort precision and trueness of computer‐assisted implant placement using static surgical guides with open and closed sleeves: an in vitro analysis
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9302989/
https://www.ncbi.nlm.nih.gov/pubmed/35148444
http://dx.doi.org/10.1111/clr.13904
work_keys_str_mv AT guentscharndt precisionandtruenessofcomputerassistedimplantplacementusingstaticsurgicalguideswithopenandclosedsleevesaninvitroanalysis
AT anhongseok precisionandtruenessofcomputerassistedimplantplacementusingstaticsurgicalguideswithopenandclosedsleevesaninvitroanalysis
AT dentinoandrewr precisionandtruenessofcomputerassistedimplantplacementusingstaticsurgicalguideswithopenandclosedsleevesaninvitroanalysis