Cargando…

Evaluation of the short‐term host response and biomechanics of an absorbable poly‐4‐hydroxybutyrate scaffold in a sheep model following vaginal implantation

OBJECTIVE: To evaluate the host‐ and biomechanical response to a fully absorbable poly‐4‐hydroxybutyrate (P4HB) scaffold in comparison with the response to polypropylene (PP) mesh. DESIGN: In vivo animal experiment. SETTING: KU Leuven Center for Surgical Technologies. POPULATION: Fourteen parous fem...

Descripción completa

Detalles Bibliográficos
Autores principales: Diedrich, Chantal M., Guler, Zeliha, Hympanova, Lucie, Vodegel, Eva, Zündel, Manuel, Mazza, Edoardo, Deprest, Jan, Roovers, Jan Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9303173/
https://www.ncbi.nlm.nih.gov/pubmed/34865300
http://dx.doi.org/10.1111/1471-0528.17040
Descripción
Sumario:OBJECTIVE: To evaluate the host‐ and biomechanical response to a fully absorbable poly‐4‐hydroxybutyrate (P4HB) scaffold in comparison with the response to polypropylene (PP) mesh. DESIGN: In vivo animal experiment. SETTING: KU Leuven Center for Surgical Technologies. POPULATION: Fourteen parous female Mule sheep. METHODS: P4HB scaffolds were surgically implanted in the posterior vaginal wall of sheep. The comparative PP mesh data were obtained from an identical study protocol performed previously. MAIN OUTCOME MEASURES: Gross necropsy, host response and biomechanical evaluation of explants, and the in vivo P4HB scaffold degradation were evaluated at 60‐ and 180‐days post‐implantation. Data are reported as mean ± standard deviation (SD) or standard error of the mean (SEM). RESULTS: Gross necropsy revealed no implant‐related adverse events using P4HB scaffolds. The tensile stiffness of the P4HB explants increased at 180‐days (12.498 ± 2.66 N/mm SEM [p =0.019]) as compared to 60‐days (4.585 ± 1.57 N/mm) post‐implantation, while P4HB degraded gradually. P4HB scaffolds exhibited excellent tissue integration with dense connective tissue and a moderate initial host response. P4HB scaffolds induced a significantly higher M2/M1 ratio (1.70 ± 0.67 SD, score 0–4), as compared to PP mesh(0.99 ± 0.78 SD, score 0–4) at 180‐days. CONCLUSIONS: P4HB scaffold facilitated a gradual load transfer to vaginal tissue over time. The fully absorbable P4HB scaffold, in comparison to PP mesh, has a favorable host response with comparable load‐bearing capacity. If these results are also observed at longer follow‐up in‐vivo, a clinical study using P4HB for vaginal POP surgery may be warranted to demonstrate efficacy. TWEETABLE ABSTRACT: Degradable vaginal P4HB implant might be a solution for treatment of POP.