Cargando…

The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study

BACKGROUND: Onyx is frequently used for endovascular embolization of intracranial arteriovenous malformations (AVMs) and dural arteriovenous fistulas (dAVFs). One drawback of using Onyx is the generation of artifacts in cone-beam CT (CBCT). These artifacts can represent an obstacle for the detection...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmitt, Niclas, Weyland, Charlotte S, Wucherpfennig, Lena, Sommer, Christof M, Bendszus, Martin, Möhlenbruch, Markus A, Vollherbst, Dominik F
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9304113/
https://www.ncbi.nlm.nih.gov/pubmed/34433643
http://dx.doi.org/10.1136/neurintsurg-2021-018018
_version_ 1784752027601993728
author Schmitt, Niclas
Weyland, Charlotte S
Wucherpfennig, Lena
Sommer, Christof M
Bendszus, Martin
Möhlenbruch, Markus A
Vollherbst, Dominik F
author_facet Schmitt, Niclas
Weyland, Charlotte S
Wucherpfennig, Lena
Sommer, Christof M
Bendszus, Martin
Möhlenbruch, Markus A
Vollherbst, Dominik F
author_sort Schmitt, Niclas
collection PubMed
description BACKGROUND: Onyx is frequently used for endovascular embolization of intracranial arteriovenous malformations (AVMs) and dural arteriovenous fistulas (dAVFs). One drawback of using Onyx is the generation of artifacts in cone-beam CT (CBCT). These artifacts can represent an obstacle for the detection of periprocedural hemorrhage or planning of subsequent radiosurgery. This study investigates the effect of artifact reduction by the syngo DynaCT SMART Metal Artifact Reduction (MAR) software. METHODS: A standardized in vitro tube model (n=10) was filled with Onyx 18 and CBCT image acquisition was conducted in a brain imaging phantom. Furthermore, post-interventional CBCT images of 20 patients with AVM (n=13) or dAVF (n=7), each treated with Onyx, were investigated. The MAR software was applied for artifact reduction. Artifacts of the original and the post-processed images were analyzed quantitatively (standard deviation in a region of interest on the layer providing the most artifacts) and qualitatively. For the patient images, the effect of the MAR software on brain parenchyma on artifact-free images was further investigated. RESULTS: Quantitative and qualitative analyses of both datasets demonstrated a lower degree of artifacts in the post-processed images (eg, patient images: 38.30±22.03 density units (no MAR; mean SD±SD) vs 19.83±12.31 density units (with MAR; p<0.001). The MAR software had no influence on the brain parenchyma in artifact-free images. CONCLUSION: The MAR software significantly reduced the artifacts evoked by Onyx in CBCT without affecting the visualization of brain parenchyma on artifact-free images. Applying this software could thus improve the quality of periprocedural CBCT images after embolization with Onyx.
format Online
Article
Text
id pubmed-9304113
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-93041132022-08-11 The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study Schmitt, Niclas Weyland, Charlotte S Wucherpfennig, Lena Sommer, Christof M Bendszus, Martin Möhlenbruch, Markus A Vollherbst, Dominik F J Neurointerv Surg Neuroimaging BACKGROUND: Onyx is frequently used for endovascular embolization of intracranial arteriovenous malformations (AVMs) and dural arteriovenous fistulas (dAVFs). One drawback of using Onyx is the generation of artifacts in cone-beam CT (CBCT). These artifacts can represent an obstacle for the detection of periprocedural hemorrhage or planning of subsequent radiosurgery. This study investigates the effect of artifact reduction by the syngo DynaCT SMART Metal Artifact Reduction (MAR) software. METHODS: A standardized in vitro tube model (n=10) was filled with Onyx 18 and CBCT image acquisition was conducted in a brain imaging phantom. Furthermore, post-interventional CBCT images of 20 patients with AVM (n=13) or dAVF (n=7), each treated with Onyx, were investigated. The MAR software was applied for artifact reduction. Artifacts of the original and the post-processed images were analyzed quantitatively (standard deviation in a region of interest on the layer providing the most artifacts) and qualitatively. For the patient images, the effect of the MAR software on brain parenchyma on artifact-free images was further investigated. RESULTS: Quantitative and qualitative analyses of both datasets demonstrated a lower degree of artifacts in the post-processed images (eg, patient images: 38.30±22.03 density units (no MAR; mean SD±SD) vs 19.83±12.31 density units (with MAR; p<0.001). The MAR software had no influence on the brain parenchyma in artifact-free images. CONCLUSION: The MAR software significantly reduced the artifacts evoked by Onyx in CBCT without affecting the visualization of brain parenchyma on artifact-free images. Applying this software could thus improve the quality of periprocedural CBCT images after embolization with Onyx. BMJ Publishing Group 2022-08 2021-08-25 /pmc/articles/PMC9304113/ /pubmed/34433643 http://dx.doi.org/10.1136/neurintsurg-2021-018018 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Neuroimaging
Schmitt, Niclas
Weyland, Charlotte S
Wucherpfennig, Lena
Sommer, Christof M
Bendszus, Martin
Möhlenbruch, Markus A
Vollherbst, Dominik F
The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study
title The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study
title_full The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study
title_fullStr The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study
title_full_unstemmed The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study
title_short The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study
title_sort impact of software-based metal artifact reduction on the liquid embolic agent onyx in cone-beam ct: a systematic in vitro and in vivo study
topic Neuroimaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9304113/
https://www.ncbi.nlm.nih.gov/pubmed/34433643
http://dx.doi.org/10.1136/neurintsurg-2021-018018
work_keys_str_mv AT schmittniclas theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT weylandcharlottes theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT wucherpfenniglena theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT sommerchristofm theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT bendszusmartin theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT mohlenbruchmarkusa theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT vollherbstdominikf theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT schmittniclas impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT weylandcharlottes impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT wucherpfenniglena impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT sommerchristofm impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT bendszusmartin impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT mohlenbruchmarkusa impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy
AT vollherbstdominikf impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy