Cargando…
The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study
BACKGROUND: Onyx is frequently used for endovascular embolization of intracranial arteriovenous malformations (AVMs) and dural arteriovenous fistulas (dAVFs). One drawback of using Onyx is the generation of artifacts in cone-beam CT (CBCT). These artifacts can represent an obstacle for the detection...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9304113/ https://www.ncbi.nlm.nih.gov/pubmed/34433643 http://dx.doi.org/10.1136/neurintsurg-2021-018018 |
_version_ | 1784752027601993728 |
---|---|
author | Schmitt, Niclas Weyland, Charlotte S Wucherpfennig, Lena Sommer, Christof M Bendszus, Martin Möhlenbruch, Markus A Vollherbst, Dominik F |
author_facet | Schmitt, Niclas Weyland, Charlotte S Wucherpfennig, Lena Sommer, Christof M Bendszus, Martin Möhlenbruch, Markus A Vollherbst, Dominik F |
author_sort | Schmitt, Niclas |
collection | PubMed |
description | BACKGROUND: Onyx is frequently used for endovascular embolization of intracranial arteriovenous malformations (AVMs) and dural arteriovenous fistulas (dAVFs). One drawback of using Onyx is the generation of artifacts in cone-beam CT (CBCT). These artifacts can represent an obstacle for the detection of periprocedural hemorrhage or planning of subsequent radiosurgery. This study investigates the effect of artifact reduction by the syngo DynaCT SMART Metal Artifact Reduction (MAR) software. METHODS: A standardized in vitro tube model (n=10) was filled with Onyx 18 and CBCT image acquisition was conducted in a brain imaging phantom. Furthermore, post-interventional CBCT images of 20 patients with AVM (n=13) or dAVF (n=7), each treated with Onyx, were investigated. The MAR software was applied for artifact reduction. Artifacts of the original and the post-processed images were analyzed quantitatively (standard deviation in a region of interest on the layer providing the most artifacts) and qualitatively. For the patient images, the effect of the MAR software on brain parenchyma on artifact-free images was further investigated. RESULTS: Quantitative and qualitative analyses of both datasets demonstrated a lower degree of artifacts in the post-processed images (eg, patient images: 38.30±22.03 density units (no MAR; mean SD±SD) vs 19.83±12.31 density units (with MAR; p<0.001). The MAR software had no influence on the brain parenchyma in artifact-free images. CONCLUSION: The MAR software significantly reduced the artifacts evoked by Onyx in CBCT without affecting the visualization of brain parenchyma on artifact-free images. Applying this software could thus improve the quality of periprocedural CBCT images after embolization with Onyx. |
format | Online Article Text |
id | pubmed-9304113 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-93041132022-08-11 The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study Schmitt, Niclas Weyland, Charlotte S Wucherpfennig, Lena Sommer, Christof M Bendszus, Martin Möhlenbruch, Markus A Vollherbst, Dominik F J Neurointerv Surg Neuroimaging BACKGROUND: Onyx is frequently used for endovascular embolization of intracranial arteriovenous malformations (AVMs) and dural arteriovenous fistulas (dAVFs). One drawback of using Onyx is the generation of artifacts in cone-beam CT (CBCT). These artifacts can represent an obstacle for the detection of periprocedural hemorrhage or planning of subsequent radiosurgery. This study investigates the effect of artifact reduction by the syngo DynaCT SMART Metal Artifact Reduction (MAR) software. METHODS: A standardized in vitro tube model (n=10) was filled with Onyx 18 and CBCT image acquisition was conducted in a brain imaging phantom. Furthermore, post-interventional CBCT images of 20 patients with AVM (n=13) or dAVF (n=7), each treated with Onyx, were investigated. The MAR software was applied for artifact reduction. Artifacts of the original and the post-processed images were analyzed quantitatively (standard deviation in a region of interest on the layer providing the most artifacts) and qualitatively. For the patient images, the effect of the MAR software on brain parenchyma on artifact-free images was further investigated. RESULTS: Quantitative and qualitative analyses of both datasets demonstrated a lower degree of artifacts in the post-processed images (eg, patient images: 38.30±22.03 density units (no MAR; mean SD±SD) vs 19.83±12.31 density units (with MAR; p<0.001). The MAR software had no influence on the brain parenchyma in artifact-free images. CONCLUSION: The MAR software significantly reduced the artifacts evoked by Onyx in CBCT without affecting the visualization of brain parenchyma on artifact-free images. Applying this software could thus improve the quality of periprocedural CBCT images after embolization with Onyx. BMJ Publishing Group 2022-08 2021-08-25 /pmc/articles/PMC9304113/ /pubmed/34433643 http://dx.doi.org/10.1136/neurintsurg-2021-018018 Text en © Author(s) (or their employer(s)) 2022. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Neuroimaging Schmitt, Niclas Weyland, Charlotte S Wucherpfennig, Lena Sommer, Christof M Bendszus, Martin Möhlenbruch, Markus A Vollherbst, Dominik F The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study |
title | The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study |
title_full | The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study |
title_fullStr | The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study |
title_full_unstemmed | The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study |
title_short | The impact of software-based metal artifact reduction on the liquid embolic agent Onyx in cone-beam CT: a systematic in vitro and in vivo study |
title_sort | impact of software-based metal artifact reduction on the liquid embolic agent onyx in cone-beam ct: a systematic in vitro and in vivo study |
topic | Neuroimaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9304113/ https://www.ncbi.nlm.nih.gov/pubmed/34433643 http://dx.doi.org/10.1136/neurintsurg-2021-018018 |
work_keys_str_mv | AT schmittniclas theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT weylandcharlottes theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT wucherpfenniglena theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT sommerchristofm theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT bendszusmartin theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT mohlenbruchmarkusa theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT vollherbstdominikf theimpactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT schmittniclas impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT weylandcharlottes impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT wucherpfenniglena impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT sommerchristofm impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT bendszusmartin impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT mohlenbruchmarkusa impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy AT vollherbstdominikf impactofsoftwarebasedmetalartifactreductionontheliquidembolicagentonyxinconebeamctasystematicinvitroandinvivostudy |