Cargando…

Serial changes of coronary flow reserve over one year after transcatheter aortic valve implantation in patients with severe aortic stenosis()

BACKGROUND: Impaired coronary flow reserve (CFR) portends a poor prognosis in patients with aortic stenosis. The present study aims to investigate how CFR changes over one year after transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis, and to explore factors relate...

Descripción completa

Detalles Bibliográficos
Autores principales: Wada, Teruaki, Shiono, Yasutsugu, Honda, Kentaro, Higashioka, Daisuke, Taruya, Akira, Takahata, Masahiro, Fujita, Suwako, Ota, Shingo, Satogami, Keisuke, Ozaki, Yuichi, Kashiwagi, Manabu, Kuroi, Akio, Yamano, Takashi, Takemoto, Kazushi, Tanimoto, Takashi, Kitabata, Hironori, Nishimura, Yoshiharu, Tanaka, Atsushi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9304717/
https://www.ncbi.nlm.nih.gov/pubmed/35873862
http://dx.doi.org/10.1016/j.ijcha.2022.101090
_version_ 1784752153156386816
author Wada, Teruaki
Shiono, Yasutsugu
Honda, Kentaro
Higashioka, Daisuke
Taruya, Akira
Takahata, Masahiro
Fujita, Suwako
Ota, Shingo
Satogami, Keisuke
Ozaki, Yuichi
Kashiwagi, Manabu
Kuroi, Akio
Yamano, Takashi
Takemoto, Kazushi
Tanimoto, Takashi
Kitabata, Hironori
Nishimura, Yoshiharu
Tanaka, Atsushi
author_facet Wada, Teruaki
Shiono, Yasutsugu
Honda, Kentaro
Higashioka, Daisuke
Taruya, Akira
Takahata, Masahiro
Fujita, Suwako
Ota, Shingo
Satogami, Keisuke
Ozaki, Yuichi
Kashiwagi, Manabu
Kuroi, Akio
Yamano, Takashi
Takemoto, Kazushi
Tanimoto, Takashi
Kitabata, Hironori
Nishimura, Yoshiharu
Tanaka, Atsushi
author_sort Wada, Teruaki
collection PubMed
description BACKGROUND: Impaired coronary flow reserve (CFR) portends a poor prognosis in patients with aortic stenosis. The present study aims to investigate how CFR changes over one year after transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis, and to explore factors related to the changes. METHODS: Consecutive patients undergoing TAVI were registered. CFR in the left anterior descending artery was measured by transthoracic echocardiography on three occasions pre-TAVI, one-day post-TAVI, and one-year post-TAVI. RESULTS: A total of 59 patients were enrolled, 46 of whom completed one-year follow-up. CFR was impaired in 35 (59.3%) patients pre-TAVI, but the impairment was only seen in 2 patients (4%) one-year post-TAVI. CFR value improved from 1.75 (1.50–2.10) cm/s pre-TAVI, to 2.00 (1.70–2.30) one-day post-TAVI, and further to 2.60 (2.30–3.10) one-year post-TAVI (P < 0.001). The median difference in CFR between pre-TAVI and one-year post-TAVI was 0.90 (0.53–1.20). Patients with significant improvement of CFR (more than the median value of 0.9) had larger aortic valve area (1.55 [1.38–1.92] vs. 1.36 cm(2) [1.26–1.69], P = 0.042) and greater improvement in left ventricular ejection fraction (3.10 [−1.67–4.24] vs. −1.46 [−3.42–1.48] percentage points, P = 0.019) than those without. CONCLUSIONS: CFR is impaired in a considerable proportion of patients with severe aortic stenosis, but improvement is seen immediately after TAVI, and one year later. Patients with significant improvement of CFR had larger aortic valve area and greater increase in left ventricular ejection fraction after TAVI.
format Online
Article
Text
id pubmed-9304717
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-93047172022-07-23 Serial changes of coronary flow reserve over one year after transcatheter aortic valve implantation in patients with severe aortic stenosis() Wada, Teruaki Shiono, Yasutsugu Honda, Kentaro Higashioka, Daisuke Taruya, Akira Takahata, Masahiro Fujita, Suwako Ota, Shingo Satogami, Keisuke Ozaki, Yuichi Kashiwagi, Manabu Kuroi, Akio Yamano, Takashi Takemoto, Kazushi Tanimoto, Takashi Kitabata, Hironori Nishimura, Yoshiharu Tanaka, Atsushi Int J Cardiol Heart Vasc Original Paper BACKGROUND: Impaired coronary flow reserve (CFR) portends a poor prognosis in patients with aortic stenosis. The present study aims to investigate how CFR changes over one year after transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis, and to explore factors related to the changes. METHODS: Consecutive patients undergoing TAVI were registered. CFR in the left anterior descending artery was measured by transthoracic echocardiography on three occasions pre-TAVI, one-day post-TAVI, and one-year post-TAVI. RESULTS: A total of 59 patients were enrolled, 46 of whom completed one-year follow-up. CFR was impaired in 35 (59.3%) patients pre-TAVI, but the impairment was only seen in 2 patients (4%) one-year post-TAVI. CFR value improved from 1.75 (1.50–2.10) cm/s pre-TAVI, to 2.00 (1.70–2.30) one-day post-TAVI, and further to 2.60 (2.30–3.10) one-year post-TAVI (P < 0.001). The median difference in CFR between pre-TAVI and one-year post-TAVI was 0.90 (0.53–1.20). Patients with significant improvement of CFR (more than the median value of 0.9) had larger aortic valve area (1.55 [1.38–1.92] vs. 1.36 cm(2) [1.26–1.69], P = 0.042) and greater improvement in left ventricular ejection fraction (3.10 [−1.67–4.24] vs. −1.46 [−3.42–1.48] percentage points, P = 0.019) than those without. CONCLUSIONS: CFR is impaired in a considerable proportion of patients with severe aortic stenosis, but improvement is seen immediately after TAVI, and one year later. Patients with significant improvement of CFR had larger aortic valve area and greater increase in left ventricular ejection fraction after TAVI. Elsevier 2022-07-18 /pmc/articles/PMC9304717/ /pubmed/35873862 http://dx.doi.org/10.1016/j.ijcha.2022.101090 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Paper
Wada, Teruaki
Shiono, Yasutsugu
Honda, Kentaro
Higashioka, Daisuke
Taruya, Akira
Takahata, Masahiro
Fujita, Suwako
Ota, Shingo
Satogami, Keisuke
Ozaki, Yuichi
Kashiwagi, Manabu
Kuroi, Akio
Yamano, Takashi
Takemoto, Kazushi
Tanimoto, Takashi
Kitabata, Hironori
Nishimura, Yoshiharu
Tanaka, Atsushi
Serial changes of coronary flow reserve over one year after transcatheter aortic valve implantation in patients with severe aortic stenosis()
title Serial changes of coronary flow reserve over one year after transcatheter aortic valve implantation in patients with severe aortic stenosis()
title_full Serial changes of coronary flow reserve over one year after transcatheter aortic valve implantation in patients with severe aortic stenosis()
title_fullStr Serial changes of coronary flow reserve over one year after transcatheter aortic valve implantation in patients with severe aortic stenosis()
title_full_unstemmed Serial changes of coronary flow reserve over one year after transcatheter aortic valve implantation in patients with severe aortic stenosis()
title_short Serial changes of coronary flow reserve over one year after transcatheter aortic valve implantation in patients with severe aortic stenosis()
title_sort serial changes of coronary flow reserve over one year after transcatheter aortic valve implantation in patients with severe aortic stenosis()
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9304717/
https://www.ncbi.nlm.nih.gov/pubmed/35873862
http://dx.doi.org/10.1016/j.ijcha.2022.101090
work_keys_str_mv AT wadateruaki serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT shionoyasutsugu serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT hondakentaro serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT higashiokadaisuke serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT taruyaakira serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT takahatamasahiro serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT fujitasuwako serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT otashingo serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT satogamikeisuke serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT ozakiyuichi serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT kashiwagimanabu serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT kuroiakio serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT yamanotakashi serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT takemotokazushi serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT tanimototakashi serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT kitabatahironori serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT nishimurayoshiharu serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis
AT tanakaatsushi serialchangesofcoronaryflowreserveoveroneyearaftertranscatheteraorticvalveimplantationinpatientswithsevereaorticstenosis