Cargando…

Cemented versus screw‐retained zirconia‐based single‐implant restorations: 5‐year results of a randomized controlled clinical trial

OBJECTIVES: To compare cemented and screw‐retained one‐piece zirconia‐based restorations in terms of clinical, radiographic, and technical outcomes 5 years after insertion. MATERIALS AND METHODS: Thirty‐four patients with single‐tooth implants were randomly restored with either a cemented lithium di...

Descripción completa

Detalles Bibliográficos
Autores principales: Lamperti, Sofia T., Wolleb, Karin, Hämmerle, Christoph H.F., Jung, Ronald E., Hüsler, Jürg, Thoma, Daniel S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9305781/
https://www.ncbi.nlm.nih.gov/pubmed/35051314
http://dx.doi.org/10.1111/clr.13895
Descripción
Sumario:OBJECTIVES: To compare cemented and screw‐retained one‐piece zirconia‐based restorations in terms of clinical, radiographic, and technical outcomes 5 years after insertion. MATERIALS AND METHODS: Thirty‐four patients with single‐tooth implants were randomly restored with either a cemented lithium disilicate crown on a one‐piece customized zirconia abutment (CEM, 17 patients) or a screw‐retained crown based on a directly veneered one‐piece customized zirconia abutment (SCREW, 16 patients). All patients were recalled for a baseline examination (7–10 days after crown insertion) and then annually up to 5 years. The following outcomes were assessed: marginal bone level (changes), technical, and clinical (bleeding on probing, plaque control record, probing depth, and keratinized tissue) parameters. The Mann–Whitney U‐test was used to assess differences between the two groups. RESULTS: At 5 years, 26 patients (13 in each group) were re‐examined. The survival rates on the implant and restorative levels were 100% and 82.4% (equally for both groups), respectively. At 5 years, the median marginal bone level was located at −0.15 mm (IQR: −0.89 mm; 0.27 mm) (CEM) and −0.26 mm (IQR: −0.38 mm; 0.01 mm) (SCREW) below the implant shoulder (intergroup p = .9598). The median changes between baseline and the 5‐year follow‐up amounted to −0.23 mm (CEM; intragroup p = .0002) and −0.15 mm (SCREW; intragroup p = .1465) (intergroup p = .1690). The overall technical complication rate at 5 years was 15.4% (CEM) and 15.4% (SCREW) (intergroup p = 1.00). Clinical parameters remained stable over time (baseline to 5 years). CONCLUSIONS: At 5 years, screw‐retained and cemented restorations rendered largely the same clinical, technical, and radiographic outcomes. Technical complications were frequent in both groups.