Microfocused ultrasound with visualization: Consensus on safety and review of energy‐based devices
BACKGROUND: Microfocused ultrasound with visualization (MFU‐V; Ultherapy(®), Merz North America) is US Food and Drug Administration‐cleared as a non‐invasive procedure that lifts the soft tissue of the neck, submentum and brow, and improves lines and wrinkles on the upper chest. Several other energy...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9305832/ https://www.ncbi.nlm.nih.gov/pubmed/34951735 http://dx.doi.org/10.1111/jocd.14666 |
_version_ | 1784752414140661760 |
---|---|
author | Pavicic, Tatjana Ballard, John R. Bykovskaya, Tatiana Corduff, Niamh Hirano, Cyro Park, Je‐Young Saromytskaya, Alena Sevi, Julia Vasconcelos, Suyan |
author_facet | Pavicic, Tatjana Ballard, John R. Bykovskaya, Tatiana Corduff, Niamh Hirano, Cyro Park, Je‐Young Saromytskaya, Alena Sevi, Julia Vasconcelos, Suyan |
author_sort | Pavicic, Tatjana |
collection | PubMed |
description | BACKGROUND: Microfocused ultrasound with visualization (MFU‐V; Ultherapy(®), Merz North America) is US Food and Drug Administration‐cleared as a non‐invasive procedure that lifts the soft tissue of the neck, submentum and brow, and improves lines and wrinkles on the upper chest. Several other energy‐based devices are in use in countries outside the USA where they are marketed for indications similar to those of MFU‐V, although published studies supporting these indications are limited and none of the other devices provides visualization or verification they reach the superficial musculoaponeurotic system. METHODS: Due to the evolving landscape of ultrasound technology as more devices enter the market, seven global thought leaders who are qualified experts on the use of various high‐intensity focused ultrasound (HIFU)/MFU‐V technologies convened to review data from an independent evaluation of the software, thermal characteristics, transducer acoustics and ultrasound therapy of MFU‐V and three other ultrasound‐based devices. RESULTS: The independent testing demonstrated the devices have key differences in several parameters that play a role in safety and effectiveness. Specifically, MFU‐V has visualization capability but the other devices lack that feature. Other differences include the retention of patient history, consistent size and uniformity of thermal coagulation points (TCPs), precise localization of energy concentration at the focal point, and reliable thermal regulation during use. The expert panel established a consensus on the types of preventable complications associated with ultrasound‐based energy devices and techniques for preventing and treating complications. CONCLUSIONS: The independent test results of MFU‐V/HIFU devices and the consensus panel conclusions provide strong support that real‐time visualization and the capability to detect coupling, features found only in MFU‐V, help prevent complications and enhance the safety and effectiveness of energy‐based devices. The independent evaluation also revealed that MFU‐V has several additional features that play key roles in safety and clinical effectiveness, including uniformity of TCPs, tight thermal regulation, large focal gain, and short beam length, that were not found collectively in any of the HIFU devices. |
format | Online Article Text |
id | pubmed-9305832 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93058322022-07-28 Microfocused ultrasound with visualization: Consensus on safety and review of energy‐based devices Pavicic, Tatjana Ballard, John R. Bykovskaya, Tatiana Corduff, Niamh Hirano, Cyro Park, Je‐Young Saromytskaya, Alena Sevi, Julia Vasconcelos, Suyan J Cosmet Dermatol Energy Based Devices Articles BACKGROUND: Microfocused ultrasound with visualization (MFU‐V; Ultherapy(®), Merz North America) is US Food and Drug Administration‐cleared as a non‐invasive procedure that lifts the soft tissue of the neck, submentum and brow, and improves lines and wrinkles on the upper chest. Several other energy‐based devices are in use in countries outside the USA where they are marketed for indications similar to those of MFU‐V, although published studies supporting these indications are limited and none of the other devices provides visualization or verification they reach the superficial musculoaponeurotic system. METHODS: Due to the evolving landscape of ultrasound technology as more devices enter the market, seven global thought leaders who are qualified experts on the use of various high‐intensity focused ultrasound (HIFU)/MFU‐V technologies convened to review data from an independent evaluation of the software, thermal characteristics, transducer acoustics and ultrasound therapy of MFU‐V and three other ultrasound‐based devices. RESULTS: The independent testing demonstrated the devices have key differences in several parameters that play a role in safety and effectiveness. Specifically, MFU‐V has visualization capability but the other devices lack that feature. Other differences include the retention of patient history, consistent size and uniformity of thermal coagulation points (TCPs), precise localization of energy concentration at the focal point, and reliable thermal regulation during use. The expert panel established a consensus on the types of preventable complications associated with ultrasound‐based energy devices and techniques for preventing and treating complications. CONCLUSIONS: The independent test results of MFU‐V/HIFU devices and the consensus panel conclusions provide strong support that real‐time visualization and the capability to detect coupling, features found only in MFU‐V, help prevent complications and enhance the safety and effectiveness of energy‐based devices. The independent evaluation also revealed that MFU‐V has several additional features that play key roles in safety and clinical effectiveness, including uniformity of TCPs, tight thermal regulation, large focal gain, and short beam length, that were not found collectively in any of the HIFU devices. John Wiley and Sons Inc. 2021-12-24 2022-02 /pmc/articles/PMC9305832/ /pubmed/34951735 http://dx.doi.org/10.1111/jocd.14666 Text en © 2021 The Authors. Journal of Cosmetic Dermatology published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Energy Based Devices Articles Pavicic, Tatjana Ballard, John R. Bykovskaya, Tatiana Corduff, Niamh Hirano, Cyro Park, Je‐Young Saromytskaya, Alena Sevi, Julia Vasconcelos, Suyan Microfocused ultrasound with visualization: Consensus on safety and review of energy‐based devices |
title | Microfocused ultrasound with visualization: Consensus on safety and review of energy‐based devices |
title_full | Microfocused ultrasound with visualization: Consensus on safety and review of energy‐based devices |
title_fullStr | Microfocused ultrasound with visualization: Consensus on safety and review of energy‐based devices |
title_full_unstemmed | Microfocused ultrasound with visualization: Consensus on safety and review of energy‐based devices |
title_short | Microfocused ultrasound with visualization: Consensus on safety and review of energy‐based devices |
title_sort | microfocused ultrasound with visualization: consensus on safety and review of energy‐based devices |
topic | Energy Based Devices Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9305832/ https://www.ncbi.nlm.nih.gov/pubmed/34951735 http://dx.doi.org/10.1111/jocd.14666 |
work_keys_str_mv | AT pavicictatjana microfocusedultrasoundwithvisualizationconsensusonsafetyandreviewofenergybaseddevices AT ballardjohnr microfocusedultrasoundwithvisualizationconsensusonsafetyandreviewofenergybaseddevices AT bykovskayatatiana microfocusedultrasoundwithvisualizationconsensusonsafetyandreviewofenergybaseddevices AT corduffniamh microfocusedultrasoundwithvisualizationconsensusonsafetyandreviewofenergybaseddevices AT hiranocyro microfocusedultrasoundwithvisualizationconsensusonsafetyandreviewofenergybaseddevices AT parkjeyoung microfocusedultrasoundwithvisualizationconsensusonsafetyandreviewofenergybaseddevices AT saromytskayaalena microfocusedultrasoundwithvisualizationconsensusonsafetyandreviewofenergybaseddevices AT sevijulia microfocusedultrasoundwithvisualizationconsensusonsafetyandreviewofenergybaseddevices AT vasconcelossuyan microfocusedultrasoundwithvisualizationconsensusonsafetyandreviewofenergybaseddevices |