Cargando…
Anatomical accuracy of the KODEX‐EPD novel 3D mapping system of the left atrium during pulmonary vein isolation: A correlation with computer tomography imaging
BACKGROUND: A novel 3D mapping system (KODEX‐EPD, EPD Solutions) enables catheter localization and real‐time 3D cardiac mapping. OBJECTIVE: To evaluate left atrium (LA) anatomical mapping accuracy created by the KODEX‐EPD system during pulmonary vein isolation (PVI) compared with gold standard compu...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9306535/ https://www.ncbi.nlm.nih.gov/pubmed/35118762 http://dx.doi.org/10.1111/jce.15391 |
_version_ | 1784752560167452672 |
---|---|
author | Tovia Brodie, Oholi Rav‐Acha, Moshe Wolak, Arik Ilan, Michael Orenstein, David J. Abuhatzera, Shalom Glikson, Michael Michowitz, Yoav |
author_facet | Tovia Brodie, Oholi Rav‐Acha, Moshe Wolak, Arik Ilan, Michael Orenstein, David J. Abuhatzera, Shalom Glikson, Michael Michowitz, Yoav |
author_sort | Tovia Brodie, Oholi |
collection | PubMed |
description | BACKGROUND: A novel 3D mapping system (KODEX‐EPD, EPD Solutions) enables catheter localization and real‐time 3D cardiac mapping. OBJECTIVE: To evaluate left atrium (LA) anatomical mapping accuracy created by the KODEX‐EPD system during pulmonary vein isolation (PVI) compared with gold standard computed tomography (CT) images acquired from the same patients before the procedure. METHODS: In 15 consecutive patients who underwent PVI, 3D mapping of the LA was created on the KODEX‐EPD system using the Achieve catheter. Pulmonary vein (PV), posterior wall, and appendage anatomy and diameters, were compared to the CT 3D reconstruction measured on the CARTO 3 system. Measurements were done independently by two physicians in each method. Linear correlation and agreement between CT and EPD measurements were assessed by Spearman correlation and Bland‐Altman plot. RESULTS: Mean LA mapping time was 7.7 ± 3.6 min. Very high interobserver correlation was found for both EPD and CT measurements (Spearman r = .9). High correlation (r = .75) was found between CT and EPD measurements. Bland‐Altman plot method revealed that measurements assessed by EPD were slightly higher than those assessed by CT. Mean difference was 3.5 mm, p < .01. In 2 (13.5%) patients each, disagreement regarding the presence of a left common PV and a right middle accessory vein anatomy was seen. CONCLUSION: The new KODEX‐EPD mapping system allows quick and accurate mapping of the LA with high correlation to CT imaging. Some differences in left common and accessory right middle vein anatomy were seen. |
format | Online Article Text |
id | pubmed-9306535 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93065352022-07-28 Anatomical accuracy of the KODEX‐EPD novel 3D mapping system of the left atrium during pulmonary vein isolation: A correlation with computer tomography imaging Tovia Brodie, Oholi Rav‐Acha, Moshe Wolak, Arik Ilan, Michael Orenstein, David J. Abuhatzera, Shalom Glikson, Michael Michowitz, Yoav J Cardiovasc Electrophysiol Original Articles BACKGROUND: A novel 3D mapping system (KODEX‐EPD, EPD Solutions) enables catheter localization and real‐time 3D cardiac mapping. OBJECTIVE: To evaluate left atrium (LA) anatomical mapping accuracy created by the KODEX‐EPD system during pulmonary vein isolation (PVI) compared with gold standard computed tomography (CT) images acquired from the same patients before the procedure. METHODS: In 15 consecutive patients who underwent PVI, 3D mapping of the LA was created on the KODEX‐EPD system using the Achieve catheter. Pulmonary vein (PV), posterior wall, and appendage anatomy and diameters, were compared to the CT 3D reconstruction measured on the CARTO 3 system. Measurements were done independently by two physicians in each method. Linear correlation and agreement between CT and EPD measurements were assessed by Spearman correlation and Bland‐Altman plot. RESULTS: Mean LA mapping time was 7.7 ± 3.6 min. Very high interobserver correlation was found for both EPD and CT measurements (Spearman r = .9). High correlation (r = .75) was found between CT and EPD measurements. Bland‐Altman plot method revealed that measurements assessed by EPD were slightly higher than those assessed by CT. Mean difference was 3.5 mm, p < .01. In 2 (13.5%) patients each, disagreement regarding the presence of a left common PV and a right middle accessory vein anatomy was seen. CONCLUSION: The new KODEX‐EPD mapping system allows quick and accurate mapping of the LA with high correlation to CT imaging. Some differences in left common and accessory right middle vein anatomy were seen. John Wiley and Sons Inc. 2022-02-22 2022-04 /pmc/articles/PMC9306535/ /pubmed/35118762 http://dx.doi.org/10.1111/jce.15391 Text en © 2022 The Authors. Journal of Cardiovascular Electrophysiology published by Wiley Periodicals LLC https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Articles Tovia Brodie, Oholi Rav‐Acha, Moshe Wolak, Arik Ilan, Michael Orenstein, David J. Abuhatzera, Shalom Glikson, Michael Michowitz, Yoav Anatomical accuracy of the KODEX‐EPD novel 3D mapping system of the left atrium during pulmonary vein isolation: A correlation with computer tomography imaging |
title | Anatomical accuracy of the KODEX‐EPD novel 3D mapping system of the left atrium during pulmonary vein isolation: A correlation with computer tomography imaging |
title_full | Anatomical accuracy of the KODEX‐EPD novel 3D mapping system of the left atrium during pulmonary vein isolation: A correlation with computer tomography imaging |
title_fullStr | Anatomical accuracy of the KODEX‐EPD novel 3D mapping system of the left atrium during pulmonary vein isolation: A correlation with computer tomography imaging |
title_full_unstemmed | Anatomical accuracy of the KODEX‐EPD novel 3D mapping system of the left atrium during pulmonary vein isolation: A correlation with computer tomography imaging |
title_short | Anatomical accuracy of the KODEX‐EPD novel 3D mapping system of the left atrium during pulmonary vein isolation: A correlation with computer tomography imaging |
title_sort | anatomical accuracy of the kodex‐epd novel 3d mapping system of the left atrium during pulmonary vein isolation: a correlation with computer tomography imaging |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9306535/ https://www.ncbi.nlm.nih.gov/pubmed/35118762 http://dx.doi.org/10.1111/jce.15391 |
work_keys_str_mv | AT toviabrodieoholi anatomicalaccuracyofthekodexepdnovel3dmappingsystemoftheleftatriumduringpulmonaryveinisolationacorrelationwithcomputertomographyimaging AT ravachamoshe anatomicalaccuracyofthekodexepdnovel3dmappingsystemoftheleftatriumduringpulmonaryveinisolationacorrelationwithcomputertomographyimaging AT wolakarik anatomicalaccuracyofthekodexepdnovel3dmappingsystemoftheleftatriumduringpulmonaryveinisolationacorrelationwithcomputertomographyimaging AT ilanmichael anatomicalaccuracyofthekodexepdnovel3dmappingsystemoftheleftatriumduringpulmonaryveinisolationacorrelationwithcomputertomographyimaging AT orensteindavidj anatomicalaccuracyofthekodexepdnovel3dmappingsystemoftheleftatriumduringpulmonaryveinisolationacorrelationwithcomputertomographyimaging AT abuhatzerashalom anatomicalaccuracyofthekodexepdnovel3dmappingsystemoftheleftatriumduringpulmonaryveinisolationacorrelationwithcomputertomographyimaging AT gliksonmichael anatomicalaccuracyofthekodexepdnovel3dmappingsystemoftheleftatriumduringpulmonaryveinisolationacorrelationwithcomputertomographyimaging AT michowitzyoav anatomicalaccuracyofthekodexepdnovel3dmappingsystemoftheleftatriumduringpulmonaryveinisolationacorrelationwithcomputertomographyimaging |