An ultra-rapid drug screening method for acetaminophen in blood serum based on probe electrospray ionization-tandem mass spectrometry

Poisoning incidents caused by drugs, accidental ingestion of poisons, attempted suicide, homicide, and exposure to toxic compounds occur frequently every year across the globe. This raises the need to rapidly identify toxic agents in poisoned patients in a clinical emergency setting. In addition, de...

Descripción completa

Detalles Bibliográficos
Autores principales: Usui, Kiyotaka, Kobayashi, Haruka, Fujita, Yuji, Kubota, Eito, Hanazawa, Tomoki, Yoshizawa, Tomohiro, Kamijo, Yoshito, Funayama, Masato
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taiwan Food and Drug Administration 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9307038/
https://www.ncbi.nlm.nih.gov/pubmed/31324294
http://dx.doi.org/10.1016/j.jfda.2019.02.001
_version_ 1784752679949434880
author Usui, Kiyotaka
Kobayashi, Haruka
Fujita, Yuji
Kubota, Eito
Hanazawa, Tomoki
Yoshizawa, Tomohiro
Kamijo, Yoshito
Funayama, Masato
author_facet Usui, Kiyotaka
Kobayashi, Haruka
Fujita, Yuji
Kubota, Eito
Hanazawa, Tomoki
Yoshizawa, Tomohiro
Kamijo, Yoshito
Funayama, Masato
author_sort Usui, Kiyotaka
collection PubMed
description Poisoning incidents caused by drugs, accidental ingestion of poisons, attempted suicide, homicide, and exposure to toxic compounds occur frequently every year across the globe. This raises the need to rapidly identify toxic agents in poisoned patients in a clinical emergency setting. In addition, determining drug/poison concentration is undoubtedly necessary to arrive at a toxicological treatment plan. The purpose of this study was to develop an ultra-rapid drug screening method for the clinical treatment of poisoning. Probe electrospray ionization (PESI), one of the ambient ionization techniques, is able to detect compounds from various biological materials almost directly. We applied the PESI technique to the rapid detection of acetaminophen (APAP). Blood serum samples were diluted 100-fold with 10 mM ammonium formate/ethanol (1:1 v/v) solution including deuterium-labeled internal standards (IS; APAP-d4). Only 10 μL of the diluted sample was used for measurement. The tandem mass spectrometer (MS/MS) equipped with a PESI was used in selected reaction monitoring mode for the quantitation of APAP; the measurement time was only 18 s. Transitions were set at 152 > 110 for quantitation, 152 > 65 for qualifier, and 156 > 114 for IS (APAP-d4). All measurements were conducted in positive mode. The calibration curve (1/x(2)) was linear over the range of 1.56–200 μg/mL (r(2) = 0.998), and the limit of detection and quantitation were 0.37 μg/mL and 1.56 μg/mL, respectively. The accuracy (bias) and precision (RSD%) of the method were within an acceptable range (−0.15–2.8% and 2.3–6.1%, respectively) and matrix effect at 3 concentrations (95.1–104%) indicated that PESI-MS/MS is only slightly affected by matrices. In real forensic cases, quantitative values of APAP determined by the PESI-MS/MS were almost identical to those determined by the liquid chromatography-MS/MS method. Since PESI-MS/MS is a simple, reliable, and rapid determination method for toxic agents with virtually no need for blood serum pretreatment, it would be highly suitable for poisoning cases in clinical emergency settings. In the future, a method for simultaneous rapid determination of multiple toxic agents will be developed.
format Online
Article
Text
id pubmed-9307038
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Taiwan Food and Drug Administration
record_format MEDLINE/PubMed
spelling pubmed-93070382022-08-09 An ultra-rapid drug screening method for acetaminophen in blood serum based on probe electrospray ionization-tandem mass spectrometry Usui, Kiyotaka Kobayashi, Haruka Fujita, Yuji Kubota, Eito Hanazawa, Tomoki Yoshizawa, Tomohiro Kamijo, Yoshito Funayama, Masato J Food Drug Anal Original Article Poisoning incidents caused by drugs, accidental ingestion of poisons, attempted suicide, homicide, and exposure to toxic compounds occur frequently every year across the globe. This raises the need to rapidly identify toxic agents in poisoned patients in a clinical emergency setting. In addition, determining drug/poison concentration is undoubtedly necessary to arrive at a toxicological treatment plan. The purpose of this study was to develop an ultra-rapid drug screening method for the clinical treatment of poisoning. Probe electrospray ionization (PESI), one of the ambient ionization techniques, is able to detect compounds from various biological materials almost directly. We applied the PESI technique to the rapid detection of acetaminophen (APAP). Blood serum samples were diluted 100-fold with 10 mM ammonium formate/ethanol (1:1 v/v) solution including deuterium-labeled internal standards (IS; APAP-d4). Only 10 μL of the diluted sample was used for measurement. The tandem mass spectrometer (MS/MS) equipped with a PESI was used in selected reaction monitoring mode for the quantitation of APAP; the measurement time was only 18 s. Transitions were set at 152 > 110 for quantitation, 152 > 65 for qualifier, and 156 > 114 for IS (APAP-d4). All measurements were conducted in positive mode. The calibration curve (1/x(2)) was linear over the range of 1.56–200 μg/mL (r(2) = 0.998), and the limit of detection and quantitation were 0.37 μg/mL and 1.56 μg/mL, respectively. The accuracy (bias) and precision (RSD%) of the method were within an acceptable range (−0.15–2.8% and 2.3–6.1%, respectively) and matrix effect at 3 concentrations (95.1–104%) indicated that PESI-MS/MS is only slightly affected by matrices. In real forensic cases, quantitative values of APAP determined by the PESI-MS/MS were almost identical to those determined by the liquid chromatography-MS/MS method. Since PESI-MS/MS is a simple, reliable, and rapid determination method for toxic agents with virtually no need for blood serum pretreatment, it would be highly suitable for poisoning cases in clinical emergency settings. In the future, a method for simultaneous rapid determination of multiple toxic agents will be developed. Taiwan Food and Drug Administration 2019-02-22 /pmc/articles/PMC9307038/ /pubmed/31324294 http://dx.doi.org/10.1016/j.jfda.2019.02.001 Text en © 2019 Taiwan Food and Drug Administration https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) ).
spellingShingle Original Article
Usui, Kiyotaka
Kobayashi, Haruka
Fujita, Yuji
Kubota, Eito
Hanazawa, Tomoki
Yoshizawa, Tomohiro
Kamijo, Yoshito
Funayama, Masato
An ultra-rapid drug screening method for acetaminophen in blood serum based on probe electrospray ionization-tandem mass spectrometry
title An ultra-rapid drug screening method for acetaminophen in blood serum based on probe electrospray ionization-tandem mass spectrometry
title_full An ultra-rapid drug screening method for acetaminophen in blood serum based on probe electrospray ionization-tandem mass spectrometry
title_fullStr An ultra-rapid drug screening method for acetaminophen in blood serum based on probe electrospray ionization-tandem mass spectrometry
title_full_unstemmed An ultra-rapid drug screening method for acetaminophen in blood serum based on probe electrospray ionization-tandem mass spectrometry
title_short An ultra-rapid drug screening method for acetaminophen in blood serum based on probe electrospray ionization-tandem mass spectrometry
title_sort ultra-rapid drug screening method for acetaminophen in blood serum based on probe electrospray ionization-tandem mass spectrometry
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9307038/
https://www.ncbi.nlm.nih.gov/pubmed/31324294
http://dx.doi.org/10.1016/j.jfda.2019.02.001
work_keys_str_mv AT usuikiyotaka anultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT kobayashiharuka anultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT fujitayuji anultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT kubotaeito anultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT hanazawatomoki anultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT yoshizawatomohiro anultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT kamijoyoshito anultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT funayamamasato anultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT usuikiyotaka ultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT kobayashiharuka ultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT fujitayuji ultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT kubotaeito ultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT hanazawatomoki ultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT yoshizawatomohiro ultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT kamijoyoshito ultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry
AT funayamamasato ultrarapiddrugscreeningmethodforacetaminopheninbloodserumbasedonprobeelectrosprayionizationtandemmassspectrometry