Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA

OBJECTIVE: To evaluate the feasibility of reducing the injection velocity and volume of contrast agent according to BMI, and the effect of body weight (BW), body surface area(BSA), body mass index(BMI),and blood volume (BV) on aortic contrast enhancement when the voltage of third-generation dual-sou...

Descripción completa

Detalles Bibliográficos
Autores principales: Ge, Shang, Zhu, Jian-Yao, Liu, Han, Chen, Yuan, Zhu, Zhao-Huan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9308544/
https://www.ncbi.nlm.nih.gov/pubmed/35924071
http://dx.doi.org/10.1155/2022/7804015
_version_ 1784753004603244544
author Ge, Shang
Zhu, Jian-Yao
Liu, Han
Chen, Yuan
Zhu, Zhao-Huan
author_facet Ge, Shang
Zhu, Jian-Yao
Liu, Han
Chen, Yuan
Zhu, Zhao-Huan
author_sort Ge, Shang
collection PubMed
description OBJECTIVE: To evaluate the feasibility of reducing the injection velocity and volume of contrast agent according to BMI, and the effect of body weight (BW), body surface area(BSA), body mass index(BMI),and blood volume (BV) on aortic contrast enhancement when the voltage of third-generation dual-source CT is selected at 70 KV. METHODS: A total of 280 patients selected at 70 KV were randomly divided into an experimental group and a control group. Each group was divided into 7 subgroups according to BMI ≤20, 20–21, 21-22, 22-23, 23-24, 24-25, and 25–26. The experimental group uses 2.3/2.4/2.5/2.6/2.7/2.8/2.9 ml/s injection speed with 350 mgI/ml contrast agents according to the subgroups; injection time was fixed at 10 s. In the control group, the fixed injection flow rate was 3.5 ml/s, time was 12 s with a total of 42 ml. Subjects in both groups were inspected to adaptive prospective ECG-gating sequence scanning, and subjective and objective image quality of the two groups were compared using Student's t-test. BMI, BSA, and BV were calculated from the patient's body weight and height. We assess the relationship between aortic attenuation and BW, BMI, BV, and BSA using regression analysis or correlation analysis. RESULTS: Significant differences exist in vascular enhancement between the two groups; SNR and CNR of objective image quality in the experimental group were lower than those in the control group (P < 0.05). Both groups had the same subjective image scores (P > 0.05). The number of vessels in the optimal enhancement range counts more in the experimental group than in the control group (χ2 value = 334.25, P < 0.05). In the control group, a weak to medium correlation was seen between vascular enhancement and BMI (r = −0.20), BW (r = −0.42), BSA (r = −0.46), and BV (r = −0.48) (P < 0.05 for all). CONCLUSIONS: Compared to BW, BSA, and BV, a weaker negative correlation exists between vascular enhancement and BMI when ATVS selects 70 KV. However, as a much easier way to operate, the stepped low flow and low-contrast agent injection based on BMI was feasible, and the image quality was more homogenized than that of the control group.
format Online
Article
Text
id pubmed-9308544
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-93085442022-08-02 Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA Ge, Shang Zhu, Jian-Yao Liu, Han Chen, Yuan Zhu, Zhao-Huan Contrast Media Mol Imaging Research Article OBJECTIVE: To evaluate the feasibility of reducing the injection velocity and volume of contrast agent according to BMI, and the effect of body weight (BW), body surface area(BSA), body mass index(BMI),and blood volume (BV) on aortic contrast enhancement when the voltage of third-generation dual-source CT is selected at 70 KV. METHODS: A total of 280 patients selected at 70 KV were randomly divided into an experimental group and a control group. Each group was divided into 7 subgroups according to BMI ≤20, 20–21, 21-22, 22-23, 23-24, 24-25, and 25–26. The experimental group uses 2.3/2.4/2.5/2.6/2.7/2.8/2.9 ml/s injection speed with 350 mgI/ml contrast agents according to the subgroups; injection time was fixed at 10 s. In the control group, the fixed injection flow rate was 3.5 ml/s, time was 12 s with a total of 42 ml. Subjects in both groups were inspected to adaptive prospective ECG-gating sequence scanning, and subjective and objective image quality of the two groups were compared using Student's t-test. BMI, BSA, and BV were calculated from the patient's body weight and height. We assess the relationship between aortic attenuation and BW, BMI, BV, and BSA using regression analysis or correlation analysis. RESULTS: Significant differences exist in vascular enhancement between the two groups; SNR and CNR of objective image quality in the experimental group were lower than those in the control group (P < 0.05). Both groups had the same subjective image scores (P > 0.05). The number of vessels in the optimal enhancement range counts more in the experimental group than in the control group (χ2 value = 334.25, P < 0.05). In the control group, a weak to medium correlation was seen between vascular enhancement and BMI (r = −0.20), BW (r = −0.42), BSA (r = −0.46), and BV (r = −0.48) (P < 0.05 for all). CONCLUSIONS: Compared to BW, BSA, and BV, a weaker negative correlation exists between vascular enhancement and BMI when ATVS selects 70 KV. However, as a much easier way to operate, the stepped low flow and low-contrast agent injection based on BMI was feasible, and the image quality was more homogenized than that of the control group. Hindawi 2022-07-16 /pmc/articles/PMC9308544/ /pubmed/35924071 http://dx.doi.org/10.1155/2022/7804015 Text en Copyright © 2022 Shang Ge et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ge, Shang
Zhu, Jian-Yao
Liu, Han
Chen, Yuan
Zhu, Zhao-Huan
Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA
title Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA
title_full Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA
title_fullStr Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA
title_full_unstemmed Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA
title_short Ladder-Like Low Iodine Delivery Rate Injection Protocols Based on BMI at 70 KV by Automated Tube Voltage Selection in Coronary CTA
title_sort ladder-like low iodine delivery rate injection protocols based on bmi at 70 kv by automated tube voltage selection in coronary cta
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9308544/
https://www.ncbi.nlm.nih.gov/pubmed/35924071
http://dx.doi.org/10.1155/2022/7804015
work_keys_str_mv AT geshang ladderlikelowiodinedeliveryrateinjectionprotocolsbasedonbmiat70kvbyautomatedtubevoltageselectionincoronarycta
AT zhujianyao ladderlikelowiodinedeliveryrateinjectionprotocolsbasedonbmiat70kvbyautomatedtubevoltageselectionincoronarycta
AT liuhan ladderlikelowiodinedeliveryrateinjectionprotocolsbasedonbmiat70kvbyautomatedtubevoltageselectionincoronarycta
AT chenyuan ladderlikelowiodinedeliveryrateinjectionprotocolsbasedonbmiat70kvbyautomatedtubevoltageselectionincoronarycta
AT zhuzhaohuan ladderlikelowiodinedeliveryrateinjectionprotocolsbasedonbmiat70kvbyautomatedtubevoltageselectionincoronarycta