Cargando…

Translation of 3D Anatomy to 2D Radiographic Angle Measurements in the Ankle Joint: Validity and Reliability

BACKGROUND: The objective consisted of 2 elements, primarily to define 2 bone geometry variations of the ankle that may be of prognostic value on ankle instability and secondly to translate these bone variations from a 3D model to a simple 2D radiographic measurement for clinical use. METHODS: The 3...

Descripción completa

Detalles Bibliográficos
Autores principales: Vuurberg, Gwendolyn, Tümer, Nazli, Sierevelt, Inger, Dobbe, Johannes G. G., Hemke, Robert, Wiegerinck, Jan Joost, Maas, Mario, Kerkhoffs, Gino M. M. J., Tuijthof, Gabriëlle J. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9310239/
https://www.ncbi.nlm.nih.gov/pubmed/35898795
http://dx.doi.org/10.1177/24730114221112945
_version_ 1784753346608889856
author Vuurberg, Gwendolyn
Tümer, Nazli
Sierevelt, Inger
Dobbe, Johannes G. G.
Hemke, Robert
Wiegerinck, Jan Joost
Maas, Mario
Kerkhoffs, Gino M. M. J.
Tuijthof, Gabriëlle J. M.
author_facet Vuurberg, Gwendolyn
Tümer, Nazli
Sierevelt, Inger
Dobbe, Johannes G. G.
Hemke, Robert
Wiegerinck, Jan Joost
Maas, Mario
Kerkhoffs, Gino M. M. J.
Tuijthof, Gabriëlle J. M.
author_sort Vuurberg, Gwendolyn
collection PubMed
description BACKGROUND: The objective consisted of 2 elements, primarily to define 2 bone geometry variations of the ankle that may be of prognostic value on ankle instability and secondly to translate these bone variations from a 3D model to a simple 2D radiographic measurement for clinical use. METHODS: The 3D tibial and talar shape differences derived from earlier studies were translated to two 2D radiographic parameters: the medial malleolar height angle (MMHA) and talar convexity angle (TCA) respectively to ensure clinical use. To assess validity, the MMHA and TCA were measured on 3D polygons derived from lower leg computed tomographic (CT) scans and 2D digitally reconstructed radiographs (DRRs) of these polygons. To assess reliability, the MMHA and TCA were measured on standard radiographs by 2 observers calculating the intraclass correlation coefficient (ICC). RESULTS: The 3D angle measurements on the polygons showed substantial to excellent agreement with the 2D measurements on DRR for both the MMHA (ICC 0.84-0.93) and TCA (ICC 0.88-0.96). The interobserver reliability was moderate with an ICC of 0.58 and an ICC of 0.64 for both the MMHA and TCA, respectively. The intraobserver reliability was excellent with an ICC of 0.96 and 0.97 for the MMHA and the TCA, respectively. CONCLUSION: Two newly defined radiographic parameters (MMHA and TCA) are valid and can be assessed with excellent intraobserver reliability on standard radiographs. The interobserver reliability was moderate and indicates training is required to ensure uniformity in measurement technique. The current method may be used to translate more variations in bone shape prior to implementation in clinical practice. LEVEL OF EVIDENCE: Level III, cohort study.
format Online
Article
Text
id pubmed-9310239
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-93102392022-07-26 Translation of 3D Anatomy to 2D Radiographic Angle Measurements in the Ankle Joint: Validity and Reliability Vuurberg, Gwendolyn Tümer, Nazli Sierevelt, Inger Dobbe, Johannes G. G. Hemke, Robert Wiegerinck, Jan Joost Maas, Mario Kerkhoffs, Gino M. M. J. Tuijthof, Gabriëlle J. M. Foot Ankle Orthop Article BACKGROUND: The objective consisted of 2 elements, primarily to define 2 bone geometry variations of the ankle that may be of prognostic value on ankle instability and secondly to translate these bone variations from a 3D model to a simple 2D radiographic measurement for clinical use. METHODS: The 3D tibial and talar shape differences derived from earlier studies were translated to two 2D radiographic parameters: the medial malleolar height angle (MMHA) and talar convexity angle (TCA) respectively to ensure clinical use. To assess validity, the MMHA and TCA were measured on 3D polygons derived from lower leg computed tomographic (CT) scans and 2D digitally reconstructed radiographs (DRRs) of these polygons. To assess reliability, the MMHA and TCA were measured on standard radiographs by 2 observers calculating the intraclass correlation coefficient (ICC). RESULTS: The 3D angle measurements on the polygons showed substantial to excellent agreement with the 2D measurements on DRR for both the MMHA (ICC 0.84-0.93) and TCA (ICC 0.88-0.96). The interobserver reliability was moderate with an ICC of 0.58 and an ICC of 0.64 for both the MMHA and TCA, respectively. The intraobserver reliability was excellent with an ICC of 0.96 and 0.97 for the MMHA and the TCA, respectively. CONCLUSION: Two newly defined radiographic parameters (MMHA and TCA) are valid and can be assessed with excellent intraobserver reliability on standard radiographs. The interobserver reliability was moderate and indicates training is required to ensure uniformity in measurement technique. The current method may be used to translate more variations in bone shape prior to implementation in clinical practice. LEVEL OF EVIDENCE: Level III, cohort study. SAGE Publications 2022-07-21 /pmc/articles/PMC9310239/ /pubmed/35898795 http://dx.doi.org/10.1177/24730114221112945 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/This article is distributed under the terms of the Creative Commons Attribution 4.0 License (https://creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Vuurberg, Gwendolyn
Tümer, Nazli
Sierevelt, Inger
Dobbe, Johannes G. G.
Hemke, Robert
Wiegerinck, Jan Joost
Maas, Mario
Kerkhoffs, Gino M. M. J.
Tuijthof, Gabriëlle J. M.
Translation of 3D Anatomy to 2D Radiographic Angle Measurements in the Ankle Joint: Validity and Reliability
title Translation of 3D Anatomy to 2D Radiographic Angle Measurements in the Ankle Joint: Validity and Reliability
title_full Translation of 3D Anatomy to 2D Radiographic Angle Measurements in the Ankle Joint: Validity and Reliability
title_fullStr Translation of 3D Anatomy to 2D Radiographic Angle Measurements in the Ankle Joint: Validity and Reliability
title_full_unstemmed Translation of 3D Anatomy to 2D Radiographic Angle Measurements in the Ankle Joint: Validity and Reliability
title_short Translation of 3D Anatomy to 2D Radiographic Angle Measurements in the Ankle Joint: Validity and Reliability
title_sort translation of 3d anatomy to 2d radiographic angle measurements in the ankle joint: validity and reliability
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9310239/
https://www.ncbi.nlm.nih.gov/pubmed/35898795
http://dx.doi.org/10.1177/24730114221112945
work_keys_str_mv AT vuurberggwendolyn translationof3danatomyto2dradiographicanglemeasurementsintheanklejointvalidityandreliability
AT tumernazli translationof3danatomyto2dradiographicanglemeasurementsintheanklejointvalidityandreliability
AT siereveltinger translationof3danatomyto2dradiographicanglemeasurementsintheanklejointvalidityandreliability
AT dobbejohannesgg translationof3danatomyto2dradiographicanglemeasurementsintheanklejointvalidityandreliability
AT hemkerobert translationof3danatomyto2dradiographicanglemeasurementsintheanklejointvalidityandreliability
AT wiegerinckjanjoost translationof3danatomyto2dradiographicanglemeasurementsintheanklejointvalidityandreliability
AT maasmario translationof3danatomyto2dradiographicanglemeasurementsintheanklejointvalidityandreliability
AT kerkhoffsginommj translationof3danatomyto2dradiographicanglemeasurementsintheanklejointvalidityandreliability
AT tuijthofgabriellejm translationof3danatomyto2dradiographicanglemeasurementsintheanklejointvalidityandreliability