The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
OBJECTIVE: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. METHODOLOGY: Disk-shaped specimens (Ø:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Faculdade De Odontologia De Bauru - USP
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9311270/ https://www.ncbi.nlm.nih.gov/pubmed/35894388 http://dx.doi.org/10.1590/1678-7757-2022-0161 |
_version_ | 1784753568838844416 |
---|---|
author | POLYCHRONAKIS, Nick DIMITRIADI, Maria POLYZOIS, Gregory ELIADES, George |
author_facet | POLYCHRONAKIS, Nick DIMITRIADI, Maria POLYZOIS, Gregory ELIADES, George |
author_sort | POLYCHRONAKIS, Nick |
collection | PubMed |
description | OBJECTIVE: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. METHODOLOGY: Disk-shaped specimens (Ø:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB), Stellon QC-20 (QC) and Vertex Rapid Simplified (VE) denture materials using five different cooling procedures (n=3/procedure): A) Bench-cooling for 10 min and then under running water for 15 min; B) Cooling in water-bath until room temperature; C) Cooling under running water for 15 min; D) Bench-cooling, and E) Bench-cooling for 30 min and under running water for 15 min. A, B, D, E procedures were proposed by the manufacturers, while the C was selected as the fastest one. Control specimens (n=3/material) were fabricated using a long polymerization cycle and bench-cooling. After deflasking, the specimens were ground, polished and stored in individual containers with 10 ml of distilled water for seven days (37(o)C). The amount of water-eluted MMA was measured per container using isocratic ultra-fast liquid chromatography (UFLC). Data were analyzed using Student’s and Welch’s t-test (α=0.05). RESULTS: MMA values below the lower quantification limit (LoQ=5.9 ppm) were registered in B, C, E (PA); E (PB) and B, D, E (QC) procedures, whereas values below the detection limit (LoD=1.96 ppm) were registered in A, D (PA); A, B, C, D (PB); C, D, E (VE) and in all specimens of the control group. A, B (VE) and A, C (QC) procedures yielded values ranging from 6.4 to 13.2 ppm with insignificant differences in material and procedure factors (p>0.05). CONCLUSIONS: The cooling procedures may affect the monomer elution from denture base materials. The Ε procedure may be considered a universal cooling procedure compared to the ones proposed by the manufacturers, with the lowest residual monomer elution in water. |
format | Online Article Text |
id | pubmed-9311270 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Faculdade De Odontologia De Bauru - USP |
record_format | MEDLINE/PubMed |
spelling | pubmed-93112702022-07-29 The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials POLYCHRONAKIS, Nick DIMITRIADI, Maria POLYZOIS, Gregory ELIADES, George J Appl Oral Sci Original Article OBJECTIVE: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. METHODOLOGY: Disk-shaped specimens (Ø:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB), Stellon QC-20 (QC) and Vertex Rapid Simplified (VE) denture materials using five different cooling procedures (n=3/procedure): A) Bench-cooling for 10 min and then under running water for 15 min; B) Cooling in water-bath until room temperature; C) Cooling under running water for 15 min; D) Bench-cooling, and E) Bench-cooling for 30 min and under running water for 15 min. A, B, D, E procedures were proposed by the manufacturers, while the C was selected as the fastest one. Control specimens (n=3/material) were fabricated using a long polymerization cycle and bench-cooling. After deflasking, the specimens were ground, polished and stored in individual containers with 10 ml of distilled water for seven days (37(o)C). The amount of water-eluted MMA was measured per container using isocratic ultra-fast liquid chromatography (UFLC). Data were analyzed using Student’s and Welch’s t-test (α=0.05). RESULTS: MMA values below the lower quantification limit (LoQ=5.9 ppm) were registered in B, C, E (PA); E (PB) and B, D, E (QC) procedures, whereas values below the detection limit (LoD=1.96 ppm) were registered in A, D (PA); A, B, C, D (PB); C, D, E (VE) and in all specimens of the control group. A, B (VE) and A, C (QC) procedures yielded values ranging from 6.4 to 13.2 ppm with insignificant differences in material and procedure factors (p>0.05). CONCLUSIONS: The cooling procedures may affect the monomer elution from denture base materials. The Ε procedure may be considered a universal cooling procedure compared to the ones proposed by the manufacturers, with the lowest residual monomer elution in water. Faculdade De Odontologia De Bauru - USP 2022-07-22 /pmc/articles/PMC9311270/ /pubmed/35894388 http://dx.doi.org/10.1590/1678-7757-2022-0161 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article POLYCHRONAKIS, Nick DIMITRIADI, Maria POLYZOIS, Gregory ELIADES, George The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials |
title | The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials |
title_full | The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials |
title_fullStr | The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials |
title_full_unstemmed | The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials |
title_short | The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials |
title_sort | effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9311270/ https://www.ncbi.nlm.nih.gov/pubmed/35894388 http://dx.doi.org/10.1590/1678-7757-2022-0161 |
work_keys_str_mv | AT polychronakisnick theeffectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials AT dimitriadimaria theeffectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials AT polyzoisgregory theeffectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials AT eliadesgeorge theeffectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials AT polychronakisnick effectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials AT dimitriadimaria effectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials AT polyzoisgregory effectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials AT eliadesgeorge effectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials |