Cargando…

The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials

OBJECTIVE: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. METHODOLOGY: Disk-shaped specimens (Ø:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB...

Descripción completa

Detalles Bibliográficos
Autores principales: POLYCHRONAKIS, Nick, DIMITRIADI, Maria, POLYZOIS, Gregory, ELIADES, George
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade De Odontologia De Bauru - USP 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9311270/
https://www.ncbi.nlm.nih.gov/pubmed/35894388
http://dx.doi.org/10.1590/1678-7757-2022-0161
_version_ 1784753568838844416
author POLYCHRONAKIS, Nick
DIMITRIADI, Maria
POLYZOIS, Gregory
ELIADES, George
author_facet POLYCHRONAKIS, Nick
DIMITRIADI, Maria
POLYZOIS, Gregory
ELIADES, George
author_sort POLYCHRONAKIS, Nick
collection PubMed
description OBJECTIVE: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. METHODOLOGY: Disk-shaped specimens (Ø:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB), Stellon QC-20 (QC) and Vertex Rapid Simplified (VE) denture materials using five different cooling procedures (n=3/procedure): A) Bench-cooling for 10 min and then under running water for 15 min; B) Cooling in water-bath until room temperature; C) Cooling under running water for 15 min; D) Bench-cooling, and E) Bench-cooling for 30 min and under running water for 15 min. A, B, D, E procedures were proposed by the manufacturers, while the C was selected as the fastest one. Control specimens (n=3/material) were fabricated using a long polymerization cycle and bench-cooling. After deflasking, the specimens were ground, polished and stored in individual containers with 10 ml of distilled water for seven days (37(o)C). The amount of water-eluted MMA was measured per container using isocratic ultra-fast liquid chromatography (UFLC). Data were analyzed using Student’s and Welch’s t-test (α=0.05). RESULTS: MMA values below the lower quantification limit (LoQ=5.9 ppm) were registered in B, C, E (PA); E (PB) and B, D, E (QC) procedures, whereas values below the detection limit (LoD=1.96 ppm) were registered in A, D (PA); A, B, C, D (PB); C, D, E (VE) and in all specimens of the control group. A, B (VE) and A, C (QC) procedures yielded values ranging from 6.4 to 13.2 ppm with insignificant differences in material and procedure factors (p>0.05). CONCLUSIONS: The cooling procedures may affect the monomer elution from denture base materials. The Ε procedure may be considered a universal cooling procedure compared to the ones proposed by the manufacturers, with the lowest residual monomer elution in water.
format Online
Article
Text
id pubmed-9311270
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Faculdade De Odontologia De Bauru - USP
record_format MEDLINE/PubMed
spelling pubmed-93112702022-07-29 The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials POLYCHRONAKIS, Nick DIMITRIADI, Maria POLYZOIS, Gregory ELIADES, George J Appl Oral Sci Original Article OBJECTIVE: To evaluate the amount of methyl methacrylate (MMA) released in water from heat-cured polymethyl methacrylate (PMMA) denture base materials subjected to different cooling procedures. METHODOLOGY: Disk-shaped specimens (Ø:17 mm, h:2 mm) were fabricated from Paladon 65 (PA), ProBase Hot (PB), Stellon QC-20 (QC) and Vertex Rapid Simplified (VE) denture materials using five different cooling procedures (n=3/procedure): A) Bench-cooling for 10 min and then under running water for 15 min; B) Cooling in water-bath until room temperature; C) Cooling under running water for 15 min; D) Bench-cooling, and E) Bench-cooling for 30 min and under running water for 15 min. A, B, D, E procedures were proposed by the manufacturers, while the C was selected as the fastest one. Control specimens (n=3/material) were fabricated using a long polymerization cycle and bench-cooling. After deflasking, the specimens were ground, polished and stored in individual containers with 10 ml of distilled water for seven days (37(o)C). The amount of water-eluted MMA was measured per container using isocratic ultra-fast liquid chromatography (UFLC). Data were analyzed using Student’s and Welch’s t-test (α=0.05). RESULTS: MMA values below the lower quantification limit (LoQ=5.9 ppm) were registered in B, C, E (PA); E (PB) and B, D, E (QC) procedures, whereas values below the detection limit (LoD=1.96 ppm) were registered in A, D (PA); A, B, C, D (PB); C, D, E (VE) and in all specimens of the control group. A, B (VE) and A, C (QC) procedures yielded values ranging from 6.4 to 13.2 ppm with insignificant differences in material and procedure factors (p>0.05). CONCLUSIONS: The cooling procedures may affect the monomer elution from denture base materials. The Ε procedure may be considered a universal cooling procedure compared to the ones proposed by the manufacturers, with the lowest residual monomer elution in water. Faculdade De Odontologia De Bauru - USP 2022-07-22 /pmc/articles/PMC9311270/ /pubmed/35894388 http://dx.doi.org/10.1590/1678-7757-2022-0161 Text en https://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
POLYCHRONAKIS, Nick
DIMITRIADI, Maria
POLYZOIS, Gregory
ELIADES, George
The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
title The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
title_full The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
title_fullStr The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
title_full_unstemmed The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
title_short The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
title_sort effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9311270/
https://www.ncbi.nlm.nih.gov/pubmed/35894388
http://dx.doi.org/10.1590/1678-7757-2022-0161
work_keys_str_mv AT polychronakisnick theeffectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials
AT dimitriadimaria theeffectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials
AT polyzoisgregory theeffectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials
AT eliadesgeorge theeffectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials
AT polychronakisnick effectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials
AT dimitriadimaria effectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials
AT polyzoisgregory effectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials
AT eliadesgeorge effectofcoolingproceduresonmonomerelutionfromheatcuredpolymethylmethacrylatedenturebasematerials