Cargando…

A multi‐laboratory assessment of lupus anticoagulant assays performed on the ACL TOP 50 family for harmonized testing in a large laboratory network

INTRODUCTION: Lupus anticoagulant (LA) testing is commonly performed within hemostasis laboratories, and the ACL TOP 50 family of instruments represent a new “single platform” of hemostasis instrumentation. Our aim was to evaluate these instruments and manufacturer reagents or alternatives for utili...

Descripción completa

Detalles Bibliográficos
Autores principales: Favaloro, Emmanuel J., Mohammed, Soma, Vong, Ronny, Chapman, Kent, Swanepoel, Priscilla, Kershaw, Geoffrey, Cai, Nancy, Just, Sarah, Connelly, Lynne, Brighton, Timothy, Pasalic, Leonardo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9311435/
https://www.ncbi.nlm.nih.gov/pubmed/35234361
http://dx.doi.org/10.1111/ijlh.13818
_version_ 1784753596197240832
author Favaloro, Emmanuel J.
Mohammed, Soma
Vong, Ronny
Chapman, Kent
Swanepoel, Priscilla
Kershaw, Geoffrey
Cai, Nancy
Just, Sarah
Connelly, Lynne
Brighton, Timothy
Pasalic, Leonardo
author_facet Favaloro, Emmanuel J.
Mohammed, Soma
Vong, Ronny
Chapman, Kent
Swanepoel, Priscilla
Kershaw, Geoffrey
Cai, Nancy
Just, Sarah
Connelly, Lynne
Brighton, Timothy
Pasalic, Leonardo
author_sort Favaloro, Emmanuel J.
collection PubMed
description INTRODUCTION: Lupus anticoagulant (LA) testing is commonly performed within hemostasis laboratories, and the ACL TOP 50 family of instruments represent a new “single platform” of hemostasis instrumentation. Our aim was to evaluate these instruments and manufacturer reagents or alternatives for utility in LA testing. METHODS: Comparative evaluations of LA testing using newly installed ACL TOPs 550 and 750 as well as comparative assessments with existing “reference,” predominantly Stago, instrumentation, and reagents. Evaluations comprised both dilute Russell viper venom time (dRVVT) and activated partial thromboplastin time (APTT)‐based assays. Establishment of normal reference ranges (NRR). RESULTS: The HemosIL dRVVT‐based assays showed good comparability with the existing Stago reference method (R > 0.9) and could be considered as verified as fit for purpose. A variety of APTT assays was additionally evaluated for LA utility, and we identified from the assessment good utility of a non‐Werfen solution in Hyphen BioMed Cephen reagents. NRR were established based on ≥120 normal individual plasma samples. CONCLUSION: This evaluation of LA reagents on ACL TOP 50 Family instruments identified overall acceptable performance of both dRVVT (Werfen solution) and APTT (non‐Werfen solution) to enable harmonization of LA testing in our large network.
format Online
Article
Text
id pubmed-9311435
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-93114352022-07-29 A multi‐laboratory assessment of lupus anticoagulant assays performed on the ACL TOP 50 family for harmonized testing in a large laboratory network Favaloro, Emmanuel J. Mohammed, Soma Vong, Ronny Chapman, Kent Swanepoel, Priscilla Kershaw, Geoffrey Cai, Nancy Just, Sarah Connelly, Lynne Brighton, Timothy Pasalic, Leonardo Int J Lab Hematol Original Articles INTRODUCTION: Lupus anticoagulant (LA) testing is commonly performed within hemostasis laboratories, and the ACL TOP 50 family of instruments represent a new “single platform” of hemostasis instrumentation. Our aim was to evaluate these instruments and manufacturer reagents or alternatives for utility in LA testing. METHODS: Comparative evaluations of LA testing using newly installed ACL TOPs 550 and 750 as well as comparative assessments with existing “reference,” predominantly Stago, instrumentation, and reagents. Evaluations comprised both dilute Russell viper venom time (dRVVT) and activated partial thromboplastin time (APTT)‐based assays. Establishment of normal reference ranges (NRR). RESULTS: The HemosIL dRVVT‐based assays showed good comparability with the existing Stago reference method (R > 0.9) and could be considered as verified as fit for purpose. A variety of APTT assays was additionally evaluated for LA utility, and we identified from the assessment good utility of a non‐Werfen solution in Hyphen BioMed Cephen reagents. NRR were established based on ≥120 normal individual plasma samples. CONCLUSION: This evaluation of LA reagents on ACL TOP 50 Family instruments identified overall acceptable performance of both dRVVT (Werfen solution) and APTT (non‐Werfen solution) to enable harmonization of LA testing in our large network. John Wiley and Sons Inc. 2022-03-01 2022-06 /pmc/articles/PMC9311435/ /pubmed/35234361 http://dx.doi.org/10.1111/ijlh.13818 Text en © 2022 The Authors. International Journal of Laboratory Hematology published by John Wiley & Sons Ltd. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
Favaloro, Emmanuel J.
Mohammed, Soma
Vong, Ronny
Chapman, Kent
Swanepoel, Priscilla
Kershaw, Geoffrey
Cai, Nancy
Just, Sarah
Connelly, Lynne
Brighton, Timothy
Pasalic, Leonardo
A multi‐laboratory assessment of lupus anticoagulant assays performed on the ACL TOP 50 family for harmonized testing in a large laboratory network
title A multi‐laboratory assessment of lupus anticoagulant assays performed on the ACL TOP 50 family for harmonized testing in a large laboratory network
title_full A multi‐laboratory assessment of lupus anticoagulant assays performed on the ACL TOP 50 family for harmonized testing in a large laboratory network
title_fullStr A multi‐laboratory assessment of lupus anticoagulant assays performed on the ACL TOP 50 family for harmonized testing in a large laboratory network
title_full_unstemmed A multi‐laboratory assessment of lupus anticoagulant assays performed on the ACL TOP 50 family for harmonized testing in a large laboratory network
title_short A multi‐laboratory assessment of lupus anticoagulant assays performed on the ACL TOP 50 family for harmonized testing in a large laboratory network
title_sort multi‐laboratory assessment of lupus anticoagulant assays performed on the acl top 50 family for harmonized testing in a large laboratory network
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9311435/
https://www.ncbi.nlm.nih.gov/pubmed/35234361
http://dx.doi.org/10.1111/ijlh.13818
work_keys_str_mv AT favaloroemmanuelj amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT mohammedsoma amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT vongronny amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT chapmankent amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT swanepoelpriscilla amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT kershawgeoffrey amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT cainancy amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT justsarah amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT connellylynne amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT brightontimothy amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT pasalicleonardo amultilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT favaloroemmanuelj multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT mohammedsoma multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT vongronny multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT chapmankent multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT swanepoelpriscilla multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT kershawgeoffrey multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT cainancy multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT justsarah multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT connellylynne multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT brightontimothy multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork
AT pasalicleonardo multilaboratoryassessmentoflupusanticoagulantassaysperformedontheacltop50familyforharmonizedtestinginalargelaboratorynetwork