Cargando…

Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe(2+) or Fe(3+) Ions

We constructed a sensor for the determination of Fe(2+) and/or Fe(3+) ions that consists of a polyaniline layer as an ion-to-electron transducer; on top of it, chelating molecules are deposited (which can selectively chelate specific ions) and protected with a non-biofouling poly(2-methyl-2-oxazolin...

Descripción completa

Detalles Bibliográficos
Autores principales: Ismail, Rimeh, Šeděnková, Ivana, Černochová, Zulfiya, Romanenko, Iryna, Pop-Georgievski, Ognen, Hrubý, Martin, Tomšík, Elena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9313018/
https://www.ncbi.nlm.nih.gov/pubmed/35884249
http://dx.doi.org/10.3390/bios12070446
_version_ 1784753976076402688
author Ismail, Rimeh
Šeděnková, Ivana
Černochová, Zulfiya
Romanenko, Iryna
Pop-Georgievski, Ognen
Hrubý, Martin
Tomšík, Elena
author_facet Ismail, Rimeh
Šeděnková, Ivana
Černochová, Zulfiya
Romanenko, Iryna
Pop-Georgievski, Ognen
Hrubý, Martin
Tomšík, Elena
author_sort Ismail, Rimeh
collection PubMed
description We constructed a sensor for the determination of Fe(2+) and/or Fe(3+) ions that consists of a polyaniline layer as an ion-to-electron transducer; on top of it, chelating molecules are deposited (which can selectively chelate specific ions) and protected with a non-biofouling poly(2-methyl-2-oxazoline)s layer. We have shown that our potentiometric sensing layers show a rapid response to the presence of Fe(2+) or Fe(3+) ions, do not experience interference with other ions (such as Cu(2+)), and work in a biological environment in the presence of bovine serum albumin (as a model serum protein). The sensing layers detect iron ions in the concentration range from 5 nM to 50 µM.
format Online
Article
Text
id pubmed-9313018
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93130182022-07-26 Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe(2+) or Fe(3+) Ions Ismail, Rimeh Šeděnková, Ivana Černochová, Zulfiya Romanenko, Iryna Pop-Georgievski, Ognen Hrubý, Martin Tomšík, Elena Biosensors (Basel) Article We constructed a sensor for the determination of Fe(2+) and/or Fe(3+) ions that consists of a polyaniline layer as an ion-to-electron transducer; on top of it, chelating molecules are deposited (which can selectively chelate specific ions) and protected with a non-biofouling poly(2-methyl-2-oxazoline)s layer. We have shown that our potentiometric sensing layers show a rapid response to the presence of Fe(2+) or Fe(3+) ions, do not experience interference with other ions (such as Cu(2+)), and work in a biological environment in the presence of bovine serum albumin (as a model serum protein). The sensing layers detect iron ions in the concentration range from 5 nM to 50 µM. MDPI 2022-06-23 /pmc/articles/PMC9313018/ /pubmed/35884249 http://dx.doi.org/10.3390/bios12070446 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ismail, Rimeh
Šeděnková, Ivana
Černochová, Zulfiya
Romanenko, Iryna
Pop-Georgievski, Ognen
Hrubý, Martin
Tomšík, Elena
Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe(2+) or Fe(3+) Ions
title Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe(2+) or Fe(3+) Ions
title_full Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe(2+) or Fe(3+) Ions
title_fullStr Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe(2+) or Fe(3+) Ions
title_full_unstemmed Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe(2+) or Fe(3+) Ions
title_short Potentiometric Performance of Ion-Selective Electrodes Based on Polyaniline and Chelating Agents: Detection of Fe(2+) or Fe(3+) Ions
title_sort potentiometric performance of ion-selective electrodes based on polyaniline and chelating agents: detection of fe(2+) or fe(3+) ions
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9313018/
https://www.ncbi.nlm.nih.gov/pubmed/35884249
http://dx.doi.org/10.3390/bios12070446
work_keys_str_mv AT ismailrimeh potentiometricperformanceofionselectiveelectrodesbasedonpolyanilineandchelatingagentsdetectionoffe2orfe3ions
AT sedenkovaivana potentiometricperformanceofionselectiveelectrodesbasedonpolyanilineandchelatingagentsdetectionoffe2orfe3ions
AT cernochovazulfiya potentiometricperformanceofionselectiveelectrodesbasedonpolyanilineandchelatingagentsdetectionoffe2orfe3ions
AT romanenkoiryna potentiometricperformanceofionselectiveelectrodesbasedonpolyanilineandchelatingagentsdetectionoffe2orfe3ions
AT popgeorgievskiognen potentiometricperformanceofionselectiveelectrodesbasedonpolyanilineandchelatingagentsdetectionoffe2orfe3ions
AT hrubymartin potentiometricperformanceofionselectiveelectrodesbasedonpolyanilineandchelatingagentsdetectionoffe2orfe3ions
AT tomsikelena potentiometricperformanceofionselectiveelectrodesbasedonpolyanilineandchelatingagentsdetectionoffe2orfe3ions