Can Tiger (TIG) Catheters Be a Solution to the Radial Artery Spasm (RAS) in Coronary Angioplasty? A Case-Based Report of Successful Reperfusion With the Use of 5-French (Fr) TIG Catheter and Literature Review
Conventionally, during a primary percutaneous coronary intervention (PPCI), a diagnostic catheter is used to visualize the contralateral coronary system from the site of the acute occlusion. For that purpose, Judkins Right 4 (JR4) or Judkins Left 3.5 (JL3.5) diagnostic catheters are usually preferre...
Autores principales: | Khan, Zahid, Besis, George, Upadhyaya, Chetan, Neoh, Soon |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9314273/ https://www.ncbi.nlm.nih.gov/pubmed/35911293 http://dx.doi.org/10.7759/cureus.26334 |