Cargando…
Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes
PURPOSE: To evaluate the changes in the angle of the AC and lens vault after IPCL implantation by AS-OCT in myopic patients. METHODS: This was a prospective observational study involving 30 myopic eyes implanted with IPCL. AS-OCT was used to evaluate lens vault and AC angle parameters including ante...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Netherlands
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9314284/ https://www.ncbi.nlm.nih.gov/pubmed/35243558 http://dx.doi.org/10.1007/s10792-022-02244-2 |
_version_ | 1784754284740476928 |
---|---|
author | Mahmoud, Mohamed Salah El-Din Mohamed, Asmaa Anwar Zein, Hosny Ahmed |
author_facet | Mahmoud, Mohamed Salah El-Din Mohamed, Asmaa Anwar Zein, Hosny Ahmed |
author_sort | Mahmoud, Mohamed Salah El-Din |
collection | PubMed |
description | PURPOSE: To evaluate the changes in the angle of the AC and lens vault after IPCL implantation by AS-OCT in myopic patients. METHODS: This was a prospective observational study involving 30 myopic eyes implanted with IPCL. AS-OCT was used to evaluate lens vault and AC angle parameters including anterior chamber angle, angle opening distance and trabecular-iris space area (TISA) at 1, 3 and 6 months postoperatively. RESULTS: All 3 AC angle parameters were significantly reduced at the 1st postoperative month compared to preoperative values, but remained stable thereafter with no significant change at the 3rd or 6th postoperative months. The lens vault showed no significant change over the entire follow-up period. CONCLUSION: IPCL implantation is a safe method for correction of myopia with stable AC angle narrowing over the course of 6 months postoperatively as monitored using AS-OCT. |
format | Online Article Text |
id | pubmed-9314284 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Netherlands |
record_format | MEDLINE/PubMed |
spelling | pubmed-93142842022-07-27 Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes Mahmoud, Mohamed Salah El-Din Mohamed, Asmaa Anwar Zein, Hosny Ahmed Int Ophthalmol Original Paper PURPOSE: To evaluate the changes in the angle of the AC and lens vault after IPCL implantation by AS-OCT in myopic patients. METHODS: This was a prospective observational study involving 30 myopic eyes implanted with IPCL. AS-OCT was used to evaluate lens vault and AC angle parameters including anterior chamber angle, angle opening distance and trabecular-iris space area (TISA) at 1, 3 and 6 months postoperatively. RESULTS: All 3 AC angle parameters were significantly reduced at the 1st postoperative month compared to preoperative values, but remained stable thereafter with no significant change at the 3rd or 6th postoperative months. The lens vault showed no significant change over the entire follow-up period. CONCLUSION: IPCL implantation is a safe method for correction of myopia with stable AC angle narrowing over the course of 6 months postoperatively as monitored using AS-OCT. Springer Netherlands 2022-03-04 2022 /pmc/articles/PMC9314284/ /pubmed/35243558 http://dx.doi.org/10.1007/s10792-022-02244-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Mahmoud, Mohamed Salah El-Din Mohamed, Asmaa Anwar Zein, Hosny Ahmed Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes |
title | Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes |
title_full | Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes |
title_fullStr | Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes |
title_full_unstemmed | Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes |
title_short | Evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes |
title_sort | evaluation of the anterior chamber angle by anterior segment optical coherence tomography after implantable phakic contact lens implantation in myopic eyes |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9314284/ https://www.ncbi.nlm.nih.gov/pubmed/35243558 http://dx.doi.org/10.1007/s10792-022-02244-2 |
work_keys_str_mv | AT mahmoudmohamedsalaheldin evaluationoftheanteriorchamberanglebyanteriorsegmentopticalcoherencetomographyafterimplantablephakiccontactlensimplantationinmyopiceyes AT mohamedasmaaanwar evaluationoftheanteriorchamberanglebyanteriorsegmentopticalcoherencetomographyafterimplantablephakiccontactlensimplantationinmyopiceyes AT zeinhosnyahmed evaluationoftheanteriorchamberanglebyanteriorsegmentopticalcoherencetomographyafterimplantablephakiccontactlensimplantationinmyopiceyes |