Cargando…
Interobserver Agreement and Reference Intervals for Biventricular Myocardial Deformation in Full-Term, Healthy Newborns: A 2D Speckle-Tracking Echocardiography-Based Strain Analysis
Data regarding reference intervals for strain parameters derived from 2D speckle-tracking echocardiography in full-term newborns are limited and still under development. Our objectives were to establish the level of reproducibility and reference intervals in assessing myocardial function using 2D sp...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9315515/ https://www.ncbi.nlm.nih.gov/pubmed/35886472 http://dx.doi.org/10.3390/ijerph19148620 |
_version_ | 1784754581004091392 |
---|---|
author | Toma, Daniela Toganel, Rodica Fagarasan, Amalia Cucerea, Manuela Gabor-Miklosi, Dorottya Cerghit-Paler, Andreea Iurian, Diana-Ramona Gozar, Horea Moldovan, Elena Iancu, Mihaela Gozar, Liliana |
author_facet | Toma, Daniela Toganel, Rodica Fagarasan, Amalia Cucerea, Manuela Gabor-Miklosi, Dorottya Cerghit-Paler, Andreea Iurian, Diana-Ramona Gozar, Horea Moldovan, Elena Iancu, Mihaela Gozar, Liliana |
author_sort | Toma, Daniela |
collection | PubMed |
description | Data regarding reference intervals for strain parameters derived from 2D speckle-tracking echocardiography in full-term newborns are limited and still under development. Our objectives were to establish the level of reproducibility and reference intervals in assessing myocardial function using 2D speckle-tracking echocardiography for longitudinal and regional strain measurements. A total of 127 full-term newborns were examined to be included in the study, of which 103 were analyzed. We used two-dimensional acquisitions from apical four-chamber view of both ventricles and analyzed the autostrain function offline. We obtained interobserver agreement between the two observers ranging from good to excellent for all speckle-tracking parameters except for the strain of the medial portion of the left ventricle (LV) lateral wall and the strain measured on the basal portion of the inter-ventricular septum, which reflected a fair interobserver reproducibility (ICC = 0.52, 95% IC: 0.22–0.72 and ICC = 0.43, 95% IC: 0.12–0.67, respectively). The reference values obtained for the LV peak longitudinal strain were between −24.65 and −14.62, those for the right ventricle (RV) free wall were from −28.69 to −10.68, and those for the RV global four-chamber were from −22.30 to −11.37. In conclusion, two-dimensional peak longitudinal LV and RV strains are reproducible with good to excellent agreement and may represent a possible alternative for the cardiac assessment of healthy newborns in the clinical practice. |
format | Online Article Text |
id | pubmed-9315515 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93155152022-07-27 Interobserver Agreement and Reference Intervals for Biventricular Myocardial Deformation in Full-Term, Healthy Newborns: A 2D Speckle-Tracking Echocardiography-Based Strain Analysis Toma, Daniela Toganel, Rodica Fagarasan, Amalia Cucerea, Manuela Gabor-Miklosi, Dorottya Cerghit-Paler, Andreea Iurian, Diana-Ramona Gozar, Horea Moldovan, Elena Iancu, Mihaela Gozar, Liliana Int J Environ Res Public Health Article Data regarding reference intervals for strain parameters derived from 2D speckle-tracking echocardiography in full-term newborns are limited and still under development. Our objectives were to establish the level of reproducibility and reference intervals in assessing myocardial function using 2D speckle-tracking echocardiography for longitudinal and regional strain measurements. A total of 127 full-term newborns were examined to be included in the study, of which 103 were analyzed. We used two-dimensional acquisitions from apical four-chamber view of both ventricles and analyzed the autostrain function offline. We obtained interobserver agreement between the two observers ranging from good to excellent for all speckle-tracking parameters except for the strain of the medial portion of the left ventricle (LV) lateral wall and the strain measured on the basal portion of the inter-ventricular septum, which reflected a fair interobserver reproducibility (ICC = 0.52, 95% IC: 0.22–0.72 and ICC = 0.43, 95% IC: 0.12–0.67, respectively). The reference values obtained for the LV peak longitudinal strain were between −24.65 and −14.62, those for the right ventricle (RV) free wall were from −28.69 to −10.68, and those for the RV global four-chamber were from −22.30 to −11.37. In conclusion, two-dimensional peak longitudinal LV and RV strains are reproducible with good to excellent agreement and may represent a possible alternative for the cardiac assessment of healthy newborns in the clinical practice. MDPI 2022-07-15 /pmc/articles/PMC9315515/ /pubmed/35886472 http://dx.doi.org/10.3390/ijerph19148620 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Toma, Daniela Toganel, Rodica Fagarasan, Amalia Cucerea, Manuela Gabor-Miklosi, Dorottya Cerghit-Paler, Andreea Iurian, Diana-Ramona Gozar, Horea Moldovan, Elena Iancu, Mihaela Gozar, Liliana Interobserver Agreement and Reference Intervals for Biventricular Myocardial Deformation in Full-Term, Healthy Newborns: A 2D Speckle-Tracking Echocardiography-Based Strain Analysis |
title | Interobserver Agreement and Reference Intervals for Biventricular Myocardial Deformation in Full-Term, Healthy Newborns: A 2D Speckle-Tracking Echocardiography-Based Strain Analysis |
title_full | Interobserver Agreement and Reference Intervals for Biventricular Myocardial Deformation in Full-Term, Healthy Newborns: A 2D Speckle-Tracking Echocardiography-Based Strain Analysis |
title_fullStr | Interobserver Agreement and Reference Intervals for Biventricular Myocardial Deformation in Full-Term, Healthy Newborns: A 2D Speckle-Tracking Echocardiography-Based Strain Analysis |
title_full_unstemmed | Interobserver Agreement and Reference Intervals for Biventricular Myocardial Deformation in Full-Term, Healthy Newborns: A 2D Speckle-Tracking Echocardiography-Based Strain Analysis |
title_short | Interobserver Agreement and Reference Intervals for Biventricular Myocardial Deformation in Full-Term, Healthy Newborns: A 2D Speckle-Tracking Echocardiography-Based Strain Analysis |
title_sort | interobserver agreement and reference intervals for biventricular myocardial deformation in full-term, healthy newborns: a 2d speckle-tracking echocardiography-based strain analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9315515/ https://www.ncbi.nlm.nih.gov/pubmed/35886472 http://dx.doi.org/10.3390/ijerph19148620 |
work_keys_str_mv | AT tomadaniela interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT toganelrodica interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT fagarasanamalia interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT cucereamanuela interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT gabormiklosidorottya interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT cerghitpalerandreea interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT iuriandianaramona interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT gozarhorea interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT moldovanelena interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT iancumihaela interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis AT gozarliliana interobserveragreementandreferenceintervalsforbiventricularmyocardialdeformationinfulltermhealthynewbornsa2dspeckletrackingechocardiographybasedstrainanalysis |