New Sensors for Monitoring pH and Corrosion of Embedded Steel in Mortars during Sulfuric Acid Attack
The sulfuric acid attack is a common form of degradation of reinforced concrete in contact with industrial wastewater, mine water, acid rain, or in sewage treatment stations. In this work, new pH-sensitive IrOx electrodes were developed for monitoring the pH inside mortar or concrete. To test their...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9315610/ https://www.ncbi.nlm.nih.gov/pubmed/35891035 http://dx.doi.org/10.3390/s22145356 |
Sumario: | The sulfuric acid attack is a common form of degradation of reinforced concrete in contact with industrial wastewater, mine water, acid rain, or in sewage treatment stations. In this work, new pH-sensitive IrOx electrodes were developed for monitoring the pH inside mortar or concrete. To test their ability, the pH sensors were embedded in mortar samples at different depths and the samples were exposed to sulfuric acid solution. In another set of experiments, iron wires were placed at the same depths inside similar mortar samples and their corrosion was monitored as the acid attacked the mortar. Severe acid attack led to cement dissolution and formation of gypsum. The new pH sensors succeeded in measuring the pH changes inside the mortars. The pH gradient, from the high acid environment to the high alkaline mortar interior, occurred in a narrow region. Corrosion of the iron electrodes started only when the acidic solution was in their close vicinity. |
---|