Cargando…
Design of the Automated Calibration Process for an Experimental Laser Inspection Stand
This paper deals with the concept of the automated calibration design for inspection systems using laser sensors. The conceptual solution is based on using a laser sensor and its ability to scan 3D surfaces of inspected objects in order to create a representative point cloud. Problems of scanning ar...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9315713/ https://www.ncbi.nlm.nih.gov/pubmed/35890987 http://dx.doi.org/10.3390/s22145306 |
_version_ | 1784754630449692672 |
---|---|
author | Klarák, Jaromír Andok, Robert Hricko, Jaroslav Klačková, Ivana Tsai, Hung-Yin |
author_facet | Klarák, Jaromír Andok, Robert Hricko, Jaroslav Klačková, Ivana Tsai, Hung-Yin |
author_sort | Klarák, Jaromír |
collection | PubMed |
description | This paper deals with the concept of the automated calibration design for inspection systems using laser sensors. The conceptual solution is based on using a laser sensor and its ability to scan 3D surfaces of inspected objects in order to create a representative point cloud. Problems of scanning are briefly discussed. The automated calibration procedure for solving problems of errors due to non-precise adjustment of the mechanical arrangement, possible tolerances in assembly, and their following elimination is proposed. The main goal is to develop a system able to measure and quantify the quality of produced objects in the environment of Industry 4.0. Laboratory measurements on the experimental stand, including the principal software solution for automated calibration of laser sensors suitable for gear wheel inspection systems are presented. There is described design of compensation eccentricity by Fourier transform and sinusoidal fitting to identify and suppress the first harmonic component in the data with high precision measuring. |
format | Online Article Text |
id | pubmed-9315713 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93157132022-07-27 Design of the Automated Calibration Process for an Experimental Laser Inspection Stand Klarák, Jaromír Andok, Robert Hricko, Jaroslav Klačková, Ivana Tsai, Hung-Yin Sensors (Basel) Article This paper deals with the concept of the automated calibration design for inspection systems using laser sensors. The conceptual solution is based on using a laser sensor and its ability to scan 3D surfaces of inspected objects in order to create a representative point cloud. Problems of scanning are briefly discussed. The automated calibration procedure for solving problems of errors due to non-precise adjustment of the mechanical arrangement, possible tolerances in assembly, and their following elimination is proposed. The main goal is to develop a system able to measure and quantify the quality of produced objects in the environment of Industry 4.0. Laboratory measurements on the experimental stand, including the principal software solution for automated calibration of laser sensors suitable for gear wheel inspection systems are presented. There is described design of compensation eccentricity by Fourier transform and sinusoidal fitting to identify and suppress the first harmonic component in the data with high precision measuring. MDPI 2022-07-15 /pmc/articles/PMC9315713/ /pubmed/35890987 http://dx.doi.org/10.3390/s22145306 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Klarák, Jaromír Andok, Robert Hricko, Jaroslav Klačková, Ivana Tsai, Hung-Yin Design of the Automated Calibration Process for an Experimental Laser Inspection Stand |
title | Design of the Automated Calibration Process for an Experimental Laser Inspection Stand |
title_full | Design of the Automated Calibration Process for an Experimental Laser Inspection Stand |
title_fullStr | Design of the Automated Calibration Process for an Experimental Laser Inspection Stand |
title_full_unstemmed | Design of the Automated Calibration Process for an Experimental Laser Inspection Stand |
title_short | Design of the Automated Calibration Process for an Experimental Laser Inspection Stand |
title_sort | design of the automated calibration process for an experimental laser inspection stand |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9315713/ https://www.ncbi.nlm.nih.gov/pubmed/35890987 http://dx.doi.org/10.3390/s22145306 |
work_keys_str_mv | AT klarakjaromir designoftheautomatedcalibrationprocessforanexperimentallaserinspectionstand AT andokrobert designoftheautomatedcalibrationprocessforanexperimentallaserinspectionstand AT hrickojaroslav designoftheautomatedcalibrationprocessforanexperimentallaserinspectionstand AT klackovaivana designoftheautomatedcalibrationprocessforanexperimentallaserinspectionstand AT tsaihungyin designoftheautomatedcalibrationprocessforanexperimentallaserinspectionstand |