Cargando…

Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters

Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by...

Descripción completa

Detalles Bibliográficos
Autores principales: Massaad, Jack, van Neer, Paul L. M. J., van Willigen, Douwe M., Pertijs, Michiel A. P., de Jong, Nicolaas, Verweij, Martin D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9317834/
https://www.ncbi.nlm.nih.gov/pubmed/35890749
http://dx.doi.org/10.3390/s22145068
_version_ 1784755153698553856
author Massaad, Jack
van Neer, Paul L. M. J.
van Willigen, Douwe M.
Pertijs, Michiel A. P.
de Jong, Nicolaas
Verweij, Martin D.
author_facet Massaad, Jack
van Neer, Paul L. M. J.
van Willigen, Douwe M.
Pertijs, Michiel A. P.
de Jong, Nicolaas
Verweij, Martin D.
author_sort Massaad, Jack
collection PubMed
description Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe wall until the maximum amplitude of the relevant acoustic pulse is obtained. This process is time-consuming and operator-dependent. Next to this, at least five parameters of the pipe and the liquid need to be provided manually to compute the flow speed. In this work, a method is proposed to obtain the five parameters of the pipe and the liquid required to compute the flow speed. The method consists of obtaining the optimal angles for different wave travel paths by varying the steering angle of the emitted acoustic beam systematically. Based on these optimal angles, a system of equations is built and solved to extract the desired parameters. The proposed method was tested experimentally with a custom-made clamp-on UFM consisting of two linear arrays placed on a water-filled stainless steel pipe. The obtained parameters of the pipe and the liquid correspond very well with the expected (nominal) values. Furthermore, the performed experiment also demonstrates that a clamp-on UFM based on transducer arrays can achieve self-alignment without the need to manually move the transducers.
format Online
Article
Text
id pubmed-9317834
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93178342022-07-27 Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters Massaad, Jack van Neer, Paul L. M. J. van Willigen, Douwe M. Pertijs, Michiel A. P. de Jong, Nicolaas Verweij, Martin D. Sensors (Basel) Article Clamp-on ultrasonic flow meters (UFMs) are installed on the outside of the pipe wall. Typically, they consist of two single-element transducers mounted on angled wedges, which are acoustically coupled to the pipe wall. Before flow metering, the transducers are placed at the correct axial position by manually moving one transducer along the pipe wall until the maximum amplitude of the relevant acoustic pulse is obtained. This process is time-consuming and operator-dependent. Next to this, at least five parameters of the pipe and the liquid need to be provided manually to compute the flow speed. In this work, a method is proposed to obtain the five parameters of the pipe and the liquid required to compute the flow speed. The method consists of obtaining the optimal angles for different wave travel paths by varying the steering angle of the emitted acoustic beam systematically. Based on these optimal angles, a system of equations is built and solved to extract the desired parameters. The proposed method was tested experimentally with a custom-made clamp-on UFM consisting of two linear arrays placed on a water-filled stainless steel pipe. The obtained parameters of the pipe and the liquid correspond very well with the expected (nominal) values. Furthermore, the performed experiment also demonstrates that a clamp-on UFM based on transducer arrays can achieve self-alignment without the need to manually move the transducers. MDPI 2022-07-06 /pmc/articles/PMC9317834/ /pubmed/35890749 http://dx.doi.org/10.3390/s22145068 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Massaad, Jack
van Neer, Paul L. M. J.
van Willigen, Douwe M.
Pertijs, Michiel A. P.
de Jong, Nicolaas
Verweij, Martin D.
Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters
title Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters
title_full Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters
title_fullStr Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters
title_full_unstemmed Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters
title_short Measurement of Pipe and Liquid Parameters Using the Beam Steering Capabilities of Array-Based Clamp-On Ultrasonic Flow Meters
title_sort measurement of pipe and liquid parameters using the beam steering capabilities of array-based clamp-on ultrasonic flow meters
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9317834/
https://www.ncbi.nlm.nih.gov/pubmed/35890749
http://dx.doi.org/10.3390/s22145068
work_keys_str_mv AT massaadjack measurementofpipeandliquidparametersusingthebeamsteeringcapabilitiesofarraybasedclamponultrasonicflowmeters
AT vanneerpaullmj measurementofpipeandliquidparametersusingthebeamsteeringcapabilitiesofarraybasedclamponultrasonicflowmeters
AT vanwilligendouwem measurementofpipeandliquidparametersusingthebeamsteeringcapabilitiesofarraybasedclamponultrasonicflowmeters
AT pertijsmichielap measurementofpipeandliquidparametersusingthebeamsteeringcapabilitiesofarraybasedclamponultrasonicflowmeters
AT dejongnicolaas measurementofpipeandliquidparametersusingthebeamsteeringcapabilitiesofarraybasedclamponultrasonicflowmeters
AT verweijmartind measurementofpipeandliquidparametersusingthebeamsteeringcapabilitiesofarraybasedclamponultrasonicflowmeters