Cargando…

Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)

(1) Introduction: Optical coherence tomography (OCT) intravascular imaging facilitates percutaneous coronary intervention (PCI). Software for OCT is being constantly improved, including the latest version Ultreon™ 1.0 Software (U) (Abbott Vascular, Santa Clara, CA, USA). In the current analysis, we...

Descripción completa

Detalles Bibliográficos
Autores principales: Januszek, Rafał, Siłka, Wojciech, Sabatowski, Karol, Malinowski, Krzysztof Piotr, Heba, Grzegorz, Surowiec, Sławomir, Chyrchel, Michał, Rzeszutko, Łukasz, Bryniarski, Leszek, Surdacki, Andrzej, Bartuś, Krzysztof, Bartuś, Stanisław
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9318712/
https://www.ncbi.nlm.nih.gov/pubmed/35877580
http://dx.doi.org/10.3390/jcdd9070218
_version_ 1784755358400512000
author Januszek, Rafał
Siłka, Wojciech
Sabatowski, Karol
Malinowski, Krzysztof Piotr
Heba, Grzegorz
Surowiec, Sławomir
Chyrchel, Michał
Rzeszutko, Łukasz
Bryniarski, Leszek
Surdacki, Andrzej
Bartuś, Krzysztof
Bartuś, Stanisław
author_facet Januszek, Rafał
Siłka, Wojciech
Sabatowski, Karol
Malinowski, Krzysztof Piotr
Heba, Grzegorz
Surowiec, Sławomir
Chyrchel, Michał
Rzeszutko, Łukasz
Bryniarski, Leszek
Surdacki, Andrzej
Bartuś, Krzysztof
Bartuś, Stanisław
author_sort Januszek, Rafał
collection PubMed
description (1) Introduction: Optical coherence tomography (OCT) intravascular imaging facilitates percutaneous coronary intervention (PCI). Software for OCT is being constantly improved, including the latest version Ultreon™ 1.0 Software (U) (Abbott Vascular, Santa Clara, CA, USA). In the current analysis, we aim to compare processing results, procedural indices as well as clinical outcomes in patients treated via PCI. This was conducted using earlier generation OCT imaging software versions (non-U) and the newest available one on the market (U). (2) Methods: The study comprised 95 subsequent and not selected patients (55 processed with U and 40 non-U). The non-U processings were transferred for evaluation by U software, while the comparison of OCT parameters, selected clinical and procedural indices was performed between groups. We further assessed clinical outcomes during the follow-up period, i.e., major adverse cardiovascular events (MACE) and predictors of stent expansion. (3) Results: We did not detect any differences in general features between either of the assessed groups at baseline. Non-U software was more often used for bare-metal stenting (p = 0.004), while PCIs in the U group demanded a greater number of stents (p = 0.03). The distal reference of external elastic lamina (EEL) diameter was greater in the non-U group (p = 0.02) with no concurrent differences in minimal (p = 0.27) and maximal (p = 0.31) stent diameter. It was also observed that MACE was more frequently observed in the non-U group (p = 0.01). Neither univariable (estimate: 0.407, 95%CI: (−3.182) − 3.998, p = 0.82) nor multivariable (estimate: 2.29, 95%CI: (−4.207) − 8.788, p = 0.5) analyses demonstrated a relationship between the type of software and stent expansion. (4) Conclusions: Improvement in the software for image acquisition and processing of OCT is not related to stent expansion. The EEL diameter is preferably used to select the distal stent diameter in newer software.
format Online
Article
Text
id pubmed-9318712
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93187122022-07-27 Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software) Januszek, Rafał Siłka, Wojciech Sabatowski, Karol Malinowski, Krzysztof Piotr Heba, Grzegorz Surowiec, Sławomir Chyrchel, Michał Rzeszutko, Łukasz Bryniarski, Leszek Surdacki, Andrzej Bartuś, Krzysztof Bartuś, Stanisław J Cardiovasc Dev Dis Article (1) Introduction: Optical coherence tomography (OCT) intravascular imaging facilitates percutaneous coronary intervention (PCI). Software for OCT is being constantly improved, including the latest version Ultreon™ 1.0 Software (U) (Abbott Vascular, Santa Clara, CA, USA). In the current analysis, we aim to compare processing results, procedural indices as well as clinical outcomes in patients treated via PCI. This was conducted using earlier generation OCT imaging software versions (non-U) and the newest available one on the market (U). (2) Methods: The study comprised 95 subsequent and not selected patients (55 processed with U and 40 non-U). The non-U processings were transferred for evaluation by U software, while the comparison of OCT parameters, selected clinical and procedural indices was performed between groups. We further assessed clinical outcomes during the follow-up period, i.e., major adverse cardiovascular events (MACE) and predictors of stent expansion. (3) Results: We did not detect any differences in general features between either of the assessed groups at baseline. Non-U software was more often used for bare-metal stenting (p = 0.004), while PCIs in the U group demanded a greater number of stents (p = 0.03). The distal reference of external elastic lamina (EEL) diameter was greater in the non-U group (p = 0.02) with no concurrent differences in minimal (p = 0.27) and maximal (p = 0.31) stent diameter. It was also observed that MACE was more frequently observed in the non-U group (p = 0.01). Neither univariable (estimate: 0.407, 95%CI: (−3.182) − 3.998, p = 0.82) nor multivariable (estimate: 2.29, 95%CI: (−4.207) − 8.788, p = 0.5) analyses demonstrated a relationship between the type of software and stent expansion. (4) Conclusions: Improvement in the software for image acquisition and processing of OCT is not related to stent expansion. The EEL diameter is preferably used to select the distal stent diameter in newer software. MDPI 2022-07-06 /pmc/articles/PMC9318712/ /pubmed/35877580 http://dx.doi.org/10.3390/jcdd9070218 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Januszek, Rafał
Siłka, Wojciech
Sabatowski, Karol
Malinowski, Krzysztof Piotr
Heba, Grzegorz
Surowiec, Sławomir
Chyrchel, Michał
Rzeszutko, Łukasz
Bryniarski, Leszek
Surdacki, Andrzej
Bartuś, Krzysztof
Bartuś, Stanisław
Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)
title Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)
title_full Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)
title_fullStr Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)
title_full_unstemmed Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)
title_short Procedure-Related Differences and Clinical Outcomes in Patients Treated with Percutaneous Coronary Intervention Assisted by Optical Coherence Tomography between New and Earlier Generation Software (Ultreon™ 1.0 Software vs. AptiVue™ Software)
title_sort procedure-related differences and clinical outcomes in patients treated with percutaneous coronary intervention assisted by optical coherence tomography between new and earlier generation software (ultreon™ 1.0 software vs. aptivue™ software)
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9318712/
https://www.ncbi.nlm.nih.gov/pubmed/35877580
http://dx.doi.org/10.3390/jcdd9070218
work_keys_str_mv AT januszekrafał procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT siłkawojciech procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT sabatowskikarol procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT malinowskikrzysztofpiotr procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT hebagrzegorz procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT surowiecsławomir procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT chyrchelmichał procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT rzeszutkołukasz procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT bryniarskileszek procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT surdackiandrzej procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT bartuskrzysztof procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware
AT bartusstanisław procedurerelateddifferencesandclinicaloutcomesinpatientstreatedwithpercutaneouscoronaryinterventionassistedbyopticalcoherencetomographybetweennewandearliergenerationsoftwareultreon10softwarevsaptivuesoftware