Cargando…

A New Robotic Endoscope Holder for Ear and Sinus Surgery with an Integrated Safety Device

In the field of sinus and ear surgery, and more generally in microsurgery, the surgeon is faced with several challenges. The operations are traditionally carried out under binocular loupes, which allows for the surgeon to use both hands for a microinstrument and an aspiration tool. More recently, th...

Descripción completa

Detalles Bibliográficos
Autores principales: Michel, Guillaume, Bordure, Philippe, Chablat, Damien
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9319134/
https://www.ncbi.nlm.nih.gov/pubmed/35890855
http://dx.doi.org/10.3390/s22145175
_version_ 1784755475286327296
author Michel, Guillaume
Bordure, Philippe
Chablat, Damien
author_facet Michel, Guillaume
Bordure, Philippe
Chablat, Damien
author_sort Michel, Guillaume
collection PubMed
description In the field of sinus and ear surgery, and more generally in microsurgery, the surgeon is faced with several challenges. The operations are traditionally carried out under binocular loupes, which allows for the surgeon to use both hands for a microinstrument and an aspiration tool. More recently, the development of endoscopic otological surgery allowed for seeing areas that are difficult to access. However, the need to handle the endoscope reduces the surgeon’s ability to use only one instrument at a time. Thus, despite anaesthesia, patient motions during surgery can be very risky and are not that rare. Because the insertion zone in the middle ear or in the sinus cavity is very small, the mobility of the endoscope is limited to a rotation around a virtual point and a translation for the insertion of the camera. A mechanism with remote center motion (RCM) is a good candidate to achieve this movement and allow for the surgeon to access the ear or sinus. Since only the translational motion along the main insertion axis is enabled, the ejection motion along the same axis is safe for the patient. A specific mechanism allows for inserting and ejecting the endoscope. In a sense, the position is controlled, and the velocity is limited. In the opposite sense, the energy stored in the spring allows for very quick ejection if the patient moves. A prototype robot is presented using these new concepts. Commercially available components are used to enable initial tests to be carried out on synthetic bones to validate the mobility of the robot and its safety functions.
format Online
Article
Text
id pubmed-9319134
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93191342022-07-27 A New Robotic Endoscope Holder for Ear and Sinus Surgery with an Integrated Safety Device Michel, Guillaume Bordure, Philippe Chablat, Damien Sensors (Basel) Article In the field of sinus and ear surgery, and more generally in microsurgery, the surgeon is faced with several challenges. The operations are traditionally carried out under binocular loupes, which allows for the surgeon to use both hands for a microinstrument and an aspiration tool. More recently, the development of endoscopic otological surgery allowed for seeing areas that are difficult to access. However, the need to handle the endoscope reduces the surgeon’s ability to use only one instrument at a time. Thus, despite anaesthesia, patient motions during surgery can be very risky and are not that rare. Because the insertion zone in the middle ear or in the sinus cavity is very small, the mobility of the endoscope is limited to a rotation around a virtual point and a translation for the insertion of the camera. A mechanism with remote center motion (RCM) is a good candidate to achieve this movement and allow for the surgeon to access the ear or sinus. Since only the translational motion along the main insertion axis is enabled, the ejection motion along the same axis is safe for the patient. A specific mechanism allows for inserting and ejecting the endoscope. In a sense, the position is controlled, and the velocity is limited. In the opposite sense, the energy stored in the spring allows for very quick ejection if the patient moves. A prototype robot is presented using these new concepts. Commercially available components are used to enable initial tests to be carried out on synthetic bones to validate the mobility of the robot and its safety functions. MDPI 2022-07-11 /pmc/articles/PMC9319134/ /pubmed/35890855 http://dx.doi.org/10.3390/s22145175 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Michel, Guillaume
Bordure, Philippe
Chablat, Damien
A New Robotic Endoscope Holder for Ear and Sinus Surgery with an Integrated Safety Device
title A New Robotic Endoscope Holder for Ear and Sinus Surgery with an Integrated Safety Device
title_full A New Robotic Endoscope Holder for Ear and Sinus Surgery with an Integrated Safety Device
title_fullStr A New Robotic Endoscope Holder for Ear and Sinus Surgery with an Integrated Safety Device
title_full_unstemmed A New Robotic Endoscope Holder for Ear and Sinus Surgery with an Integrated Safety Device
title_short A New Robotic Endoscope Holder for Ear and Sinus Surgery with an Integrated Safety Device
title_sort new robotic endoscope holder for ear and sinus surgery with an integrated safety device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9319134/
https://www.ncbi.nlm.nih.gov/pubmed/35890855
http://dx.doi.org/10.3390/s22145175
work_keys_str_mv AT michelguillaume anewroboticendoscopeholderforearandsinussurgerywithanintegratedsafetydevice
AT bordurephilippe anewroboticendoscopeholderforearandsinussurgerywithanintegratedsafetydevice
AT chablatdamien anewroboticendoscopeholderforearandsinussurgerywithanintegratedsafetydevice
AT michelguillaume newroboticendoscopeholderforearandsinussurgerywithanintegratedsafetydevice
AT bordurephilippe newroboticendoscopeholderforearandsinussurgerywithanintegratedsafetydevice
AT chablatdamien newroboticendoscopeholderforearandsinussurgerywithanintegratedsafetydevice