Cargando…

Pupillometry as a Measure of Listening Effort in Patients with Bone-Anchored Hearing Systems

The goal of this study is to assess speech comprehension and listening effort by means of pupillometry, in patients with bone-anchored hearing system (BAHS). The study was performed prospectively in a group of 21 hearing-impaired adults, unilaterally implanted with BAHS Ponto. Listening effort was c...

Descripción completa

Detalles Bibliográficos
Autores principales: Gawęcki, Wojciech, Krzystanek, Katarzyna, Węgrzyniak, Magdalena, Gibasiewicz, Renata, Wierzbicka, Małgorzata
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9319729/
https://www.ncbi.nlm.nih.gov/pubmed/35887978
http://dx.doi.org/10.3390/jcm11144218
_version_ 1784755620754227200
author Gawęcki, Wojciech
Krzystanek, Katarzyna
Węgrzyniak, Magdalena
Gibasiewicz, Renata
Wierzbicka, Małgorzata
author_facet Gawęcki, Wojciech
Krzystanek, Katarzyna
Węgrzyniak, Magdalena
Gibasiewicz, Renata
Wierzbicka, Małgorzata
author_sort Gawęcki, Wojciech
collection PubMed
description The goal of this study is to assess speech comprehension and listening effort by means of pupillometry, in patients with bone-anchored hearing system (BAHS). The study was performed prospectively in a group of 21 hearing-impaired adults, unilaterally implanted with BAHS Ponto. Listening effort was compared in patients wearing two sound processors (Oticon Medical AB, Askim, Sweden): Ponto 3 SuperPower (P3SP) and Ponto Pro (PP). Every patient was invited to two visits, separated by a 3-month break. The first session was to establish the noise level needed to obtain 95% correct sentence recall in the hearing in noise test (HINT), when speech is presented at 70 dB SPL. During the second session, pupillometry, with the use of the above-mentioned conditions, was performed. The mean HINT scores obtained during the second visit were 96.3% for PP and 97.7% for P3SP (p = 0.9863). In pupillometry, no significant differences were found for average PPD (peak pupil dilation; p = 0.3247), average peak pupil dilation timing (p = 0.527) and for pupil dilation growth curves with both processors. The findings of this study suggest that BAHS users allocate similar listening effort with PP and P3SP when processing speech-in-noise at a sound pressure level not saturating Ponto Pro and at a fixed performance level of 95%. This finding applies to the patients who meet the qualification criteria for bone conduction devices and have BC in situ threshold average below 45 dB HL.
format Online
Article
Text
id pubmed-9319729
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93197292022-07-27 Pupillometry as a Measure of Listening Effort in Patients with Bone-Anchored Hearing Systems Gawęcki, Wojciech Krzystanek, Katarzyna Węgrzyniak, Magdalena Gibasiewicz, Renata Wierzbicka, Małgorzata J Clin Med Article The goal of this study is to assess speech comprehension and listening effort by means of pupillometry, in patients with bone-anchored hearing system (BAHS). The study was performed prospectively in a group of 21 hearing-impaired adults, unilaterally implanted with BAHS Ponto. Listening effort was compared in patients wearing two sound processors (Oticon Medical AB, Askim, Sweden): Ponto 3 SuperPower (P3SP) and Ponto Pro (PP). Every patient was invited to two visits, separated by a 3-month break. The first session was to establish the noise level needed to obtain 95% correct sentence recall in the hearing in noise test (HINT), when speech is presented at 70 dB SPL. During the second session, pupillometry, with the use of the above-mentioned conditions, was performed. The mean HINT scores obtained during the second visit were 96.3% for PP and 97.7% for P3SP (p = 0.9863). In pupillometry, no significant differences were found for average PPD (peak pupil dilation; p = 0.3247), average peak pupil dilation timing (p = 0.527) and for pupil dilation growth curves with both processors. The findings of this study suggest that BAHS users allocate similar listening effort with PP and P3SP when processing speech-in-noise at a sound pressure level not saturating Ponto Pro and at a fixed performance level of 95%. This finding applies to the patients who meet the qualification criteria for bone conduction devices and have BC in situ threshold average below 45 dB HL. MDPI 2022-07-20 /pmc/articles/PMC9319729/ /pubmed/35887978 http://dx.doi.org/10.3390/jcm11144218 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gawęcki, Wojciech
Krzystanek, Katarzyna
Węgrzyniak, Magdalena
Gibasiewicz, Renata
Wierzbicka, Małgorzata
Pupillometry as a Measure of Listening Effort in Patients with Bone-Anchored Hearing Systems
title Pupillometry as a Measure of Listening Effort in Patients with Bone-Anchored Hearing Systems
title_full Pupillometry as a Measure of Listening Effort in Patients with Bone-Anchored Hearing Systems
title_fullStr Pupillometry as a Measure of Listening Effort in Patients with Bone-Anchored Hearing Systems
title_full_unstemmed Pupillometry as a Measure of Listening Effort in Patients with Bone-Anchored Hearing Systems
title_short Pupillometry as a Measure of Listening Effort in Patients with Bone-Anchored Hearing Systems
title_sort pupillometry as a measure of listening effort in patients with bone-anchored hearing systems
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9319729/
https://www.ncbi.nlm.nih.gov/pubmed/35887978
http://dx.doi.org/10.3390/jcm11144218
work_keys_str_mv AT gaweckiwojciech pupillometryasameasureoflisteningeffortinpatientswithboneanchoredhearingsystems
AT krzystanekkatarzyna pupillometryasameasureoflisteningeffortinpatientswithboneanchoredhearingsystems
AT wegrzyniakmagdalena pupillometryasameasureoflisteningeffortinpatientswithboneanchoredhearingsystems
AT gibasiewiczrenata pupillometryasameasureoflisteningeffortinpatientswithboneanchoredhearingsystems
AT wierzbickamałgorzata pupillometryasameasureoflisteningeffortinpatientswithboneanchoredhearingsystems