Cargando…

Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode

(1) Objective: To scrutinize the reliability and the clinical value of routinely used fetal intelligent navigation echocardiography (FINE) static mode (5DHeartStatic™) for accelerated semiautomatic volumetric assessment of the normal fetal heart. (2) Methods: In this study, a total of 296 second and...

Descripción completa

Detalles Bibliográficos
Autores principales: Gembicki, Michael, Scharf, Jann Lennard, Dracopoulos, Christoph, Welp, Amrei, Weichert, Jan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9320472/
https://www.ncbi.nlm.nih.gov/pubmed/35887826
http://dx.doi.org/10.3390/jcm11144062
_version_ 1784755800431919104
author Gembicki, Michael
Scharf, Jann Lennard
Dracopoulos, Christoph
Welp, Amrei
Weichert, Jan
author_facet Gembicki, Michael
Scharf, Jann Lennard
Dracopoulos, Christoph
Welp, Amrei
Weichert, Jan
author_sort Gembicki, Michael
collection PubMed
description (1) Objective: To scrutinize the reliability and the clinical value of routinely used fetal intelligent navigation echocardiography (FINE) static mode (5DHeartStatic™) for accelerated semiautomatic volumetric assessment of the normal fetal heart. (2) Methods: In this study, a total of 296 second and third trimester fetuses were examined by targeted ultrasound. Spatiotemporal image correlation (STIC) volumes of the fetal heart were acquired for further volumetric assessment. In addition, all fetal hearts were scanned by a fast acquisition time volume (1 s). The volumes were analyzed using the FINE software. The data were investigated regarding the number of properly reconstructed planes and cardiac axis. (3) Results: A total of 257 volumes were included for final analysis. The mean gestational age (GA) was 23.9 weeks (14.3 to 37.7 weeks). In 96.9 (standard acquisition time, FINE standard mode) and 94.2% (fast acquisition time, FINE static mode) at least seven planes were reconstructed properly (p = 0.0961, not significant). Regarding the overall depiction rate, the standard mode was able to reconstruct 96.9% of the planes properly, whereas the static mode showed 95.2% of the planes (p = 0.0098). Moreover, there was no significant difference between the automatic measurement of the cardiac axis (37.95 + 9.14 vs. 38.00 + 8.92 degrees, p = 0.8827, not significant). (4) Conclusions: Based on our results, the FINE static mode technique is a reliable method. It provides similar information of the cardiac anatomy compared to conventional STIC volumes assessed by the FINE method. The FINE static mode has the potential to minimize the influence of motion artifacts during volume acquisition and might therefore be helpful concerning volumetric cardiac assessment in daily routine.
format Online
Article
Text
id pubmed-9320472
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93204722022-07-27 Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode Gembicki, Michael Scharf, Jann Lennard Dracopoulos, Christoph Welp, Amrei Weichert, Jan J Clin Med Article (1) Objective: To scrutinize the reliability and the clinical value of routinely used fetal intelligent navigation echocardiography (FINE) static mode (5DHeartStatic™) for accelerated semiautomatic volumetric assessment of the normal fetal heart. (2) Methods: In this study, a total of 296 second and third trimester fetuses were examined by targeted ultrasound. Spatiotemporal image correlation (STIC) volumes of the fetal heart were acquired for further volumetric assessment. In addition, all fetal hearts were scanned by a fast acquisition time volume (1 s). The volumes were analyzed using the FINE software. The data were investigated regarding the number of properly reconstructed planes and cardiac axis. (3) Results: A total of 257 volumes were included for final analysis. The mean gestational age (GA) was 23.9 weeks (14.3 to 37.7 weeks). In 96.9 (standard acquisition time, FINE standard mode) and 94.2% (fast acquisition time, FINE static mode) at least seven planes were reconstructed properly (p = 0.0961, not significant). Regarding the overall depiction rate, the standard mode was able to reconstruct 96.9% of the planes properly, whereas the static mode showed 95.2% of the planes (p = 0.0098). Moreover, there was no significant difference between the automatic measurement of the cardiac axis (37.95 + 9.14 vs. 38.00 + 8.92 degrees, p = 0.8827, not significant). (4) Conclusions: Based on our results, the FINE static mode technique is a reliable method. It provides similar information of the cardiac anatomy compared to conventional STIC volumes assessed by the FINE method. The FINE static mode has the potential to minimize the influence of motion artifacts during volume acquisition and might therefore be helpful concerning volumetric cardiac assessment in daily routine. MDPI 2022-07-14 /pmc/articles/PMC9320472/ /pubmed/35887826 http://dx.doi.org/10.3390/jcm11144062 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gembicki, Michael
Scharf, Jann Lennard
Dracopoulos, Christoph
Welp, Amrei
Weichert, Jan
Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode
title Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode
title_full Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode
title_fullStr Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode
title_full_unstemmed Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode
title_short Maximal Reduction of STIC Acquisition Time for Volumetric Assessment of the Fetal Heart—Benefits and Limitations of Semiautomatic Fetal Intelligent Navigation Echocardiography (FINE) Static Mode
title_sort maximal reduction of stic acquisition time for volumetric assessment of the fetal heart—benefits and limitations of semiautomatic fetal intelligent navigation echocardiography (fine) static mode
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9320472/
https://www.ncbi.nlm.nih.gov/pubmed/35887826
http://dx.doi.org/10.3390/jcm11144062
work_keys_str_mv AT gembickimichael maximalreductionofsticacquisitiontimeforvolumetricassessmentofthefetalheartbenefitsandlimitationsofsemiautomaticfetalintelligentnavigationechocardiographyfinestaticmode
AT scharfjannlennard maximalreductionofsticacquisitiontimeforvolumetricassessmentofthefetalheartbenefitsandlimitationsofsemiautomaticfetalintelligentnavigationechocardiographyfinestaticmode
AT dracopouloschristoph maximalreductionofsticacquisitiontimeforvolumetricassessmentofthefetalheartbenefitsandlimitationsofsemiautomaticfetalintelligentnavigationechocardiographyfinestaticmode
AT welpamrei maximalreductionofsticacquisitiontimeforvolumetricassessmentofthefetalheartbenefitsandlimitationsofsemiautomaticfetalintelligentnavigationechocardiographyfinestaticmode
AT weichertjan maximalreductionofsticacquisitiontimeforvolumetricassessmentofthefetalheartbenefitsandlimitationsofsemiautomaticfetalintelligentnavigationechocardiographyfinestaticmode