Cargando…
Compression generated by cortical screws in an artificial bone model of an equine medial femoral condylar cyst
OBJECTIVE: Determine compression generated by lag and neutral screws over 12 h using two bone analogs. STUDY DESIGN: Experimental study. SAMPLE POPULATION: Bone analogs were made of composite synthetic bone (CSB) or three‐dimensional printed polylactic acid (PLA). Analogs had a 2 mm exterior shell w...
Autores principales: | Moreno, Caitlin R., Santschi, Elizabeth M., Janes, Jennifer, Liu, Jie, Kim, Do‐Gyoon, Litsky, Alan S. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley & Sons, Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9321887/ https://www.ncbi.nlm.nih.gov/pubmed/35394080 http://dx.doi.org/10.1111/vsu.13814 |
Ejemplares similares
-
Maturation of the equine medial femoral condyle osteochondral unit
por: Lemirre, T., et al.
Publicado: (2020) -
Comparative endurance testing of the Biomet Matthews Nail and the Dynamic Compression Screw, in simulated condylar and supracondylar femoral fractures
por: O'Connor-Read, Laurence M, et al.
Publicado: (2008) -
Biomechanical comparison of dynamic condylar screw and locking compression plate fixation in unstable distal femoral fractures: An in vitro study
por: Singh, Ashutosh Kumar, et al.
Publicado: (2013) -
“Revision of subtrochanteric femoral nonunions after intramedullary nailing with dynamic condylar screw”
por: Lotzien, Sebastian, et al.
Publicado: (2018) -
Mechanical analysis of femoral neck fracture fixation with dynamic condylar screw in synthetic bone
por: Freitas, Anderson, et al.
Publicado: (2014)