Cargando…

Research on Mechanical Behavior of the Steel–Concrete–Steel Composite Structures Subjected to High Temperature of Fire

A new type of steel–concrete–steel composite structure was adopted and widely used in the immersed tunnel of the Shenzhen–Zhongshan access. The research on the mechanical behavior of the new composite structure under a high temperature of fire is of great engineering significance to the fire protect...

Descripción completa

Detalles Bibliográficos
Autores principales: Cao, Peng, Hu, Xuebing, Liu, Enlong, Chen, Jianzhong, Jiang, Shouchao, Ding, Hao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9321933/
https://www.ncbi.nlm.nih.gov/pubmed/35888339
http://dx.doi.org/10.3390/ma15144872
_version_ 1784756172961611776
author Cao, Peng
Hu, Xuebing
Liu, Enlong
Chen, Jianzhong
Jiang, Shouchao
Ding, Hao
author_facet Cao, Peng
Hu, Xuebing
Liu, Enlong
Chen, Jianzhong
Jiang, Shouchao
Ding, Hao
author_sort Cao, Peng
collection PubMed
description A new type of steel–concrete–steel composite structure was adopted and widely used in the immersed tunnel of the Shenzhen–Zhongshan access. The research on the mechanical behavior of the new composite structure under a high temperature of fire is of great engineering significance to the fire protection design of the structure. Both the model test and a numerical simulation were adopted to study the mechanical behavior and damage characteristics of the new composite structure under fire. The RABT standard temperature rise curve was used to simulate the temperature rising law under fire (it reflects the characteristics of temperature rise in case of fire in an enclosed environment: rapidly raised to 1200 °C within 5 min, maintained at 1200 °C for 120 min, then it is cooled to normal temperature after 110 min). The temperature distribution law inside the structure, the deformation development law of the roof and the crack distribution were analyzed based on the thermal–mechanical coupling analysis method. The results showed that the internal part of the composite structure close to the fire surface was directly affected by the high temperature, and the temperature presented a step distribution law, while the part far from the fire surface was affected by the lag effect of the temperature transfer, and the temperature presented a continuous growth law. The roof deformation presented a three-stage model of “rapid growth-deformation stability-deformation recovery” with time. The overall cracks of the composite structure showed a symmetrical distribution under fire. The composite structure presented a shear failure mode as a whole. The results could provide a reference for the study of fire resistance for the new composite structure and support the structural fire protection design of the immersed tunnel of the Shenzhen–Zhongshan access.
format Online
Article
Text
id pubmed-9321933
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93219332022-07-27 Research on Mechanical Behavior of the Steel–Concrete–Steel Composite Structures Subjected to High Temperature of Fire Cao, Peng Hu, Xuebing Liu, Enlong Chen, Jianzhong Jiang, Shouchao Ding, Hao Materials (Basel) Article A new type of steel–concrete–steel composite structure was adopted and widely used in the immersed tunnel of the Shenzhen–Zhongshan access. The research on the mechanical behavior of the new composite structure under a high temperature of fire is of great engineering significance to the fire protection design of the structure. Both the model test and a numerical simulation were adopted to study the mechanical behavior and damage characteristics of the new composite structure under fire. The RABT standard temperature rise curve was used to simulate the temperature rising law under fire (it reflects the characteristics of temperature rise in case of fire in an enclosed environment: rapidly raised to 1200 °C within 5 min, maintained at 1200 °C for 120 min, then it is cooled to normal temperature after 110 min). The temperature distribution law inside the structure, the deformation development law of the roof and the crack distribution were analyzed based on the thermal–mechanical coupling analysis method. The results showed that the internal part of the composite structure close to the fire surface was directly affected by the high temperature, and the temperature presented a step distribution law, while the part far from the fire surface was affected by the lag effect of the temperature transfer, and the temperature presented a continuous growth law. The roof deformation presented a three-stage model of “rapid growth-deformation stability-deformation recovery” with time. The overall cracks of the composite structure showed a symmetrical distribution under fire. The composite structure presented a shear failure mode as a whole. The results could provide a reference for the study of fire resistance for the new composite structure and support the structural fire protection design of the immersed tunnel of the Shenzhen–Zhongshan access. MDPI 2022-07-13 /pmc/articles/PMC9321933/ /pubmed/35888339 http://dx.doi.org/10.3390/ma15144872 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cao, Peng
Hu, Xuebing
Liu, Enlong
Chen, Jianzhong
Jiang, Shouchao
Ding, Hao
Research on Mechanical Behavior of the Steel–Concrete–Steel Composite Structures Subjected to High Temperature of Fire
title Research on Mechanical Behavior of the Steel–Concrete–Steel Composite Structures Subjected to High Temperature of Fire
title_full Research on Mechanical Behavior of the Steel–Concrete–Steel Composite Structures Subjected to High Temperature of Fire
title_fullStr Research on Mechanical Behavior of the Steel–Concrete–Steel Composite Structures Subjected to High Temperature of Fire
title_full_unstemmed Research on Mechanical Behavior of the Steel–Concrete–Steel Composite Structures Subjected to High Temperature of Fire
title_short Research on Mechanical Behavior of the Steel–Concrete–Steel Composite Structures Subjected to High Temperature of Fire
title_sort research on mechanical behavior of the steel–concrete–steel composite structures subjected to high temperature of fire
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9321933/
https://www.ncbi.nlm.nih.gov/pubmed/35888339
http://dx.doi.org/10.3390/ma15144872
work_keys_str_mv AT caopeng researchonmechanicalbehaviorofthesteelconcretesteelcompositestructuressubjectedtohightemperatureoffire
AT huxuebing researchonmechanicalbehaviorofthesteelconcretesteelcompositestructuressubjectedtohightemperatureoffire
AT liuenlong researchonmechanicalbehaviorofthesteelconcretesteelcompositestructuressubjectedtohightemperatureoffire
AT chenjianzhong researchonmechanicalbehaviorofthesteelconcretesteelcompositestructuressubjectedtohightemperatureoffire
AT jiangshouchao researchonmechanicalbehaviorofthesteelconcretesteelcompositestructuressubjectedtohightemperatureoffire
AT dinghao researchonmechanicalbehaviorofthesteelconcretesteelcompositestructuressubjectedtohightemperatureoffire