Cargando…

The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study

Intraoperative hypotension is associated with postoperative complications. However, in the majority of surgical patients, blood pressure (BP) is measured intermittently with a non-invasive cuff around the upper arm (NIBP-arm). We hypothesized that NIBP-arm, compared with a non-invasive continuous al...

Descripción completa

Detalles Bibliográficos
Autores principales: Wijnberge, Marije, van der Ster, Björn, Vlaar, Alexander P. J., Hollmann, Markus W., Geerts, Bart F., Veelo, Denise P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9321987/
https://www.ncbi.nlm.nih.gov/pubmed/35887844
http://dx.doi.org/10.3390/jcm11144083
_version_ 1784756185936691200
author Wijnberge, Marije
van der Ster, Björn
Vlaar, Alexander P. J.
Hollmann, Markus W.
Geerts, Bart F.
Veelo, Denise P.
author_facet Wijnberge, Marije
van der Ster, Björn
Vlaar, Alexander P. J.
Hollmann, Markus W.
Geerts, Bart F.
Veelo, Denise P.
author_sort Wijnberge, Marije
collection PubMed
description Intraoperative hypotension is associated with postoperative complications. However, in the majority of surgical patients, blood pressure (BP) is measured intermittently with a non-invasive cuff around the upper arm (NIBP-arm). We hypothesized that NIBP-arm, compared with a non-invasive continuous alternative, would result in missed events and in delayed recognition of hypotensive events. This was a sub-study of a previously published cohort study in adult patients undergoing surgery. The detection of hypotension (mean arterial pressure below 65 mmHg) was compared using two non-invasive methods; intermittent oscillometric NIBP-arm versus continuous NIBP measured with a finger cuff (cNIBP-finger) (Nexfin, Edwards Lifesciences). cNIBP-finger was used as the reference standard. Out of 350 patients, 268 patients (77%) had one or more hypotensive events during surgery. Out of the 286 patients, 72 (27%) had one or more missed hypotensive events. The majority of hypotensive events (92%) were detected with NIBP-arm, but were recognized at a median of 1.2 (0.6–2.2) minutes later. Intermittent BP monitoring resulted in missed hypotensive events and the hypotensive events that were detected were recognized with a delay. This study highlights the advantage of continuous monitoring. Future studies are needed to understand the effect on patient outcomes.
format Online
Article
Text
id pubmed-9321987
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93219872022-07-27 The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study Wijnberge, Marije van der Ster, Björn Vlaar, Alexander P. J. Hollmann, Markus W. Geerts, Bart F. Veelo, Denise P. J Clin Med Article Intraoperative hypotension is associated with postoperative complications. However, in the majority of surgical patients, blood pressure (BP) is measured intermittently with a non-invasive cuff around the upper arm (NIBP-arm). We hypothesized that NIBP-arm, compared with a non-invasive continuous alternative, would result in missed events and in delayed recognition of hypotensive events. This was a sub-study of a previously published cohort study in adult patients undergoing surgery. The detection of hypotension (mean arterial pressure below 65 mmHg) was compared using two non-invasive methods; intermittent oscillometric NIBP-arm versus continuous NIBP measured with a finger cuff (cNIBP-finger) (Nexfin, Edwards Lifesciences). cNIBP-finger was used as the reference standard. Out of 350 patients, 268 patients (77%) had one or more hypotensive events during surgery. Out of the 286 patients, 72 (27%) had one or more missed hypotensive events. The majority of hypotensive events (92%) were detected with NIBP-arm, but were recognized at a median of 1.2 (0.6–2.2) minutes later. Intermittent BP monitoring resulted in missed hypotensive events and the hypotensive events that were detected were recognized with a delay. This study highlights the advantage of continuous monitoring. Future studies are needed to understand the effect on patient outcomes. MDPI 2022-07-14 /pmc/articles/PMC9321987/ /pubmed/35887844 http://dx.doi.org/10.3390/jcm11144083 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wijnberge, Marije
van der Ster, Björn
Vlaar, Alexander P. J.
Hollmann, Markus W.
Geerts, Bart F.
Veelo, Denise P.
The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study
title The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study
title_full The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study
title_fullStr The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study
title_full_unstemmed The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study
title_short The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study
title_sort effect of intermittent versus continuous non-invasive blood pressure monitoring on the detection of intraoperative hypotension, a sub-study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9321987/
https://www.ncbi.nlm.nih.gov/pubmed/35887844
http://dx.doi.org/10.3390/jcm11144083
work_keys_str_mv AT wijnbergemarije theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT vandersterbjorn theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT vlaaralexanderpj theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT hollmannmarkusw theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT geertsbartf theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT veelodenisep theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT wijnbergemarije effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT vandersterbjorn effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT vlaaralexanderpj effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT hollmannmarkusw effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT geertsbartf effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy
AT veelodenisep effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy