Cargando…
The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study
Intraoperative hypotension is associated with postoperative complications. However, in the majority of surgical patients, blood pressure (BP) is measured intermittently with a non-invasive cuff around the upper arm (NIBP-arm). We hypothesized that NIBP-arm, compared with a non-invasive continuous al...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9321987/ https://www.ncbi.nlm.nih.gov/pubmed/35887844 http://dx.doi.org/10.3390/jcm11144083 |
_version_ | 1784756185936691200 |
---|---|
author | Wijnberge, Marije van der Ster, Björn Vlaar, Alexander P. J. Hollmann, Markus W. Geerts, Bart F. Veelo, Denise P. |
author_facet | Wijnberge, Marije van der Ster, Björn Vlaar, Alexander P. J. Hollmann, Markus W. Geerts, Bart F. Veelo, Denise P. |
author_sort | Wijnberge, Marije |
collection | PubMed |
description | Intraoperative hypotension is associated with postoperative complications. However, in the majority of surgical patients, blood pressure (BP) is measured intermittently with a non-invasive cuff around the upper arm (NIBP-arm). We hypothesized that NIBP-arm, compared with a non-invasive continuous alternative, would result in missed events and in delayed recognition of hypotensive events. This was a sub-study of a previously published cohort study in adult patients undergoing surgery. The detection of hypotension (mean arterial pressure below 65 mmHg) was compared using two non-invasive methods; intermittent oscillometric NIBP-arm versus continuous NIBP measured with a finger cuff (cNIBP-finger) (Nexfin, Edwards Lifesciences). cNIBP-finger was used as the reference standard. Out of 350 patients, 268 patients (77%) had one or more hypotensive events during surgery. Out of the 286 patients, 72 (27%) had one or more missed hypotensive events. The majority of hypotensive events (92%) were detected with NIBP-arm, but were recognized at a median of 1.2 (0.6–2.2) minutes later. Intermittent BP monitoring resulted in missed hypotensive events and the hypotensive events that were detected were recognized with a delay. This study highlights the advantage of continuous monitoring. Future studies are needed to understand the effect on patient outcomes. |
format | Online Article Text |
id | pubmed-9321987 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93219872022-07-27 The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study Wijnberge, Marije van der Ster, Björn Vlaar, Alexander P. J. Hollmann, Markus W. Geerts, Bart F. Veelo, Denise P. J Clin Med Article Intraoperative hypotension is associated with postoperative complications. However, in the majority of surgical patients, blood pressure (BP) is measured intermittently with a non-invasive cuff around the upper arm (NIBP-arm). We hypothesized that NIBP-arm, compared with a non-invasive continuous alternative, would result in missed events and in delayed recognition of hypotensive events. This was a sub-study of a previously published cohort study in adult patients undergoing surgery. The detection of hypotension (mean arterial pressure below 65 mmHg) was compared using two non-invasive methods; intermittent oscillometric NIBP-arm versus continuous NIBP measured with a finger cuff (cNIBP-finger) (Nexfin, Edwards Lifesciences). cNIBP-finger was used as the reference standard. Out of 350 patients, 268 patients (77%) had one or more hypotensive events during surgery. Out of the 286 patients, 72 (27%) had one or more missed hypotensive events. The majority of hypotensive events (92%) were detected with NIBP-arm, but were recognized at a median of 1.2 (0.6–2.2) minutes later. Intermittent BP monitoring resulted in missed hypotensive events and the hypotensive events that were detected were recognized with a delay. This study highlights the advantage of continuous monitoring. Future studies are needed to understand the effect on patient outcomes. MDPI 2022-07-14 /pmc/articles/PMC9321987/ /pubmed/35887844 http://dx.doi.org/10.3390/jcm11144083 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wijnberge, Marije van der Ster, Björn Vlaar, Alexander P. J. Hollmann, Markus W. Geerts, Bart F. Veelo, Denise P. The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study |
title | The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study |
title_full | The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study |
title_fullStr | The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study |
title_full_unstemmed | The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study |
title_short | The Effect of Intermittent versus Continuous Non-Invasive Blood Pressure Monitoring on the Detection of Intraoperative Hypotension, a Sub-Study |
title_sort | effect of intermittent versus continuous non-invasive blood pressure monitoring on the detection of intraoperative hypotension, a sub-study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9321987/ https://www.ncbi.nlm.nih.gov/pubmed/35887844 http://dx.doi.org/10.3390/jcm11144083 |
work_keys_str_mv | AT wijnbergemarije theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT vandersterbjorn theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT vlaaralexanderpj theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT hollmannmarkusw theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT geertsbartf theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT veelodenisep theeffectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT wijnbergemarije effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT vandersterbjorn effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT vlaaralexanderpj effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT hollmannmarkusw effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT geertsbartf effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy AT veelodenisep effectofintermittentversuscontinuousnoninvasivebloodpressuremonitoringonthedetectionofintraoperativehypotensionasubstudy |