Cargando…

Clinical Evidence on a Novel Macrohybrid Design Dental Implant with 12° Angled Platform: A Systematic Review

Background: Immediate implant placement with immediate esthetics has become a more common procedure over time, though ensuring good emergence of the axis of the implant has been a challenge. A novel macroimplant design with an angled platform (Co-Axis(®)) has been developed to ensure exit of the hea...

Descripción completa

Detalles Bibliográficos
Autores principales: Galve-Huertas, Andrea, Zilleruelo-Pozo, Maria José, García-González, Susana, Ortíz-Puigpelat, Octavi, Hernández-Alfaro, Federico, Aboul-Hosn Centenero, Samir
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9322499/
https://www.ncbi.nlm.nih.gov/pubmed/35888482
http://dx.doi.org/10.3390/ma15145011
_version_ 1784756319794757632
author Galve-Huertas, Andrea
Zilleruelo-Pozo, Maria José
García-González, Susana
Ortíz-Puigpelat, Octavi
Hernández-Alfaro, Federico
Aboul-Hosn Centenero, Samir
author_facet Galve-Huertas, Andrea
Zilleruelo-Pozo, Maria José
García-González, Susana
Ortíz-Puigpelat, Octavi
Hernández-Alfaro, Federico
Aboul-Hosn Centenero, Samir
author_sort Galve-Huertas, Andrea
collection PubMed
description Background: Immediate implant placement with immediate esthetics has become a more common procedure over time, though ensuring good emergence of the axis of the implant has been a challenge. A novel macroimplant design with an angled platform (Co-Axis(®)) has been developed to ensure exit of the head of the implant in the correct prosthetic position. A systematic literature review was carried to determine the survival rate and marginal bone loss associated with these implants. Material and Methods: An electronic and manual literature search was made in accordance with the PRISMA statement. The search strategy was limited to human studies, retrospective and prospective clinical trials, cross-sectional studies, and cohort studies reporting outcomes of a novel macrohybrid implant with a 12° angled implant connection. Results: Three articles met the inclusion criteria and were reviewed in the analysis. The estimated success rate was 95.9%. The global marginal bone loss was estimated to be −0.17 ± 0.58 mm in an environment characterized by great heterogeneity (I(2) = 99%). The estimated mean implant stability was 69.6 ± 0.92 (ISQ). As only two studies provided the required information, it was not possible to determine publication bias. Lastly, mean recession was estimated to be practically zero (0.06 ± 0.23 mm), with great heterogeneity. Conclusions: Within the limitations of this systematic review, it can be affirmed that immediate implant treatment with Co-Axis(®) implants shows a survival rate of 95.9% at one year of follow-up, with low marginal bone loss values, near-zero soft tissue recession, and favorable papilla index values. Nevertheless, the great heterogeneity of the data requires the findings to be interpreted with caution.
format Online
Article
Text
id pubmed-9322499
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93224992022-07-27 Clinical Evidence on a Novel Macrohybrid Design Dental Implant with 12° Angled Platform: A Systematic Review Galve-Huertas, Andrea Zilleruelo-Pozo, Maria José García-González, Susana Ortíz-Puigpelat, Octavi Hernández-Alfaro, Federico Aboul-Hosn Centenero, Samir Materials (Basel) Systematic Review Background: Immediate implant placement with immediate esthetics has become a more common procedure over time, though ensuring good emergence of the axis of the implant has been a challenge. A novel macroimplant design with an angled platform (Co-Axis(®)) has been developed to ensure exit of the head of the implant in the correct prosthetic position. A systematic literature review was carried to determine the survival rate and marginal bone loss associated with these implants. Material and Methods: An electronic and manual literature search was made in accordance with the PRISMA statement. The search strategy was limited to human studies, retrospective and prospective clinical trials, cross-sectional studies, and cohort studies reporting outcomes of a novel macrohybrid implant with a 12° angled implant connection. Results: Three articles met the inclusion criteria and were reviewed in the analysis. The estimated success rate was 95.9%. The global marginal bone loss was estimated to be −0.17 ± 0.58 mm in an environment characterized by great heterogeneity (I(2) = 99%). The estimated mean implant stability was 69.6 ± 0.92 (ISQ). As only two studies provided the required information, it was not possible to determine publication bias. Lastly, mean recession was estimated to be practically zero (0.06 ± 0.23 mm), with great heterogeneity. Conclusions: Within the limitations of this systematic review, it can be affirmed that immediate implant treatment with Co-Axis(®) implants shows a survival rate of 95.9% at one year of follow-up, with low marginal bone loss values, near-zero soft tissue recession, and favorable papilla index values. Nevertheless, the great heterogeneity of the data requires the findings to be interpreted with caution. MDPI 2022-07-19 /pmc/articles/PMC9322499/ /pubmed/35888482 http://dx.doi.org/10.3390/ma15145011 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Systematic Review
Galve-Huertas, Andrea
Zilleruelo-Pozo, Maria José
García-González, Susana
Ortíz-Puigpelat, Octavi
Hernández-Alfaro, Federico
Aboul-Hosn Centenero, Samir
Clinical Evidence on a Novel Macrohybrid Design Dental Implant with 12° Angled Platform: A Systematic Review
title Clinical Evidence on a Novel Macrohybrid Design Dental Implant with 12° Angled Platform: A Systematic Review
title_full Clinical Evidence on a Novel Macrohybrid Design Dental Implant with 12° Angled Platform: A Systematic Review
title_fullStr Clinical Evidence on a Novel Macrohybrid Design Dental Implant with 12° Angled Platform: A Systematic Review
title_full_unstemmed Clinical Evidence on a Novel Macrohybrid Design Dental Implant with 12° Angled Platform: A Systematic Review
title_short Clinical Evidence on a Novel Macrohybrid Design Dental Implant with 12° Angled Platform: A Systematic Review
title_sort clinical evidence on a novel macrohybrid design dental implant with 12° angled platform: a systematic review
topic Systematic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9322499/
https://www.ncbi.nlm.nih.gov/pubmed/35888482
http://dx.doi.org/10.3390/ma15145011
work_keys_str_mv AT galvehuertasandrea clinicalevidenceonanovelmacrohybriddesigndentalimplantwith12angledplatformasystematicreview
AT zilleruelopozomariajose clinicalevidenceonanovelmacrohybriddesigndentalimplantwith12angledplatformasystematicreview
AT garciagonzalezsusana clinicalevidenceonanovelmacrohybriddesigndentalimplantwith12angledplatformasystematicreview
AT ortizpuigpelatoctavi clinicalevidenceonanovelmacrohybriddesigndentalimplantwith12angledplatformasystematicreview
AT hernandezalfarofederico clinicalevidenceonanovelmacrohybriddesigndentalimplantwith12angledplatformasystematicreview
AT aboulhosncentenerosamir clinicalevidenceonanovelmacrohybriddesigndentalimplantwith12angledplatformasystematicreview