Cargando…

Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture

A rapid method for obtaining group B streptococcus (GBS) screening results has been required in the obstetric field. We aimed to determine the diagnostic performance of the Loop-Mediated Isothermal Amplification (LAMP) assay is acceptable compared to the existing polymerase chain reaction (PCR) assa...

Descripción completa

Detalles Bibliográficos
Autores principales: Sung, Ji-Hee, Cha, Hyun-Hwa, Lee, Nan-Young, Lee, Won-Ki, Choi, Yeseul, Han, Hyung-Soo, Lee, Yoo-Young, Chong, Gun-Oh, Seong, Won-Joon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9322697/
https://www.ncbi.nlm.nih.gov/pubmed/35885476
http://dx.doi.org/10.3390/diagnostics12071569
_version_ 1784756368762208256
author Sung, Ji-Hee
Cha, Hyun-Hwa
Lee, Nan-Young
Lee, Won-Ki
Choi, Yeseul
Han, Hyung-Soo
Lee, Yoo-Young
Chong, Gun-Oh
Seong, Won-Joon
author_facet Sung, Ji-Hee
Cha, Hyun-Hwa
Lee, Nan-Young
Lee, Won-Ki
Choi, Yeseul
Han, Hyung-Soo
Lee, Yoo-Young
Chong, Gun-Oh
Seong, Won-Joon
author_sort Sung, Ji-Hee
collection PubMed
description A rapid method for obtaining group B streptococcus (GBS) screening results has been required in the obstetric field. We aimed to determine the diagnostic performance of the Loop-Mediated Isothermal Amplification (LAMP) assay is acceptable compared to the existing polymerase chain reaction (PCR) assay. The study involved 527 pregnant women aged 19 to 44 years. Rectovaginal swabs were collected between 35 and 37 weeks of gestation or prior to impending preterm births or term labor without GBS screening. We presented the diagnostic performance of the LAMP assay with a 95% confidence interval (CI) compared to the PCR and microbiological culture. In total, 115 (21.8%), 115 (21.8%) and 23 (4.4%) patients showed positive results using the LAMP, PCR assay and microbiological culture method, respectively. The LAMP assay showed 100% sensitivity (95% CI, 96.8–100.0), 100% specificity (95% CI, 99.1–100.0) and 100% diagnostic accuracy (95% CI, 99.3–100.0) with the reference being the PCR assay. Meanwhile, the LAMP assay showed 87.0% sensitivity (95% CI, 71.0–100.0), 81.2% specificity (95% CI, 77.6–84.7), and 81.4% diagnostic accuracy (95% CI, 78.0–84.8) with the microbiological culture as a reference. This study presented the LAMP assay as an acceptable method for GBS screening with a similar performance to the existing PCR method.
format Online
Article
Text
id pubmed-9322697
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93226972022-07-27 Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture Sung, Ji-Hee Cha, Hyun-Hwa Lee, Nan-Young Lee, Won-Ki Choi, Yeseul Han, Hyung-Soo Lee, Yoo-Young Chong, Gun-Oh Seong, Won-Joon Diagnostics (Basel) Communication A rapid method for obtaining group B streptococcus (GBS) screening results has been required in the obstetric field. We aimed to determine the diagnostic performance of the Loop-Mediated Isothermal Amplification (LAMP) assay is acceptable compared to the existing polymerase chain reaction (PCR) assay. The study involved 527 pregnant women aged 19 to 44 years. Rectovaginal swabs were collected between 35 and 37 weeks of gestation or prior to impending preterm births or term labor without GBS screening. We presented the diagnostic performance of the LAMP assay with a 95% confidence interval (CI) compared to the PCR and microbiological culture. In total, 115 (21.8%), 115 (21.8%) and 23 (4.4%) patients showed positive results using the LAMP, PCR assay and microbiological culture method, respectively. The LAMP assay showed 100% sensitivity (95% CI, 96.8–100.0), 100% specificity (95% CI, 99.1–100.0) and 100% diagnostic accuracy (95% CI, 99.3–100.0) with the reference being the PCR assay. Meanwhile, the LAMP assay showed 87.0% sensitivity (95% CI, 71.0–100.0), 81.2% specificity (95% CI, 77.6–84.7), and 81.4% diagnostic accuracy (95% CI, 78.0–84.8) with the microbiological culture as a reference. This study presented the LAMP assay as an acceptable method for GBS screening with a similar performance to the existing PCR method. MDPI 2022-06-28 /pmc/articles/PMC9322697/ /pubmed/35885476 http://dx.doi.org/10.3390/diagnostics12071569 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Sung, Ji-Hee
Cha, Hyun-Hwa
Lee, Nan-Young
Lee, Won-Ki
Choi, Yeseul
Han, Hyung-Soo
Lee, Yoo-Young
Chong, Gun-Oh
Seong, Won-Joon
Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture
title Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture
title_full Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture
title_fullStr Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture
title_full_unstemmed Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture
title_short Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture
title_sort diagnostic accuracy of loop-mediated isothermal amplification assay for group b streptococcus detection in recto-vaginal swab: comparison with polymerase chain reaction test and conventional culture
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9322697/
https://www.ncbi.nlm.nih.gov/pubmed/35885476
http://dx.doi.org/10.3390/diagnostics12071569
work_keys_str_mv AT sungjihee diagnosticaccuracyofloopmediatedisothermalamplificationassayforgroupbstreptococcusdetectioninrectovaginalswabcomparisonwithpolymerasechainreactiontestandconventionalculture
AT chahyunhwa diagnosticaccuracyofloopmediatedisothermalamplificationassayforgroupbstreptococcusdetectioninrectovaginalswabcomparisonwithpolymerasechainreactiontestandconventionalculture
AT leenanyoung diagnosticaccuracyofloopmediatedisothermalamplificationassayforgroupbstreptococcusdetectioninrectovaginalswabcomparisonwithpolymerasechainreactiontestandconventionalculture
AT leewonki diagnosticaccuracyofloopmediatedisothermalamplificationassayforgroupbstreptococcusdetectioninrectovaginalswabcomparisonwithpolymerasechainreactiontestandconventionalculture
AT choiyeseul diagnosticaccuracyofloopmediatedisothermalamplificationassayforgroupbstreptococcusdetectioninrectovaginalswabcomparisonwithpolymerasechainreactiontestandconventionalculture
AT hanhyungsoo diagnosticaccuracyofloopmediatedisothermalamplificationassayforgroupbstreptococcusdetectioninrectovaginalswabcomparisonwithpolymerasechainreactiontestandconventionalculture
AT leeyooyoung diagnosticaccuracyofloopmediatedisothermalamplificationassayforgroupbstreptococcusdetectioninrectovaginalswabcomparisonwithpolymerasechainreactiontestandconventionalculture
AT chonggunoh diagnosticaccuracyofloopmediatedisothermalamplificationassayforgroupbstreptococcusdetectioninrectovaginalswabcomparisonwithpolymerasechainreactiontestandconventionalculture
AT seongwonjoon diagnosticaccuracyofloopmediatedisothermalamplificationassayforgroupbstreptococcusdetectioninrectovaginalswabcomparisonwithpolymerasechainreactiontestandconventionalculture