Cargando…
Diagnostic Accuracy of PET/CT or PET/MRI Using PSMA-Targeting Radiopharmaceuticals in High-Grade Gliomas: A Systematic Review and a Bivariate Meta-Analysis
Background: Several studies proposed the use of positron emission tomography (PET) with Prostate Specific Membrane Antigen (PSMA)-targeting radiopharmaceuticals in brain tumors. Our aim is to calculate the diagnostic accuracy of these methods in high-grade gliomas (HGG) with a bivariate meta-analysi...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9323081/ https://www.ncbi.nlm.nih.gov/pubmed/35885569 http://dx.doi.org/10.3390/diagnostics12071665 |
_version_ | 1784756462654849024 |
---|---|
author | Muoio, Barbara Albano, Domenico Dondi, Francesco Bertagna, Francesco Garibotto, Valentina Kunikowska, Jolanta Piccardo, Arnoldo Annunziata, Salvatore Espeli, Vittoria Migliorini, Denis Treglia, Giorgio |
author_facet | Muoio, Barbara Albano, Domenico Dondi, Francesco Bertagna, Francesco Garibotto, Valentina Kunikowska, Jolanta Piccardo, Arnoldo Annunziata, Salvatore Espeli, Vittoria Migliorini, Denis Treglia, Giorgio |
author_sort | Muoio, Barbara |
collection | PubMed |
description | Background: Several studies proposed the use of positron emission tomography (PET) with Prostate Specific Membrane Antigen (PSMA)-targeting radiopharmaceuticals in brain tumors. Our aim is to calculate the diagnostic accuracy of these methods in high-grade gliomas (HGG) with a bivariate meta-analysis. Methods: A comprehensive literature search of studies on the diagnostic accuracy of PET/CT or PET/MRI with PSMA-targeting radiopharmaceuticals in HGG was performed. Original articles evaluating these imaging methods both in the differential diagnosis between HGG and low-grade gliomas (LGG) and in the assessment of suspicious HGG recurrence were included. Pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-), and diagnostic odds ratio (DOR) including 95% confidence intervals (95% CI) were calculated. Statistical heterogeneity was also assessed using the I(2) test. Results: The meta-analysis of six selected studies (157 patients) provided the following results about PET/CT or PET/MRI with PSMA-targeting radiopharmaceuticals in the diagnosis of HGG: sensitivity 98.2% (95% CI: 75.3–99.9%), specificity 91.2% (95% CI: 68.4–98.1%), LR+ 4.5 (95% CI: 2.2–9.3), LR− 0.07 (95% CI: 0.04–0.15), and DOR 70.1 (95% CI: 19.6–250.9). No significant statistical heterogeneity among the included studies was found (I(2) = 0%). Conclusions: the quantitative data provided demonstrate the high diagnostic accuracy of PET/CT or PET/MRI with PSMA-targeting radiopharmaceuticals for HGG detection. However, more studies are needed to confirm the promising role of PSMA-targeted PET in this clinical setting. |
format | Online Article Text |
id | pubmed-9323081 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93230812022-07-27 Diagnostic Accuracy of PET/CT or PET/MRI Using PSMA-Targeting Radiopharmaceuticals in High-Grade Gliomas: A Systematic Review and a Bivariate Meta-Analysis Muoio, Barbara Albano, Domenico Dondi, Francesco Bertagna, Francesco Garibotto, Valentina Kunikowska, Jolanta Piccardo, Arnoldo Annunziata, Salvatore Espeli, Vittoria Migliorini, Denis Treglia, Giorgio Diagnostics (Basel) Systematic Review Background: Several studies proposed the use of positron emission tomography (PET) with Prostate Specific Membrane Antigen (PSMA)-targeting radiopharmaceuticals in brain tumors. Our aim is to calculate the diagnostic accuracy of these methods in high-grade gliomas (HGG) with a bivariate meta-analysis. Methods: A comprehensive literature search of studies on the diagnostic accuracy of PET/CT or PET/MRI with PSMA-targeting radiopharmaceuticals in HGG was performed. Original articles evaluating these imaging methods both in the differential diagnosis between HGG and low-grade gliomas (LGG) and in the assessment of suspicious HGG recurrence were included. Pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-), and diagnostic odds ratio (DOR) including 95% confidence intervals (95% CI) were calculated. Statistical heterogeneity was also assessed using the I(2) test. Results: The meta-analysis of six selected studies (157 patients) provided the following results about PET/CT or PET/MRI with PSMA-targeting radiopharmaceuticals in the diagnosis of HGG: sensitivity 98.2% (95% CI: 75.3–99.9%), specificity 91.2% (95% CI: 68.4–98.1%), LR+ 4.5 (95% CI: 2.2–9.3), LR− 0.07 (95% CI: 0.04–0.15), and DOR 70.1 (95% CI: 19.6–250.9). No significant statistical heterogeneity among the included studies was found (I(2) = 0%). Conclusions: the quantitative data provided demonstrate the high diagnostic accuracy of PET/CT or PET/MRI with PSMA-targeting radiopharmaceuticals for HGG detection. However, more studies are needed to confirm the promising role of PSMA-targeted PET in this clinical setting. MDPI 2022-07-08 /pmc/articles/PMC9323081/ /pubmed/35885569 http://dx.doi.org/10.3390/diagnostics12071665 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Systematic Review Muoio, Barbara Albano, Domenico Dondi, Francesco Bertagna, Francesco Garibotto, Valentina Kunikowska, Jolanta Piccardo, Arnoldo Annunziata, Salvatore Espeli, Vittoria Migliorini, Denis Treglia, Giorgio Diagnostic Accuracy of PET/CT or PET/MRI Using PSMA-Targeting Radiopharmaceuticals in High-Grade Gliomas: A Systematic Review and a Bivariate Meta-Analysis |
title | Diagnostic Accuracy of PET/CT or PET/MRI Using PSMA-Targeting Radiopharmaceuticals in High-Grade Gliomas: A Systematic Review and a Bivariate Meta-Analysis |
title_full | Diagnostic Accuracy of PET/CT or PET/MRI Using PSMA-Targeting Radiopharmaceuticals in High-Grade Gliomas: A Systematic Review and a Bivariate Meta-Analysis |
title_fullStr | Diagnostic Accuracy of PET/CT or PET/MRI Using PSMA-Targeting Radiopharmaceuticals in High-Grade Gliomas: A Systematic Review and a Bivariate Meta-Analysis |
title_full_unstemmed | Diagnostic Accuracy of PET/CT or PET/MRI Using PSMA-Targeting Radiopharmaceuticals in High-Grade Gliomas: A Systematic Review and a Bivariate Meta-Analysis |
title_short | Diagnostic Accuracy of PET/CT or PET/MRI Using PSMA-Targeting Radiopharmaceuticals in High-Grade Gliomas: A Systematic Review and a Bivariate Meta-Analysis |
title_sort | diagnostic accuracy of pet/ct or pet/mri using psma-targeting radiopharmaceuticals in high-grade gliomas: a systematic review and a bivariate meta-analysis |
topic | Systematic Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9323081/ https://www.ncbi.nlm.nih.gov/pubmed/35885569 http://dx.doi.org/10.3390/diagnostics12071665 |
work_keys_str_mv | AT muoiobarbara diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT albanodomenico diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT dondifrancesco diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT bertagnafrancesco diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT garibottovalentina diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT kunikowskajolanta diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT piccardoarnoldo diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT annunziatasalvatore diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT espelivittoria diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT migliorinidenis diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis AT tregliagiorgio diagnosticaccuracyofpetctorpetmriusingpsmatargetingradiopharmaceuticalsinhighgradegliomasasystematicreviewandabivariatemetaanalysis |