Cargando…

Low‐rank inversion reconstruction for through‐plane accelerated radial MR fingerprinting applied to relaxometry at 0.35 T

PURPOSE: To reduce scan time, methods to accelerate phase‐encoded/non‐Cartesian MR fingerprinting (MRF) acquisitions for variable density spiral acquisitions have recently been developed. These methods are not applicable to MRF acquisitions, wherein a single k‐space spoke is acquired per frame. Ther...

Descripción completa

Detalles Bibliográficos
Autores principales: Mickevicius, Nikolai J., Glide‐Hurst, Carri K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324087/
https://www.ncbi.nlm.nih.gov/pubmed/35403235
http://dx.doi.org/10.1002/mrm.29244
_version_ 1784756721165533184
author Mickevicius, Nikolai J.
Glide‐Hurst, Carri K.
author_facet Mickevicius, Nikolai J.
Glide‐Hurst, Carri K.
author_sort Mickevicius, Nikolai J.
collection PubMed
description PURPOSE: To reduce scan time, methods to accelerate phase‐encoded/non‐Cartesian MR fingerprinting (MRF) acquisitions for variable density spiral acquisitions have recently been developed. These methods are not applicable to MRF acquisitions, wherein a single k‐space spoke is acquired per frame. Therefore, we propose a low‐rank inversion method to resolve MRF contrast dynamics from through‐plane accelerated Cartesian/radial measurements applied to quantitative relaxation‐time mapping on a 0.35T system. METHODS: An algorithm was implemented to reconstruct through‐plane aliased low‐rank images describing the contrast dynamics occurring because of the transient‐state MRF acquisition. T(1) and T(2) times from accelerated acquisitions were compared with those from unaccelerated linear reconstructions in a standardized system phantom and within in vivo brain and prostate experiments on a hybrid 0.35T MRI/linear accelerator. RESULTS: No significant differences between T(1) and T(2) times for the accelerated reconstructions were observed compared to fully sampled acquisitions (p = 0.41 and p = 0.36, respectively). The mean absolute errors in T(1) and T(2) were 5.6% and 2.9%, respectively, between the full and accelerated acquisitions. The SDs in T(1) and T(2) decreased with the advanced accelerated reconstruction compared with the unaccelerated reconstruction (p = 0.02 and p = 0.03, respectively). The quality of the T(1) and T(2) maps generated with the proposed approach are comparable to those obtained using the unaccelerated data sets. CONCLUSIONS: Through‐plane accelerated MRF with radial k‐space coverage was demonstrated at a low field strength of 0.35 T. This method enabled 3D T(1) and T(2) mapping at 0.35 T with a 3‐min scan.
format Online
Article
Text
id pubmed-9324087
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-93240872022-07-30 Low‐rank inversion reconstruction for through‐plane accelerated radial MR fingerprinting applied to relaxometry at 0.35 T Mickevicius, Nikolai J. Glide‐Hurst, Carri K. Magn Reson Med Technical Notes–Imaging Methodology PURPOSE: To reduce scan time, methods to accelerate phase‐encoded/non‐Cartesian MR fingerprinting (MRF) acquisitions for variable density spiral acquisitions have recently been developed. These methods are not applicable to MRF acquisitions, wherein a single k‐space spoke is acquired per frame. Therefore, we propose a low‐rank inversion method to resolve MRF contrast dynamics from through‐plane accelerated Cartesian/radial measurements applied to quantitative relaxation‐time mapping on a 0.35T system. METHODS: An algorithm was implemented to reconstruct through‐plane aliased low‐rank images describing the contrast dynamics occurring because of the transient‐state MRF acquisition. T(1) and T(2) times from accelerated acquisitions were compared with those from unaccelerated linear reconstructions in a standardized system phantom and within in vivo brain and prostate experiments on a hybrid 0.35T MRI/linear accelerator. RESULTS: No significant differences between T(1) and T(2) times for the accelerated reconstructions were observed compared to fully sampled acquisitions (p = 0.41 and p = 0.36, respectively). The mean absolute errors in T(1) and T(2) were 5.6% and 2.9%, respectively, between the full and accelerated acquisitions. The SDs in T(1) and T(2) decreased with the advanced accelerated reconstruction compared with the unaccelerated reconstruction (p = 0.02 and p = 0.03, respectively). The quality of the T(1) and T(2) maps generated with the proposed approach are comparable to those obtained using the unaccelerated data sets. CONCLUSIONS: Through‐plane accelerated MRF with radial k‐space coverage was demonstrated at a low field strength of 0.35 T. This method enabled 3D T(1) and T(2) mapping at 0.35 T with a 3‐min scan. John Wiley and Sons Inc. 2022-04-10 2022-08 /pmc/articles/PMC9324087/ /pubmed/35403235 http://dx.doi.org/10.1002/mrm.29244 Text en © 2022 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes–Imaging Methodology
Mickevicius, Nikolai J.
Glide‐Hurst, Carri K.
Low‐rank inversion reconstruction for through‐plane accelerated radial MR fingerprinting applied to relaxometry at 0.35 T
title Low‐rank inversion reconstruction for through‐plane accelerated radial MR fingerprinting applied to relaxometry at 0.35 T
title_full Low‐rank inversion reconstruction for through‐plane accelerated radial MR fingerprinting applied to relaxometry at 0.35 T
title_fullStr Low‐rank inversion reconstruction for through‐plane accelerated radial MR fingerprinting applied to relaxometry at 0.35 T
title_full_unstemmed Low‐rank inversion reconstruction for through‐plane accelerated radial MR fingerprinting applied to relaxometry at 0.35 T
title_short Low‐rank inversion reconstruction for through‐plane accelerated radial MR fingerprinting applied to relaxometry at 0.35 T
title_sort low‐rank inversion reconstruction for through‐plane accelerated radial mr fingerprinting applied to relaxometry at 0.35 t
topic Technical Notes–Imaging Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324087/
https://www.ncbi.nlm.nih.gov/pubmed/35403235
http://dx.doi.org/10.1002/mrm.29244
work_keys_str_mv AT mickeviciusnikolaij lowrankinversionreconstructionforthroughplaneacceleratedradialmrfingerprintingappliedtorelaxometryat035t
AT glidehurstcarrik lowrankinversionreconstructionforthroughplaneacceleratedradialmrfingerprintingappliedtorelaxometryat035t