Cargando…

Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics

A monolithic microfluidic free-flow electrophoresis device, fabricated using low-temperature co-fired ceramic technology, is presented. The device integrates gold electrodes and a 20 µm thick transparent ceramic optical window, suitable for fluorescence imaging, into a multilevel microfluidic chambe...

Descripción completa

Detalles Bibliográficos
Autores principales: Couceiro, Pedro, Alonso-Chamarro, Julián
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324176/
https://www.ncbi.nlm.nih.gov/pubmed/35888840
http://dx.doi.org/10.3390/mi13071023
_version_ 1784756743291535360
author Couceiro, Pedro
Alonso-Chamarro, Julián
author_facet Couceiro, Pedro
Alonso-Chamarro, Julián
author_sort Couceiro, Pedro
collection PubMed
description A monolithic microfluidic free-flow electrophoresis device, fabricated using low-temperature co-fired ceramic technology, is presented. The device integrates gold electrodes and a 20 µm thick transparent ceramic optical window, suitable for fluorescence imaging, into a multilevel microfluidic chamber design. The microfluidic chamber consists of a 60 µm deep separation chamber and two, 50 µm deep electrode chambers separated by 10 µm deep side channel arrays. Fluorescence imaging was used for in-chip, spatial-temporal characterization of local pH variations in separation conditions as well as to characterize the separation process. The device allowed baseline resolution separation of a sample mixture of Fluorescein, Rhodamine 6G, and 4-Methylumbelliferone at pH 7.0, in only 6 s, using 378 V.s/cm. The results demonstrate the possibility of studying a chemical process using fluorescence imaging within the traditional fields of low-temperature co-fired ceramics technology, such as high-electrical-field applications, while using a simple fabrication procedure suitable for low-cost mass production.
format Online
Article
Text
id pubmed-9324176
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93241762022-07-27 Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics Couceiro, Pedro Alonso-Chamarro, Julián Micromachines (Basel) Article A monolithic microfluidic free-flow electrophoresis device, fabricated using low-temperature co-fired ceramic technology, is presented. The device integrates gold electrodes and a 20 µm thick transparent ceramic optical window, suitable for fluorescence imaging, into a multilevel microfluidic chamber design. The microfluidic chamber consists of a 60 µm deep separation chamber and two, 50 µm deep electrode chambers separated by 10 µm deep side channel arrays. Fluorescence imaging was used for in-chip, spatial-temporal characterization of local pH variations in separation conditions as well as to characterize the separation process. The device allowed baseline resolution separation of a sample mixture of Fluorescein, Rhodamine 6G, and 4-Methylumbelliferone at pH 7.0, in only 6 s, using 378 V.s/cm. The results demonstrate the possibility of studying a chemical process using fluorescence imaging within the traditional fields of low-temperature co-fired ceramics technology, such as high-electrical-field applications, while using a simple fabrication procedure suitable for low-cost mass production. MDPI 2022-06-28 /pmc/articles/PMC9324176/ /pubmed/35888840 http://dx.doi.org/10.3390/mi13071023 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Couceiro, Pedro
Alonso-Chamarro, Julián
Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics
title Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics
title_full Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics
title_fullStr Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics
title_full_unstemmed Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics
title_short Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics
title_sort fluorescence imaging characterization of the separation process in a monolithic microfluidic free-flow electrophoresis device fabricated using low-temperature co-fired ceramics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324176/
https://www.ncbi.nlm.nih.gov/pubmed/35888840
http://dx.doi.org/10.3390/mi13071023
work_keys_str_mv AT couceiropedro fluorescenceimagingcharacterizationoftheseparationprocessinamonolithicmicrofluidicfreeflowelectrophoresisdevicefabricatedusinglowtemperaturecofiredceramics
AT alonsochamarrojulian fluorescenceimagingcharacterizationoftheseparationprocessinamonolithicmicrofluidicfreeflowelectrophoresisdevicefabricatedusinglowtemperaturecofiredceramics