Cargando…
Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics
A monolithic microfluidic free-flow electrophoresis device, fabricated using low-temperature co-fired ceramic technology, is presented. The device integrates gold electrodes and a 20 µm thick transparent ceramic optical window, suitable for fluorescence imaging, into a multilevel microfluidic chambe...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324176/ https://www.ncbi.nlm.nih.gov/pubmed/35888840 http://dx.doi.org/10.3390/mi13071023 |
_version_ | 1784756743291535360 |
---|---|
author | Couceiro, Pedro Alonso-Chamarro, Julián |
author_facet | Couceiro, Pedro Alonso-Chamarro, Julián |
author_sort | Couceiro, Pedro |
collection | PubMed |
description | A monolithic microfluidic free-flow electrophoresis device, fabricated using low-temperature co-fired ceramic technology, is presented. The device integrates gold electrodes and a 20 µm thick transparent ceramic optical window, suitable for fluorescence imaging, into a multilevel microfluidic chamber design. The microfluidic chamber consists of a 60 µm deep separation chamber and two, 50 µm deep electrode chambers separated by 10 µm deep side channel arrays. Fluorescence imaging was used for in-chip, spatial-temporal characterization of local pH variations in separation conditions as well as to characterize the separation process. The device allowed baseline resolution separation of a sample mixture of Fluorescein, Rhodamine 6G, and 4-Methylumbelliferone at pH 7.0, in only 6 s, using 378 V.s/cm. The results demonstrate the possibility of studying a chemical process using fluorescence imaging within the traditional fields of low-temperature co-fired ceramics technology, such as high-electrical-field applications, while using a simple fabrication procedure suitable for low-cost mass production. |
format | Online Article Text |
id | pubmed-9324176 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93241762022-07-27 Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics Couceiro, Pedro Alonso-Chamarro, Julián Micromachines (Basel) Article A monolithic microfluidic free-flow electrophoresis device, fabricated using low-temperature co-fired ceramic technology, is presented. The device integrates gold electrodes and a 20 µm thick transparent ceramic optical window, suitable for fluorescence imaging, into a multilevel microfluidic chamber design. The microfluidic chamber consists of a 60 µm deep separation chamber and two, 50 µm deep electrode chambers separated by 10 µm deep side channel arrays. Fluorescence imaging was used for in-chip, spatial-temporal characterization of local pH variations in separation conditions as well as to characterize the separation process. The device allowed baseline resolution separation of a sample mixture of Fluorescein, Rhodamine 6G, and 4-Methylumbelliferone at pH 7.0, in only 6 s, using 378 V.s/cm. The results demonstrate the possibility of studying a chemical process using fluorescence imaging within the traditional fields of low-temperature co-fired ceramics technology, such as high-electrical-field applications, while using a simple fabrication procedure suitable for low-cost mass production. MDPI 2022-06-28 /pmc/articles/PMC9324176/ /pubmed/35888840 http://dx.doi.org/10.3390/mi13071023 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Couceiro, Pedro Alonso-Chamarro, Julián Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics |
title | Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics |
title_full | Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics |
title_fullStr | Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics |
title_full_unstemmed | Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics |
title_short | Fluorescence Imaging Characterization of the Separation Process in a Monolithic Microfluidic Free-Flow Electrophoresis Device Fabricated Using Low-Temperature Co-Fired Ceramics |
title_sort | fluorescence imaging characterization of the separation process in a monolithic microfluidic free-flow electrophoresis device fabricated using low-temperature co-fired ceramics |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324176/ https://www.ncbi.nlm.nih.gov/pubmed/35888840 http://dx.doi.org/10.3390/mi13071023 |
work_keys_str_mv | AT couceiropedro fluorescenceimagingcharacterizationoftheseparationprocessinamonolithicmicrofluidicfreeflowelectrophoresisdevicefabricatedusinglowtemperaturecofiredceramics AT alonsochamarrojulian fluorescenceimagingcharacterizationoftheseparationprocessinamonolithicmicrofluidicfreeflowelectrophoresisdevicefabricatedusinglowtemperaturecofiredceramics |