Cargando…
A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image
Pedicle screw insertion is considered a complex surgery among Orthopaedics surgeons. Exclusively to prevent postoperative complications associated with pedicle screw insertion, various types of image intensity registration-based navigation systems have been developed. These systems are computation-i...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324544/ https://www.ncbi.nlm.nih.gov/pubmed/35877629 http://dx.doi.org/10.3390/jimaging8070185 |
_version_ | 1784756833509965824 |
---|---|
author | Naik, Roshan Ramakrishna Hoblidar, Anitha Bhat, Shyamasunder N. Ampar, Nishanth Kundangar, Raghuraj |
author_facet | Naik, Roshan Ramakrishna Hoblidar, Anitha Bhat, Shyamasunder N. Ampar, Nishanth Kundangar, Raghuraj |
author_sort | Naik, Roshan Ramakrishna |
collection | PubMed |
description | Pedicle screw insertion is considered a complex surgery among Orthopaedics surgeons. Exclusively to prevent postoperative complications associated with pedicle screw insertion, various types of image intensity registration-based navigation systems have been developed. These systems are computation-intensive, have a small capture range and have local maxima issues. On the other hand, deep learning-based techniques lack registration generalizability and have data dependency. To overcome these limitations, a patient-specific hybrid 3D-2D registration principled framework was designed to map a pedicle screw trajectory between intraoperative X-ray image and preoperative CT image. An anatomical landmark-based 3D-2D Iterative Control Point (ICP) registration was performed to register a pedicular marker pose between the X-ray images and axial preoperative CT images. The registration framework was clinically validated by generating projection images possessing an optimal match with intraoperative X-ray images at the corresponding control point registration. The effectiveness of the registered trajectory was evaluated in terms of displacement and directional errors after reprojecting its position on 2D radiographic planes. The mean Euclidean distances for the Head and Tail end of the reprojected trajectory from the actual trajectory in the AP and lateral planes were shown to be 0.6–0.8 mm and 0.5–1.6 mm, respectively. Similarly, the corresponding mean directional errors were found to be [Formula: see text] and [Formula: see text]. The mean trajectory length difference between the actual and registered trajectory was shown to be 2.67 mm. The approximate time required in the intraoperative environment to axially map the marker position for a single vertebra was found to be 3 min. Utilizing the markerless registration techniques, the designed framework functions like a screw navigation tool, and assures the quality of surgery being performed by limiting the need of postoperative CT. |
format | Online Article Text |
id | pubmed-9324544 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93245442022-07-27 A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image Naik, Roshan Ramakrishna Hoblidar, Anitha Bhat, Shyamasunder N. Ampar, Nishanth Kundangar, Raghuraj J Imaging Article Pedicle screw insertion is considered a complex surgery among Orthopaedics surgeons. Exclusively to prevent postoperative complications associated with pedicle screw insertion, various types of image intensity registration-based navigation systems have been developed. These systems are computation-intensive, have a small capture range and have local maxima issues. On the other hand, deep learning-based techniques lack registration generalizability and have data dependency. To overcome these limitations, a patient-specific hybrid 3D-2D registration principled framework was designed to map a pedicle screw trajectory between intraoperative X-ray image and preoperative CT image. An anatomical landmark-based 3D-2D Iterative Control Point (ICP) registration was performed to register a pedicular marker pose between the X-ray images and axial preoperative CT images. The registration framework was clinically validated by generating projection images possessing an optimal match with intraoperative X-ray images at the corresponding control point registration. The effectiveness of the registered trajectory was evaluated in terms of displacement and directional errors after reprojecting its position on 2D radiographic planes. The mean Euclidean distances for the Head and Tail end of the reprojected trajectory from the actual trajectory in the AP and lateral planes were shown to be 0.6–0.8 mm and 0.5–1.6 mm, respectively. Similarly, the corresponding mean directional errors were found to be [Formula: see text] and [Formula: see text]. The mean trajectory length difference between the actual and registered trajectory was shown to be 2.67 mm. The approximate time required in the intraoperative environment to axially map the marker position for a single vertebra was found to be 3 min. Utilizing the markerless registration techniques, the designed framework functions like a screw navigation tool, and assures the quality of surgery being performed by limiting the need of postoperative CT. MDPI 2022-07-06 /pmc/articles/PMC9324544/ /pubmed/35877629 http://dx.doi.org/10.3390/jimaging8070185 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Naik, Roshan Ramakrishna Hoblidar, Anitha Bhat, Shyamasunder N. Ampar, Nishanth Kundangar, Raghuraj A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image |
title | A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image |
title_full | A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image |
title_fullStr | A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image |
title_full_unstemmed | A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image |
title_short | A Hybrid 3D-2D Image Registration Framework for Pedicle Screw Trajectory Registration between Intraoperative X-ray Image and Preoperative CT Image |
title_sort | hybrid 3d-2d image registration framework for pedicle screw trajectory registration between intraoperative x-ray image and preoperative ct image |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324544/ https://www.ncbi.nlm.nih.gov/pubmed/35877629 http://dx.doi.org/10.3390/jimaging8070185 |
work_keys_str_mv | AT naikroshanramakrishna ahybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage AT hoblidaranitha ahybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage AT bhatshyamasundern ahybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage AT amparnishanth ahybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage AT kundangarraghuraj ahybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage AT naikroshanramakrishna hybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage AT hoblidaranitha hybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage AT bhatshyamasundern hybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage AT amparnishanth hybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage AT kundangarraghuraj hybrid3d2dimageregistrationframeworkforpediclescrewtrajectoryregistrationbetweenintraoperativexrayimageandpreoperativectimage |