Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators
Lung samplers (periodic sampling) have generally been used to develop CH(4) emission factors in waste incineration facilities. Since this method must be calculated using only the value at a specific point in time, it may not reflect the emission characteristics depending on the circumstances of the...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324669/ https://www.ncbi.nlm.nih.gov/pubmed/35886499 http://dx.doi.org/10.3390/ijerph19148647 |
_version_ | 1784756864870776832 |
---|---|
author | Kang, Seongmin Woo, Jiyun Jeon, Eui-chan |
author_facet | Kang, Seongmin Woo, Jiyun Jeon, Eui-chan |
author_sort | Kang, Seongmin |
collection | PubMed |
description | Lung samplers (periodic sampling) have generally been used to develop CH(4) emission factors in waste incineration facilities. Since this method must be calculated using only the value at a specific point in time, it may not reflect the emission characteristics depending on the circumstances of the facility. In order to supplement this method, a method of continuously collecting samples for a long period of time or continuously measuring may be used. In this study, the CH(4) emission factor development and titration methodology were reviewed using both the existing methods and the newly proposed continuous sampling and continuous measurement methods. As a result of the analysis, the average emission factor by periodic sampling was 0.201 gCH(4)/ton-waste, the average emission factor by continuous capture was 0.199 gCH(4)/ton-waste, and the average emission factor by continuous measurement was 0.176 gCH(4)/ton-waste. There was a difference of 0.025 gCH(4)/ton-waste in the emission factor values by periodic sampling and continuous measurement, and the emission factor values for periodic sampling and continuous sampling were similar. There was no statistically significant difference, confirming that all three methods could be used. However, the existing method, periodic sampling, cannot reflect the characteristics of the night, and, in the case of continuous measurement, expensive equipment and maintenance are difficult. Therefore, it is judged that the method using continuous sampling is a good method that can combine the two advantages. |
format | Online Article Text |
id | pubmed-9324669 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93246692022-07-27 Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators Kang, Seongmin Woo, Jiyun Jeon, Eui-chan Int J Environ Res Public Health Article Lung samplers (periodic sampling) have generally been used to develop CH(4) emission factors in waste incineration facilities. Since this method must be calculated using only the value at a specific point in time, it may not reflect the emission characteristics depending on the circumstances of the facility. In order to supplement this method, a method of continuously collecting samples for a long period of time or continuously measuring may be used. In this study, the CH(4) emission factor development and titration methodology were reviewed using both the existing methods and the newly proposed continuous sampling and continuous measurement methods. As a result of the analysis, the average emission factor by periodic sampling was 0.201 gCH(4)/ton-waste, the average emission factor by continuous capture was 0.199 gCH(4)/ton-waste, and the average emission factor by continuous measurement was 0.176 gCH(4)/ton-waste. There was a difference of 0.025 gCH(4)/ton-waste in the emission factor values by periodic sampling and continuous measurement, and the emission factor values for periodic sampling and continuous sampling were similar. There was no statistically significant difference, confirming that all three methods could be used. However, the existing method, periodic sampling, cannot reflect the characteristics of the night, and, in the case of continuous measurement, expensive equipment and maintenance are difficult. Therefore, it is judged that the method using continuous sampling is a good method that can combine the two advantages. MDPI 2022-07-15 /pmc/articles/PMC9324669/ /pubmed/35886499 http://dx.doi.org/10.3390/ijerph19148647 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kang, Seongmin Woo, Jiyun Jeon, Eui-chan Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators |
title | Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators |
title_full | Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators |
title_fullStr | Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators |
title_full_unstemmed | Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators |
title_short | Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators |
title_sort | comparative study of sampling and measurement methods for the development of ch(4) emission factors at msw incinerators |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324669/ https://www.ncbi.nlm.nih.gov/pubmed/35886499 http://dx.doi.org/10.3390/ijerph19148647 |
work_keys_str_mv | AT kangseongmin comparativestudyofsamplingandmeasurementmethodsforthedevelopmentofch4emissionfactorsatmswincinerators AT woojiyun comparativestudyofsamplingandmeasurementmethodsforthedevelopmentofch4emissionfactorsatmswincinerators AT jeoneuichan comparativestudyofsamplingandmeasurementmethodsforthedevelopmentofch4emissionfactorsatmswincinerators |