Cargando…

Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators

Lung samplers (periodic sampling) have generally been used to develop CH(4) emission factors in waste incineration facilities. Since this method must be calculated using only the value at a specific point in time, it may not reflect the emission characteristics depending on the circumstances of the...

Descripción completa

Detalles Bibliográficos
Autores principales: Kang, Seongmin, Woo, Jiyun, Jeon, Eui-chan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324669/
https://www.ncbi.nlm.nih.gov/pubmed/35886499
http://dx.doi.org/10.3390/ijerph19148647
_version_ 1784756864870776832
author Kang, Seongmin
Woo, Jiyun
Jeon, Eui-chan
author_facet Kang, Seongmin
Woo, Jiyun
Jeon, Eui-chan
author_sort Kang, Seongmin
collection PubMed
description Lung samplers (periodic sampling) have generally been used to develop CH(4) emission factors in waste incineration facilities. Since this method must be calculated using only the value at a specific point in time, it may not reflect the emission characteristics depending on the circumstances of the facility. In order to supplement this method, a method of continuously collecting samples for a long period of time or continuously measuring may be used. In this study, the CH(4) emission factor development and titration methodology were reviewed using both the existing methods and the newly proposed continuous sampling and continuous measurement methods. As a result of the analysis, the average emission factor by periodic sampling was 0.201 gCH(4)/ton-waste, the average emission factor by continuous capture was 0.199 gCH(4)/ton-waste, and the average emission factor by continuous measurement was 0.176 gCH(4)/ton-waste. There was a difference of 0.025 gCH(4)/ton-waste in the emission factor values by periodic sampling and continuous measurement, and the emission factor values for periodic sampling and continuous sampling were similar. There was no statistically significant difference, confirming that all three methods could be used. However, the existing method, periodic sampling, cannot reflect the characteristics of the night, and, in the case of continuous measurement, expensive equipment and maintenance are difficult. Therefore, it is judged that the method using continuous sampling is a good method that can combine the two advantages.
format Online
Article
Text
id pubmed-9324669
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93246692022-07-27 Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators Kang, Seongmin Woo, Jiyun Jeon, Eui-chan Int J Environ Res Public Health Article Lung samplers (periodic sampling) have generally been used to develop CH(4) emission factors in waste incineration facilities. Since this method must be calculated using only the value at a specific point in time, it may not reflect the emission characteristics depending on the circumstances of the facility. In order to supplement this method, a method of continuously collecting samples for a long period of time or continuously measuring may be used. In this study, the CH(4) emission factor development and titration methodology were reviewed using both the existing methods and the newly proposed continuous sampling and continuous measurement methods. As a result of the analysis, the average emission factor by periodic sampling was 0.201 gCH(4)/ton-waste, the average emission factor by continuous capture was 0.199 gCH(4)/ton-waste, and the average emission factor by continuous measurement was 0.176 gCH(4)/ton-waste. There was a difference of 0.025 gCH(4)/ton-waste in the emission factor values by periodic sampling and continuous measurement, and the emission factor values for periodic sampling and continuous sampling were similar. There was no statistically significant difference, confirming that all three methods could be used. However, the existing method, periodic sampling, cannot reflect the characteristics of the night, and, in the case of continuous measurement, expensive equipment and maintenance are difficult. Therefore, it is judged that the method using continuous sampling is a good method that can combine the two advantages. MDPI 2022-07-15 /pmc/articles/PMC9324669/ /pubmed/35886499 http://dx.doi.org/10.3390/ijerph19148647 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kang, Seongmin
Woo, Jiyun
Jeon, Eui-chan
Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators
title Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators
title_full Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators
title_fullStr Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators
title_full_unstemmed Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators
title_short Comparative Study of Sampling and Measurement Methods for the Development of CH(4) Emission Factors at MSW Incinerators
title_sort comparative study of sampling and measurement methods for the development of ch(4) emission factors at msw incinerators
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9324669/
https://www.ncbi.nlm.nih.gov/pubmed/35886499
http://dx.doi.org/10.3390/ijerph19148647
work_keys_str_mv AT kangseongmin comparativestudyofsamplingandmeasurementmethodsforthedevelopmentofch4emissionfactorsatmswincinerators
AT woojiyun comparativestudyofsamplingandmeasurementmethodsforthedevelopmentofch4emissionfactorsatmswincinerators
AT jeoneuichan comparativestudyofsamplingandmeasurementmethodsforthedevelopmentofch4emissionfactorsatmswincinerators