Cargando…

A New Technique for Breast Pocket Adjustment: Argon Beam Thermal Capsulorrhaphy

Implant malposition remains one of the main complications of aesthetic breast augmentation and alloplastic breast reconstruction with expanders and implants. Many capsulorrhaphy techniques have been described to adjust the breast pocket and correct the malposition. In this study, we tested the effic...

Descripción completa

Detalles Bibliográficos
Autores principales: Awaida, Cyril J., Paek, Laurence, Danino, Michel Alain
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9325331/
https://www.ncbi.nlm.nih.gov/pubmed/35923993
http://dx.doi.org/10.1097/GOX.0000000000004437
_version_ 1784757025593360384
author Awaida, Cyril J.
Paek, Laurence
Danino, Michel Alain
author_facet Awaida, Cyril J.
Paek, Laurence
Danino, Michel Alain
author_sort Awaida, Cyril J.
collection PubMed
description Implant malposition remains one of the main complications of aesthetic breast augmentation and alloplastic breast reconstruction with expanders and implants. Many capsulorrhaphy techniques have been described to adjust the breast pocket and correct the malposition. In this study, we tested the efficacy of the argon beam coagulator (ABC) for lateral capsulorrhaphy on breast reconstruction patients at the time of expander replacement with a permanent implant. We also experimentally compared the effects of the ABC and the standard electrocautery on fragments of healthy breast capsule. We noted a 69.5% capsule shrinkage with the ABC versus 46.8% with the standard electrocautery. We concluded that breast capsulorrhaphy using the ABC is a safe and efficient technique for the correction of breast implant malposition in both reconstructive and aesthetic breast surgery.
format Online
Article
Text
id pubmed-9325331
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-93253312022-08-02 A New Technique for Breast Pocket Adjustment: Argon Beam Thermal Capsulorrhaphy Awaida, Cyril J. Paek, Laurence Danino, Michel Alain Plast Reconstr Surg Glob Open Breast Implant malposition remains one of the main complications of aesthetic breast augmentation and alloplastic breast reconstruction with expanders and implants. Many capsulorrhaphy techniques have been described to adjust the breast pocket and correct the malposition. In this study, we tested the efficacy of the argon beam coagulator (ABC) for lateral capsulorrhaphy on breast reconstruction patients at the time of expander replacement with a permanent implant. We also experimentally compared the effects of the ABC and the standard electrocautery on fragments of healthy breast capsule. We noted a 69.5% capsule shrinkage with the ABC versus 46.8% with the standard electrocautery. We concluded that breast capsulorrhaphy using the ABC is a safe and efficient technique for the correction of breast implant malposition in both reconstructive and aesthetic breast surgery. Lippincott Williams & Wilkins 2022-07-25 /pmc/articles/PMC9325331/ /pubmed/35923993 http://dx.doi.org/10.1097/GOX.0000000000004437 Text en Copyright © 2022 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of The American Society of Plastic Surgeons. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Breast
Awaida, Cyril J.
Paek, Laurence
Danino, Michel Alain
A New Technique for Breast Pocket Adjustment: Argon Beam Thermal Capsulorrhaphy
title A New Technique for Breast Pocket Adjustment: Argon Beam Thermal Capsulorrhaphy
title_full A New Technique for Breast Pocket Adjustment: Argon Beam Thermal Capsulorrhaphy
title_fullStr A New Technique for Breast Pocket Adjustment: Argon Beam Thermal Capsulorrhaphy
title_full_unstemmed A New Technique for Breast Pocket Adjustment: Argon Beam Thermal Capsulorrhaphy
title_short A New Technique for Breast Pocket Adjustment: Argon Beam Thermal Capsulorrhaphy
title_sort new technique for breast pocket adjustment: argon beam thermal capsulorrhaphy
topic Breast
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9325331/
https://www.ncbi.nlm.nih.gov/pubmed/35923993
http://dx.doi.org/10.1097/GOX.0000000000004437
work_keys_str_mv AT awaidacyrilj anewtechniqueforbreastpocketadjustmentargonbeamthermalcapsulorrhaphy
AT paeklaurence anewtechniqueforbreastpocketadjustmentargonbeamthermalcapsulorrhaphy
AT daninomichelalain anewtechniqueforbreastpocketadjustmentargonbeamthermalcapsulorrhaphy
AT awaidacyrilj newtechniqueforbreastpocketadjustmentargonbeamthermalcapsulorrhaphy
AT paeklaurence newtechniqueforbreastpocketadjustmentargonbeamthermalcapsulorrhaphy
AT daninomichelalain newtechniqueforbreastpocketadjustmentargonbeamthermalcapsulorrhaphy