Cargando…
Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation
BACKGROUND: Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9325381/ https://www.ncbi.nlm.nih.gov/pubmed/35352363 http://dx.doi.org/10.1111/pace.14495 |
_version_ | 1784757037746356224 |
---|---|
author | Bisignani, Antonio Pannone, Luigi Miraglia, Vincenzo Sieira, Juan Iacopino, Saverio Bala, Gezim Ströker, Erwin Overeinder, Ingrid Almorad, Alexandre Gauthey, Anaïs Monaco, Cinzia Paparella, Gaetano Osório, Thiago Guimarães Sorgente, Antonio Jordaens, Luc Brugada, Pedro Chierchia, Gian‐Battista de Asmundis, Carlo |
author_facet | Bisignani, Antonio Pannone, Luigi Miraglia, Vincenzo Sieira, Juan Iacopino, Saverio Bala, Gezim Ströker, Erwin Overeinder, Ingrid Almorad, Alexandre Gauthey, Anaïs Monaco, Cinzia Paparella, Gaetano Osório, Thiago Guimarães Sorgente, Antonio Jordaens, Luc Brugada, Pedro Chierchia, Gian‐Battista de Asmundis, Carlo |
author_sort | Bisignani, Antonio |
collection | PubMed |
description | BACKGROUND: Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving PVI + LAPWI isolation. METHODS: The study was a prospective, non‐randomized, single center study. Forty consecutive patients, undergoing PVI + LAPWI with the novel POLARx™, were compared to 40 consecutive patients who underwent the same procedure with the established Arctic Front Advance PRO™. RESULTS: Acute isolation was achieved in all PVs in both groups and left posterior wall isolation (LAPWI) was achieved in 38 patients (95%) in the POLARx group and in 36 patients (90%) in Arctic Front group. Procedural outcomes were similar between both groups, except for lower temperatures during cryoenergy in the POLARx group, for both pulmonary vein isolation (PVI) and LAPWI. CONCLUSION: LAPWI + PVI with the novel POLARx™ Cryoballoon is feasible and safe; the results are comparable with the Arctic Front Advance PRO™ system. |
format | Online Article Text |
id | pubmed-9325381 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93253812022-07-30 Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation Bisignani, Antonio Pannone, Luigi Miraglia, Vincenzo Sieira, Juan Iacopino, Saverio Bala, Gezim Ströker, Erwin Overeinder, Ingrid Almorad, Alexandre Gauthey, Anaïs Monaco, Cinzia Paparella, Gaetano Osório, Thiago Guimarães Sorgente, Antonio Jordaens, Luc Brugada, Pedro Chierchia, Gian‐Battista de Asmundis, Carlo Pacing Clin Electrophysiol Electrophysiology BACKGROUND: Left atrial posterior wall isolation (LAPWI) is often performed in addition to pulmonary vein isolation (PVI) in the setting of persistent atrial fibrillation (AF) ablation. The aim of this study was to evaluate the feasibility and safety of a new cryoballoon ablation system in achieving PVI + LAPWI isolation. METHODS: The study was a prospective, non‐randomized, single center study. Forty consecutive patients, undergoing PVI + LAPWI with the novel POLARx™, were compared to 40 consecutive patients who underwent the same procedure with the established Arctic Front Advance PRO™. RESULTS: Acute isolation was achieved in all PVs in both groups and left posterior wall isolation (LAPWI) was achieved in 38 patients (95%) in the POLARx group and in 36 patients (90%) in Arctic Front group. Procedural outcomes were similar between both groups, except for lower temperatures during cryoenergy in the POLARx group, for both pulmonary vein isolation (PVI) and LAPWI. CONCLUSION: LAPWI + PVI with the novel POLARx™ Cryoballoon is feasible and safe; the results are comparable with the Arctic Front Advance PRO™ system. John Wiley and Sons Inc. 2022-04-07 2022-05 /pmc/articles/PMC9325381/ /pubmed/35352363 http://dx.doi.org/10.1111/pace.14495 Text en © 2022 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Electrophysiology Bisignani, Antonio Pannone, Luigi Miraglia, Vincenzo Sieira, Juan Iacopino, Saverio Bala, Gezim Ströker, Erwin Overeinder, Ingrid Almorad, Alexandre Gauthey, Anaïs Monaco, Cinzia Paparella, Gaetano Osório, Thiago Guimarães Sorgente, Antonio Jordaens, Luc Brugada, Pedro Chierchia, Gian‐Battista de Asmundis, Carlo Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation |
title | Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation |
title_full | Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation |
title_fullStr | Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation |
title_full_unstemmed | Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation |
title_short | Feasibility and safety of left atrial posterior wall isolation with a new Cryoballoon technology in patients with persistent atrial fibrillation |
title_sort | feasibility and safety of left atrial posterior wall isolation with a new cryoballoon technology in patients with persistent atrial fibrillation |
topic | Electrophysiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9325381/ https://www.ncbi.nlm.nih.gov/pubmed/35352363 http://dx.doi.org/10.1111/pace.14495 |
work_keys_str_mv | AT bisignaniantonio feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT pannoneluigi feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT miragliavincenzo feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT sieirajuan feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT iacopinosaverio feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT balagezim feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT strokererwin feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT overeinderingrid feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT almoradalexandre feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT gautheyanais feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT monacocinzia feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT paparellagaetano feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT osoriothiagoguimaraes feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT sorgenteantonio feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT jordaensluc feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT brugadapedro feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT chierchiagianbattista feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation AT deasmundiscarlo feasibilityandsafetyofleftatrialposteriorwallisolationwithanewcryoballoontechnologyinpatientswithpersistentatrialfibrillation |