Cargando…
Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia
PURPOSE: To investigate the long-term safety and efficacy of monovision surgery using implantable collamer lens V4c (ICL V4c) implantation in myopic patients with early presbyopia. SETTING: Eye and ENT Hospital of Fudan University, Shanghai, China. DESIGN: Prospective case series study. METHODS: Thi...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9325784/ https://www.ncbi.nlm.nih.gov/pubmed/35129628 http://dx.doi.org/10.1007/s00417-021-05545-x |
_version_ | 1784757133522239488 |
---|---|
author | Ye, Yuhao Zhao, Jing Zhang, Zhe Niu, Lingling Shi, Wanru Wang, Xiaoying Zhou, Xingtao |
author_facet | Ye, Yuhao Zhao, Jing Zhang, Zhe Niu, Lingling Shi, Wanru Wang, Xiaoying Zhou, Xingtao |
author_sort | Ye, Yuhao |
collection | PubMed |
description | PURPOSE: To investigate the long-term safety and efficacy of monovision surgery using implantable collamer lens V4c (ICL V4c) implantation in myopic patients with early presbyopia. SETTING: Eye and ENT Hospital of Fudan University, Shanghai, China. DESIGN: Prospective case series study. METHODS: This study included 64 eyes of 32 patients with early presbyopia, who underwent bilateral ICL V4c implantation for myopia correction. Parameters, including mean spherical equivalent (SE), uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure, endothelial cell density, presbyopic add power, visual acuity (logMAR) of dominant eyes (D-eye), nondominant (nD-eye) eyes, and both eyes (Bi) at 0.4 m, 0.8 m, and 5 m were recorded at the last follow-up. RESULTS: All surgeries were uneventful. At the last follow-up, the safety indices were 1.23 ± 0.18 (D-eyes) and 1.21 ± 0.18 (nD-eyes) (p > 0.05); the efficacy indices were 0.95 ± 0.27 (D-eyes) and 0.92 ± 0.28 (nD-eyes) (p < 0.05), the SE was -0.62 ± 0.47 D (D-eyes); and − 1.21 ± 0.78D (nD-eyes) (p < 0.05), presbyopic add power was 1.31 ± 0.58 D. The visual acuity (logMAR) of D-eyes, nD-eyes, and binocular (Bi) at 5.0 m were: 0.06 ± 0.15 (D-eye), 0.21 ± 0.18 (nD-eye), (p < 0.01), and 0.04 ± 0.13 (Bi); 0.8 m: 0.03 ± 0.18 (D-eye), 0.08 ± 0.16 (nD-eye), (p > 0.05), and − 0.02 ± 0.11 (Bi); 0.4 m: 0.08 ± 0.09 (D-eye), − 0.02 ± 0.08 (nD-eye), (p < 0.001), and − 0.03 ± 0.09 (Bi). Subjects were very satisfied or felt excellent with their visual acuity at near (81.25%) and far distances (87.50%), respectively (versus preoperative, p < 0.001). CONCLUSION: Monovision surgery using ICL V4c implantation is safe and practicable for correction of myopes with presbyopia, with long-term efficacy at near and far distances and patient satisfaction. [Image: see text] |
format | Online Article Text |
id | pubmed-9325784 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-93257842022-07-28 Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia Ye, Yuhao Zhao, Jing Zhang, Zhe Niu, Lingling Shi, Wanru Wang, Xiaoying Zhou, Xingtao Graefes Arch Clin Exp Ophthalmol Refractive Surgery PURPOSE: To investigate the long-term safety and efficacy of monovision surgery using implantable collamer lens V4c (ICL V4c) implantation in myopic patients with early presbyopia. SETTING: Eye and ENT Hospital of Fudan University, Shanghai, China. DESIGN: Prospective case series study. METHODS: This study included 64 eyes of 32 patients with early presbyopia, who underwent bilateral ICL V4c implantation for myopia correction. Parameters, including mean spherical equivalent (SE), uncorrected distance visual acuity, corrected distance visual acuity, intraocular pressure, endothelial cell density, presbyopic add power, visual acuity (logMAR) of dominant eyes (D-eye), nondominant (nD-eye) eyes, and both eyes (Bi) at 0.4 m, 0.8 m, and 5 m were recorded at the last follow-up. RESULTS: All surgeries were uneventful. At the last follow-up, the safety indices were 1.23 ± 0.18 (D-eyes) and 1.21 ± 0.18 (nD-eyes) (p > 0.05); the efficacy indices were 0.95 ± 0.27 (D-eyes) and 0.92 ± 0.28 (nD-eyes) (p < 0.05), the SE was -0.62 ± 0.47 D (D-eyes); and − 1.21 ± 0.78D (nD-eyes) (p < 0.05), presbyopic add power was 1.31 ± 0.58 D. The visual acuity (logMAR) of D-eyes, nD-eyes, and binocular (Bi) at 5.0 m were: 0.06 ± 0.15 (D-eye), 0.21 ± 0.18 (nD-eye), (p < 0.01), and 0.04 ± 0.13 (Bi); 0.8 m: 0.03 ± 0.18 (D-eye), 0.08 ± 0.16 (nD-eye), (p > 0.05), and − 0.02 ± 0.11 (Bi); 0.4 m: 0.08 ± 0.09 (D-eye), − 0.02 ± 0.08 (nD-eye), (p < 0.001), and − 0.03 ± 0.09 (Bi). Subjects were very satisfied or felt excellent with their visual acuity at near (81.25%) and far distances (87.50%), respectively (versus preoperative, p < 0.001). CONCLUSION: Monovision surgery using ICL V4c implantation is safe and practicable for correction of myopes with presbyopia, with long-term efficacy at near and far distances and patient satisfaction. [Image: see text] Springer Berlin Heidelberg 2022-02-07 2022 /pmc/articles/PMC9325784/ /pubmed/35129628 http://dx.doi.org/10.1007/s00417-021-05545-x Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Refractive Surgery Ye, Yuhao Zhao, Jing Zhang, Zhe Niu, Lingling Shi, Wanru Wang, Xiaoying Zhou, Xingtao Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia |
title | Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia |
title_full | Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia |
title_fullStr | Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia |
title_full_unstemmed | Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia |
title_short | Long-term follow-up for monovision surgery by Implantable Collamer Lens V4c implantation for myopia correction in early presbyopia |
title_sort | long-term follow-up for monovision surgery by implantable collamer lens v4c implantation for myopia correction in early presbyopia |
topic | Refractive Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9325784/ https://www.ncbi.nlm.nih.gov/pubmed/35129628 http://dx.doi.org/10.1007/s00417-021-05545-x |
work_keys_str_mv | AT yeyuhao longtermfollowupformonovisionsurgerybyimplantablecollamerlensv4cimplantationformyopiacorrectioninearlypresbyopia AT zhaojing longtermfollowupformonovisionsurgerybyimplantablecollamerlensv4cimplantationformyopiacorrectioninearlypresbyopia AT zhangzhe longtermfollowupformonovisionsurgerybyimplantablecollamerlensv4cimplantationformyopiacorrectioninearlypresbyopia AT niulingling longtermfollowupformonovisionsurgerybyimplantablecollamerlensv4cimplantationformyopiacorrectioninearlypresbyopia AT shiwanru longtermfollowupformonovisionsurgerybyimplantablecollamerlensv4cimplantationformyopiacorrectioninearlypresbyopia AT wangxiaoying longtermfollowupformonovisionsurgerybyimplantablecollamerlensv4cimplantationformyopiacorrectioninearlypresbyopia AT zhouxingtao longtermfollowupformonovisionsurgerybyimplantablecollamerlensv4cimplantationformyopiacorrectioninearlypresbyopia |