Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT

Cochlear implants (CIs) are the primary treatment method in patients with profound sensorineural hearing loss. Interpretation of postoperative imaging with conventional energy-integrating detector computed tomography (EID-CT) following CI surgery remains challenging due to metal artifacts. Still, th...

Descripción completa

Detalles Bibliográficos
Autores principales: Waldeck, Stephan, Overhoff, Daniel, Alizadeh, Leona, Becker, Benjamin V., Port, Matthias, Froelich, Matthias F., Brockmann, Marc A., Schumann, Sven, Vogl, Thomas J., Schoenberg, Stefan O., Schmidt, Sandra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9326530/
https://www.ncbi.nlm.nih.gov/pubmed/35894001
http://dx.doi.org/10.3390/tomography8040136
_version_ 1784757307171667968
author Waldeck, Stephan
Overhoff, Daniel
Alizadeh, Leona
Becker, Benjamin V.
Port, Matthias
Froelich, Matthias F.
Brockmann, Marc A.
Schumann, Sven
Vogl, Thomas J.
Schoenberg, Stefan O.
Schmidt, Sandra
author_facet Waldeck, Stephan
Overhoff, Daniel
Alizadeh, Leona
Becker, Benjamin V.
Port, Matthias
Froelich, Matthias F.
Brockmann, Marc A.
Schumann, Sven
Vogl, Thomas J.
Schoenberg, Stefan O.
Schmidt, Sandra
author_sort Waldeck, Stephan
collection PubMed
description Cochlear implants (CIs) are the primary treatment method in patients with profound sensorineural hearing loss. Interpretation of postoperative imaging with conventional energy-integrating detector computed tomography (EID-CT) following CI surgery remains challenging due to metal artifacts. Still, the photon-counting detector (PCD-CT) is a new emerging technology with the potential to eliminate these problems. This study evaluated the performance of virtual monoenergetic (VME) EID-CT images versus PCD-CT in CI imaging. In this cadaveric study, two temporal bone specimens with implanted CIs were scanned with EID-CT and PCD-CT. The images were assessed according to the visibility of interelectrode wire, size of electrode contact, and diameter of halo artifacts. The visibility of interelectrode wire sections was significantly higher when reviewing PCD-CT images. The difference in diameter measurements for electrode contacts between the two CT scanner modalities showed that the PCD-CT technology generally led to significantly larger diameter readings. The larger measurements were closer to the manufacturer’s specifications for the CI electrode. The size of halo artifacts surrounding the electrode contacts did not differ significantly between the two imaging modalities. PCT-CT imaging is a promising technology for CI imaging with improved spatial resolution and better visibility of small structures than conventional EID-CT.
format Online
Article
Text
id pubmed-9326530
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-93265302022-07-28 Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT Waldeck, Stephan Overhoff, Daniel Alizadeh, Leona Becker, Benjamin V. Port, Matthias Froelich, Matthias F. Brockmann, Marc A. Schumann, Sven Vogl, Thomas J. Schoenberg, Stefan O. Schmidt, Sandra Tomography Article Cochlear implants (CIs) are the primary treatment method in patients with profound sensorineural hearing loss. Interpretation of postoperative imaging with conventional energy-integrating detector computed tomography (EID-CT) following CI surgery remains challenging due to metal artifacts. Still, the photon-counting detector (PCD-CT) is a new emerging technology with the potential to eliminate these problems. This study evaluated the performance of virtual monoenergetic (VME) EID-CT images versus PCD-CT in CI imaging. In this cadaveric study, two temporal bone specimens with implanted CIs were scanned with EID-CT and PCD-CT. The images were assessed according to the visibility of interelectrode wire, size of electrode contact, and diameter of halo artifacts. The visibility of interelectrode wire sections was significantly higher when reviewing PCD-CT images. The difference in diameter measurements for electrode contacts between the two CT scanner modalities showed that the PCD-CT technology generally led to significantly larger diameter readings. The larger measurements were closer to the manufacturer’s specifications for the CI electrode. The size of halo artifacts surrounding the electrode contacts did not differ significantly between the two imaging modalities. PCT-CT imaging is a promising technology for CI imaging with improved spatial resolution and better visibility of small structures than conventional EID-CT. MDPI 2022-06-21 /pmc/articles/PMC9326530/ /pubmed/35894001 http://dx.doi.org/10.3390/tomography8040136 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Waldeck, Stephan
Overhoff, Daniel
Alizadeh, Leona
Becker, Benjamin V.
Port, Matthias
Froelich, Matthias F.
Brockmann, Marc A.
Schumann, Sven
Vogl, Thomas J.
Schoenberg, Stefan O.
Schmidt, Sandra
Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT
title Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT
title_full Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT
title_fullStr Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT
title_full_unstemmed Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT
title_short Photon-Counting Detector CT Virtual Monoengergetic Images for Cochlear Implant Visualization—A Head to Head Comparison to Energy-Integrating Detector CT
title_sort photon-counting detector ct virtual monoengergetic images for cochlear implant visualization—a head to head comparison to energy-integrating detector ct
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9326530/
https://www.ncbi.nlm.nih.gov/pubmed/35894001
http://dx.doi.org/10.3390/tomography8040136
work_keys_str_mv AT waldeckstephan photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT overhoffdaniel photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT alizadehleona photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT beckerbenjaminv photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT portmatthias photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT froelichmatthiasf photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT brockmannmarca photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT schumannsven photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT voglthomasj photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT schoenbergstefano photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct
AT schmidtsandra photoncountingdetectorctvirtualmonoengergeticimagesforcochlearimplantvisualizationaheadtoheadcomparisontoenergyintegratingdetectorct