Cargando…

A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study

BACKGROUND: Mechanical preparation and the formation of space for adequate obturation are included in root canal shaping, but the complex root canal anatomy may be affect it. Manufacturers have created different alloys like M-Wire, Blue-Wire, Gold-Wire or R-phase. Objective: This investigation was p...

Descripción completa

Detalles Bibliográficos
Autores principales: Rubio, Jorge, Zarzosa, José-Ignacio, Aranda, Susana, Casino, Alberto, Pallarés, Antonio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9328485/
https://www.ncbi.nlm.nih.gov/pubmed/35912033
http://dx.doi.org/10.4317/jced.59747
_version_ 1784757730361212928
author Rubio, Jorge
Zarzosa, José-Ignacio
Aranda, Susana
Casino, Alberto
Pallarés, Antonio
author_facet Rubio, Jorge
Zarzosa, José-Ignacio
Aranda, Susana
Casino, Alberto
Pallarés, Antonio
author_sort Rubio, Jorge
collection PubMed
description BACKGROUND: Mechanical preparation and the formation of space for adequate obturation are included in root canal shaping, but the complex root canal anatomy may be affect it. Manufacturers have created different alloys like M-Wire, Blue-Wire, Gold-Wire or R-phase. Objective: This investigation was performed to verify the null hypothesis that there were not significant differences between size 25 instruments ESP Files Thermoflex, Protaper Ultimate, Protaper Next, Blueshaper, One Curve and 2Shape about cyclic fatigue and length of broken fragments. MATERIAL AND METHODS: 180 new size 25 files of the systems investigated were selected (n=30). Files were used with Endo Mate DT endo motor with speed and torque recommended by manufacturers, holding the instruments with clamping mechanism, with passive adjustment, glycerine and without pressure in a stainless-steel block. The time was calculated in seconds until fracture. Number of fatigue cycles was determined as (Resistance (s) x Speed)/60. Separated fragment lengths were calculated with digital Vernier caliper. Statistical analysis was carried out with the SPSS 18 programme at a 95% confidence level, using Levene´s Test to compare variances, Welch’s Test to compare means, and Games-Howell´s Test to reveal differences between groups. RESULTS: Levene’s Test determined no equal variances (P<0.05). Welch’s Test and ANOVA (P<0.05) showed significant differences in cyclic fatigue and separated fragment lengths. Games-Howell’s and Bonferroni´s Test established significant differences in multiple comparisons (P<0.05). CONCLUSIONS: ESP Files Thermoflex was superior in cyclic fatigue. About separated fragment lengths, ESP Files Thermoflex, Protaper Ultimate and Blueshaper obtained longer lengths. Key words:Cyclic fatigue, continuous movement, separated fragment lengths, rotary systems.
format Online
Article
Text
id pubmed-9328485
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-93284852022-07-29 A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study Rubio, Jorge Zarzosa, José-Ignacio Aranda, Susana Casino, Alberto Pallarés, Antonio J Clin Exp Dent Research BACKGROUND: Mechanical preparation and the formation of space for adequate obturation are included in root canal shaping, but the complex root canal anatomy may be affect it. Manufacturers have created different alloys like M-Wire, Blue-Wire, Gold-Wire or R-phase. Objective: This investigation was performed to verify the null hypothesis that there were not significant differences between size 25 instruments ESP Files Thermoflex, Protaper Ultimate, Protaper Next, Blueshaper, One Curve and 2Shape about cyclic fatigue and length of broken fragments. MATERIAL AND METHODS: 180 new size 25 files of the systems investigated were selected (n=30). Files were used with Endo Mate DT endo motor with speed and torque recommended by manufacturers, holding the instruments with clamping mechanism, with passive adjustment, glycerine and without pressure in a stainless-steel block. The time was calculated in seconds until fracture. Number of fatigue cycles was determined as (Resistance (s) x Speed)/60. Separated fragment lengths were calculated with digital Vernier caliper. Statistical analysis was carried out with the SPSS 18 programme at a 95% confidence level, using Levene´s Test to compare variances, Welch’s Test to compare means, and Games-Howell´s Test to reveal differences between groups. RESULTS: Levene’s Test determined no equal variances (P<0.05). Welch’s Test and ANOVA (P<0.05) showed significant differences in cyclic fatigue and separated fragment lengths. Games-Howell’s and Bonferroni´s Test established significant differences in multiple comparisons (P<0.05). CONCLUSIONS: ESP Files Thermoflex was superior in cyclic fatigue. About separated fragment lengths, ESP Files Thermoflex, Protaper Ultimate and Blueshaper obtained longer lengths. Key words:Cyclic fatigue, continuous movement, separated fragment lengths, rotary systems. Medicina Oral S.L. 2022-07-01 /pmc/articles/PMC9328485/ /pubmed/35912033 http://dx.doi.org/10.4317/jced.59747 Text en Copyright: © 2022 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Rubio, Jorge
Zarzosa, José-Ignacio
Aranda, Susana
Casino, Alberto
Pallarés, Antonio
A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study
title A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study
title_full A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study
title_fullStr A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study
title_full_unstemmed A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study
title_short A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study
title_sort comparative study of cyclic fatigue of 6 endodontic systems. an in vitro study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9328485/
https://www.ncbi.nlm.nih.gov/pubmed/35912033
http://dx.doi.org/10.4317/jced.59747
work_keys_str_mv AT rubiojorge acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy
AT zarzosajoseignacio acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy
AT arandasusana acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy
AT casinoalberto acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy
AT pallaresantonio acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy
AT rubiojorge comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy
AT zarzosajoseignacio comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy
AT arandasusana comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy
AT casinoalberto comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy
AT pallaresantonio comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy