A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study
BACKGROUND: Mechanical preparation and the formation of space for adequate obturation are included in root canal shaping, but the complex root canal anatomy may be affect it. Manufacturers have created different alloys like M-Wire, Blue-Wire, Gold-Wire or R-phase. Objective: This investigation was p...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9328485/ https://www.ncbi.nlm.nih.gov/pubmed/35912033 http://dx.doi.org/10.4317/jced.59747 |
_version_ | 1784757730361212928 |
---|---|
author | Rubio, Jorge Zarzosa, José-Ignacio Aranda, Susana Casino, Alberto Pallarés, Antonio |
author_facet | Rubio, Jorge Zarzosa, José-Ignacio Aranda, Susana Casino, Alberto Pallarés, Antonio |
author_sort | Rubio, Jorge |
collection | PubMed |
description | BACKGROUND: Mechanical preparation and the formation of space for adequate obturation are included in root canal shaping, but the complex root canal anatomy may be affect it. Manufacturers have created different alloys like M-Wire, Blue-Wire, Gold-Wire or R-phase. Objective: This investigation was performed to verify the null hypothesis that there were not significant differences between size 25 instruments ESP Files Thermoflex, Protaper Ultimate, Protaper Next, Blueshaper, One Curve and 2Shape about cyclic fatigue and length of broken fragments. MATERIAL AND METHODS: 180 new size 25 files of the systems investigated were selected (n=30). Files were used with Endo Mate DT endo motor with speed and torque recommended by manufacturers, holding the instruments with clamping mechanism, with passive adjustment, glycerine and without pressure in a stainless-steel block. The time was calculated in seconds until fracture. Number of fatigue cycles was determined as (Resistance (s) x Speed)/60. Separated fragment lengths were calculated with digital Vernier caliper. Statistical analysis was carried out with the SPSS 18 programme at a 95% confidence level, using Levene´s Test to compare variances, Welch’s Test to compare means, and Games-Howell´s Test to reveal differences between groups. RESULTS: Levene’s Test determined no equal variances (P<0.05). Welch’s Test and ANOVA (P<0.05) showed significant differences in cyclic fatigue and separated fragment lengths. Games-Howell’s and Bonferroni´s Test established significant differences in multiple comparisons (P<0.05). CONCLUSIONS: ESP Files Thermoflex was superior in cyclic fatigue. About separated fragment lengths, ESP Files Thermoflex, Protaper Ultimate and Blueshaper obtained longer lengths. Key words:Cyclic fatigue, continuous movement, separated fragment lengths, rotary systems. |
format | Online Article Text |
id | pubmed-9328485 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93284852022-07-29 A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study Rubio, Jorge Zarzosa, José-Ignacio Aranda, Susana Casino, Alberto Pallarés, Antonio J Clin Exp Dent Research BACKGROUND: Mechanical preparation and the formation of space for adequate obturation are included in root canal shaping, but the complex root canal anatomy may be affect it. Manufacturers have created different alloys like M-Wire, Blue-Wire, Gold-Wire or R-phase. Objective: This investigation was performed to verify the null hypothesis that there were not significant differences between size 25 instruments ESP Files Thermoflex, Protaper Ultimate, Protaper Next, Blueshaper, One Curve and 2Shape about cyclic fatigue and length of broken fragments. MATERIAL AND METHODS: 180 new size 25 files of the systems investigated were selected (n=30). Files were used with Endo Mate DT endo motor with speed and torque recommended by manufacturers, holding the instruments with clamping mechanism, with passive adjustment, glycerine and without pressure in a stainless-steel block. The time was calculated in seconds until fracture. Number of fatigue cycles was determined as (Resistance (s) x Speed)/60. Separated fragment lengths were calculated with digital Vernier caliper. Statistical analysis was carried out with the SPSS 18 programme at a 95% confidence level, using Levene´s Test to compare variances, Welch’s Test to compare means, and Games-Howell´s Test to reveal differences between groups. RESULTS: Levene’s Test determined no equal variances (P<0.05). Welch’s Test and ANOVA (P<0.05) showed significant differences in cyclic fatigue and separated fragment lengths. Games-Howell’s and Bonferroni´s Test established significant differences in multiple comparisons (P<0.05). CONCLUSIONS: ESP Files Thermoflex was superior in cyclic fatigue. About separated fragment lengths, ESP Files Thermoflex, Protaper Ultimate and Blueshaper obtained longer lengths. Key words:Cyclic fatigue, continuous movement, separated fragment lengths, rotary systems. Medicina Oral S.L. 2022-07-01 /pmc/articles/PMC9328485/ /pubmed/35912033 http://dx.doi.org/10.4317/jced.59747 Text en Copyright: © 2022 Medicina Oral S.L. https://creativecommons.org/licenses/by/2.5/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Rubio, Jorge Zarzosa, José-Ignacio Aranda, Susana Casino, Alberto Pallarés, Antonio A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study |
title | A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study |
title_full | A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study |
title_fullStr | A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study |
title_full_unstemmed | A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study |
title_short | A comparative study of cyclic fatigue of 6 endodontic systems. An in vitro study |
title_sort | comparative study of cyclic fatigue of 6 endodontic systems. an in vitro study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9328485/ https://www.ncbi.nlm.nih.gov/pubmed/35912033 http://dx.doi.org/10.4317/jced.59747 |
work_keys_str_mv | AT rubiojorge acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy AT zarzosajoseignacio acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy AT arandasusana acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy AT casinoalberto acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy AT pallaresantonio acomparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy AT rubiojorge comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy AT zarzosajoseignacio comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy AT arandasusana comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy AT casinoalberto comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy AT pallaresantonio comparativestudyofcyclicfatigueof6endodonticsystemsaninvitrostudy |