Cargando…

A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients

To compare the agreement of ocular biometric parameters measured by IOLMaster 500 and IOLMaster 700. This is a prospective study. IOLMaster 500 and IOLMaster 700 were used to measure the axial eye length (AL), corneal flat keratometry (Kf), corneal steep keratometry (Ks), mean keratometry (Km), corn...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Jianhong, Pan, Xiaojing, Zhou, Mingming, Wang, Xiaoyun, Zhu, Hai, Li, Dongfang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9329444/
https://www.ncbi.nlm.nih.gov/pubmed/35896713
http://dx.doi.org/10.1038/s41598-022-16985-8
_version_ 1784757922166734848
author Jiang, Jianhong
Pan, Xiaojing
Zhou, Mingming
Wang, Xiaoyun
Zhu, Hai
Li, Dongfang
author_facet Jiang, Jianhong
Pan, Xiaojing
Zhou, Mingming
Wang, Xiaoyun
Zhu, Hai
Li, Dongfang
author_sort Jiang, Jianhong
collection PubMed
description To compare the agreement of ocular biometric parameters measured by IOLMaster 500 and IOLMaster 700. This is a prospective study. IOLMaster 500 and IOLMaster 700 were used to measure the axial eye length (AL), corneal flat keratometry (Kf), corneal steep keratometry (Ks), mean keratometry (Km), corneal astigmatism(CA), J0, J45, anterior chamber depth (ACD) and corneal horizontal diameter (white-to-white distance, WTW) of 518 eyes (392 patients) with cataracts. Patients were enrolled unilaterally. Subgroup analyses were done according to the AL and Km. The intraclass correlation coefficient (ICC) and Bland–Altman analysis were used to evaluate the agreement. A total of 275 eyes were analyzed. The 95% confidence interval of ICC of the mean AL, Ks, Kf, Km, J0, and ACD values measured by the two instruments are indicative of excellent reliability (P < 0.001). The measurement results of WTW show good reliability (P < 0.001). The ICC of CA is of good reliability in CA < 0.5 D group (P = 0.000) and moderate reliability in the other two groups (P = 0.000). The WTW is the widest range among 95% consistency of the limit range measured by the two instruments. The results of IOLMaster 500 and IOLMaster 700 in measuring AL, keratometry, and ACD in cataract patients are of high agreement.
format Online
Article
Text
id pubmed-9329444
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-93294442022-07-29 A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients Jiang, Jianhong Pan, Xiaojing Zhou, Mingming Wang, Xiaoyun Zhu, Hai Li, Dongfang Sci Rep Article To compare the agreement of ocular biometric parameters measured by IOLMaster 500 and IOLMaster 700. This is a prospective study. IOLMaster 500 and IOLMaster 700 were used to measure the axial eye length (AL), corneal flat keratometry (Kf), corneal steep keratometry (Ks), mean keratometry (Km), corneal astigmatism(CA), J0, J45, anterior chamber depth (ACD) and corneal horizontal diameter (white-to-white distance, WTW) of 518 eyes (392 patients) with cataracts. Patients were enrolled unilaterally. Subgroup analyses were done according to the AL and Km. The intraclass correlation coefficient (ICC) and Bland–Altman analysis were used to evaluate the agreement. A total of 275 eyes were analyzed. The 95% confidence interval of ICC of the mean AL, Ks, Kf, Km, J0, and ACD values measured by the two instruments are indicative of excellent reliability (P < 0.001). The measurement results of WTW show good reliability (P < 0.001). The ICC of CA is of good reliability in CA < 0.5 D group (P = 0.000) and moderate reliability in the other two groups (P = 0.000). The WTW is the widest range among 95% consistency of the limit range measured by the two instruments. The results of IOLMaster 500 and IOLMaster 700 in measuring AL, keratometry, and ACD in cataract patients are of high agreement. Nature Publishing Group UK 2022-07-27 /pmc/articles/PMC9329444/ /pubmed/35896713 http://dx.doi.org/10.1038/s41598-022-16985-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Jiang, Jianhong
Pan, Xiaojing
Zhou, Mingming
Wang, Xiaoyun
Zhu, Hai
Li, Dongfang
A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients
title A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients
title_full A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients
title_fullStr A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients
title_full_unstemmed A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients
title_short A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients
title_sort comparison of iolmaster 500 and iolmaster 700 in the measurement of ocular biometric parameters in cataract patients
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9329444/
https://www.ncbi.nlm.nih.gov/pubmed/35896713
http://dx.doi.org/10.1038/s41598-022-16985-8
work_keys_str_mv AT jiangjianhong acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT panxiaojing acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT zhoumingming acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT wangxiaoyun acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT zhuhai acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT lidongfang acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT jiangjianhong comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT panxiaojing comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT zhoumingming comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT wangxiaoyun comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT zhuhai comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients
AT lidongfang comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients