Cargando…
A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients
To compare the agreement of ocular biometric parameters measured by IOLMaster 500 and IOLMaster 700. This is a prospective study. IOLMaster 500 and IOLMaster 700 were used to measure the axial eye length (AL), corneal flat keratometry (Kf), corneal steep keratometry (Ks), mean keratometry (Km), corn...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9329444/ https://www.ncbi.nlm.nih.gov/pubmed/35896713 http://dx.doi.org/10.1038/s41598-022-16985-8 |
_version_ | 1784757922166734848 |
---|---|
author | Jiang, Jianhong Pan, Xiaojing Zhou, Mingming Wang, Xiaoyun Zhu, Hai Li, Dongfang |
author_facet | Jiang, Jianhong Pan, Xiaojing Zhou, Mingming Wang, Xiaoyun Zhu, Hai Li, Dongfang |
author_sort | Jiang, Jianhong |
collection | PubMed |
description | To compare the agreement of ocular biometric parameters measured by IOLMaster 500 and IOLMaster 700. This is a prospective study. IOLMaster 500 and IOLMaster 700 were used to measure the axial eye length (AL), corneal flat keratometry (Kf), corneal steep keratometry (Ks), mean keratometry (Km), corneal astigmatism(CA), J0, J45, anterior chamber depth (ACD) and corneal horizontal diameter (white-to-white distance, WTW) of 518 eyes (392 patients) with cataracts. Patients were enrolled unilaterally. Subgroup analyses were done according to the AL and Km. The intraclass correlation coefficient (ICC) and Bland–Altman analysis were used to evaluate the agreement. A total of 275 eyes were analyzed. The 95% confidence interval of ICC of the mean AL, Ks, Kf, Km, J0, and ACD values measured by the two instruments are indicative of excellent reliability (P < 0.001). The measurement results of WTW show good reliability (P < 0.001). The ICC of CA is of good reliability in CA < 0.5 D group (P = 0.000) and moderate reliability in the other two groups (P = 0.000). The WTW is the widest range among 95% consistency of the limit range measured by the two instruments. The results of IOLMaster 500 and IOLMaster 700 in measuring AL, keratometry, and ACD in cataract patients are of high agreement. |
format | Online Article Text |
id | pubmed-9329444 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-93294442022-07-29 A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients Jiang, Jianhong Pan, Xiaojing Zhou, Mingming Wang, Xiaoyun Zhu, Hai Li, Dongfang Sci Rep Article To compare the agreement of ocular biometric parameters measured by IOLMaster 500 and IOLMaster 700. This is a prospective study. IOLMaster 500 and IOLMaster 700 were used to measure the axial eye length (AL), corneal flat keratometry (Kf), corneal steep keratometry (Ks), mean keratometry (Km), corneal astigmatism(CA), J0, J45, anterior chamber depth (ACD) and corneal horizontal diameter (white-to-white distance, WTW) of 518 eyes (392 patients) with cataracts. Patients were enrolled unilaterally. Subgroup analyses were done according to the AL and Km. The intraclass correlation coefficient (ICC) and Bland–Altman analysis were used to evaluate the agreement. A total of 275 eyes were analyzed. The 95% confidence interval of ICC of the mean AL, Ks, Kf, Km, J0, and ACD values measured by the two instruments are indicative of excellent reliability (P < 0.001). The measurement results of WTW show good reliability (P < 0.001). The ICC of CA is of good reliability in CA < 0.5 D group (P = 0.000) and moderate reliability in the other two groups (P = 0.000). The WTW is the widest range among 95% consistency of the limit range measured by the two instruments. The results of IOLMaster 500 and IOLMaster 700 in measuring AL, keratometry, and ACD in cataract patients are of high agreement. Nature Publishing Group UK 2022-07-27 /pmc/articles/PMC9329444/ /pubmed/35896713 http://dx.doi.org/10.1038/s41598-022-16985-8 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Jiang, Jianhong Pan, Xiaojing Zhou, Mingming Wang, Xiaoyun Zhu, Hai Li, Dongfang A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients |
title | A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients |
title_full | A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients |
title_fullStr | A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients |
title_full_unstemmed | A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients |
title_short | A comparison of IOLMaster 500 and IOLMaster 700 in the measurement of ocular biometric parameters in cataract patients |
title_sort | comparison of iolmaster 500 and iolmaster 700 in the measurement of ocular biometric parameters in cataract patients |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9329444/ https://www.ncbi.nlm.nih.gov/pubmed/35896713 http://dx.doi.org/10.1038/s41598-022-16985-8 |
work_keys_str_mv | AT jiangjianhong acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT panxiaojing acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT zhoumingming acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT wangxiaoyun acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT zhuhai acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT lidongfang acomparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT jiangjianhong comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT panxiaojing comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT zhoumingming comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT wangxiaoyun comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT zhuhai comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients AT lidongfang comparisonofiolmaster500andiolmaster700inthemeasurementofocularbiometricparametersincataractpatients |