Cargando…

Safety of Dexmedetomidine as an Alternative Pediatric Magnetic Resonance Imaging (MRI) Sedative: A Retrospective Single-Center Study

BACKGROUND: Dexmedetomidine provides anxiolysis, sedation, dose-dependent hypnosis, and mild analgesia with minimal respiratory function effects. The aim of this study was to assess the efficacy and safety of dexmedetomidine for pediatric patients during MRI. MATERIAL/METHODS: We retrospectively ana...

Descripción completa

Detalles Bibliográficos
Autores principales: Liaudanskytė, Kristina, Razlevičė, Ilona, Bukauskas, Tomas, Stremaitytė, Vilija, Lukošienė, Laura, Macas, Andrius
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9331356/
https://www.ncbi.nlm.nih.gov/pubmed/35871270
http://dx.doi.org/10.12659/MSM.936599
_version_ 1784758381903347712
author Liaudanskytė, Kristina
Razlevičė, Ilona
Bukauskas, Tomas
Stremaitytė, Vilija
Lukošienė, Laura
Macas, Andrius
author_facet Liaudanskytė, Kristina
Razlevičė, Ilona
Bukauskas, Tomas
Stremaitytė, Vilija
Lukošienė, Laura
Macas, Andrius
author_sort Liaudanskytė, Kristina
collection PubMed
description BACKGROUND: Dexmedetomidine provides anxiolysis, sedation, dose-dependent hypnosis, and mild analgesia with minimal respiratory function effects. The aim of this study was to assess the efficacy and safety of dexmedetomidine for pediatric patients during MRI. MATERIAL/METHODS: We retrospectively analyzed 87 cases of pediatric sedations for MRI. Dexmedetomidine and a single dose of midazolam were used in all the cases, according to the in-house pediatric sedation protocol for MRI. The patients were divided in to 2 groups: group 1, who reached adequate sedation up to 10 min of induction and group 2, who achieved proper sedation after 10 min. RESULTS: The median age was 3 years (0–17). The median duration of procedure was 75 min (40–150). The induction of standardized sedation was performed without additional sedatives and proper depth of sedation was reached in the majority of cases (94.3%). Five patients (5.7%) received additional sedative after 10 min of induction. The median time of adequate sedation was 8 min (3–13) after induction, and 51% of patients achieved RASS-4 in 8 min. There was no significant difference between groups 1 and 2. Ten patients (11.5%) experienced bradycardia, regardless of the usage of additional drugs, dexmedetomidine boluses, duration of the procedure, or induction time. CONCLUSIONS: High-dose dexmedetomidine with a single dose of midazolam might be an effective combination at the induction stage for pediatric sedation for MRI, with very few adverse events. Over 50% of enrolled patients achieved an adequate level of sedation before 10 min. We conclude that induction of dexmedetomidine infusion can be shortened up to 8 min.
format Online
Article
Text
id pubmed-9331356
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-93313562022-08-09 Safety of Dexmedetomidine as an Alternative Pediatric Magnetic Resonance Imaging (MRI) Sedative: A Retrospective Single-Center Study Liaudanskytė, Kristina Razlevičė, Ilona Bukauskas, Tomas Stremaitytė, Vilija Lukošienė, Laura Macas, Andrius Med Sci Monit Clinical Research BACKGROUND: Dexmedetomidine provides anxiolysis, sedation, dose-dependent hypnosis, and mild analgesia with minimal respiratory function effects. The aim of this study was to assess the efficacy and safety of dexmedetomidine for pediatric patients during MRI. MATERIAL/METHODS: We retrospectively analyzed 87 cases of pediatric sedations for MRI. Dexmedetomidine and a single dose of midazolam were used in all the cases, according to the in-house pediatric sedation protocol for MRI. The patients were divided in to 2 groups: group 1, who reached adequate sedation up to 10 min of induction and group 2, who achieved proper sedation after 10 min. RESULTS: The median age was 3 years (0–17). The median duration of procedure was 75 min (40–150). The induction of standardized sedation was performed without additional sedatives and proper depth of sedation was reached in the majority of cases (94.3%). Five patients (5.7%) received additional sedative after 10 min of induction. The median time of adequate sedation was 8 min (3–13) after induction, and 51% of patients achieved RASS-4 in 8 min. There was no significant difference between groups 1 and 2. Ten patients (11.5%) experienced bradycardia, regardless of the usage of additional drugs, dexmedetomidine boluses, duration of the procedure, or induction time. CONCLUSIONS: High-dose dexmedetomidine with a single dose of midazolam might be an effective combination at the induction stage for pediatric sedation for MRI, with very few adverse events. Over 50% of enrolled patients achieved an adequate level of sedation before 10 min. We conclude that induction of dexmedetomidine infusion can be shortened up to 8 min. International Scientific Literature, Inc. 2022-07-24 /pmc/articles/PMC9331356/ /pubmed/35871270 http://dx.doi.org/10.12659/MSM.936599 Text en © Med Sci Monit, 2022 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Liaudanskytė, Kristina
Razlevičė, Ilona
Bukauskas, Tomas
Stremaitytė, Vilija
Lukošienė, Laura
Macas, Andrius
Safety of Dexmedetomidine as an Alternative Pediatric Magnetic Resonance Imaging (MRI) Sedative: A Retrospective Single-Center Study
title Safety of Dexmedetomidine as an Alternative Pediatric Magnetic Resonance Imaging (MRI) Sedative: A Retrospective Single-Center Study
title_full Safety of Dexmedetomidine as an Alternative Pediatric Magnetic Resonance Imaging (MRI) Sedative: A Retrospective Single-Center Study
title_fullStr Safety of Dexmedetomidine as an Alternative Pediatric Magnetic Resonance Imaging (MRI) Sedative: A Retrospective Single-Center Study
title_full_unstemmed Safety of Dexmedetomidine as an Alternative Pediatric Magnetic Resonance Imaging (MRI) Sedative: A Retrospective Single-Center Study
title_short Safety of Dexmedetomidine as an Alternative Pediatric Magnetic Resonance Imaging (MRI) Sedative: A Retrospective Single-Center Study
title_sort safety of dexmedetomidine as an alternative pediatric magnetic resonance imaging (mri) sedative: a retrospective single-center study
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9331356/
https://www.ncbi.nlm.nih.gov/pubmed/35871270
http://dx.doi.org/10.12659/MSM.936599
work_keys_str_mv AT liaudanskytekristina safetyofdexmedetomidineasanalternativepediatricmagneticresonanceimagingmrisedativearetrospectivesinglecenterstudy
AT razleviceilona safetyofdexmedetomidineasanalternativepediatricmagneticresonanceimagingmrisedativearetrospectivesinglecenterstudy
AT bukauskastomas safetyofdexmedetomidineasanalternativepediatricmagneticresonanceimagingmrisedativearetrospectivesinglecenterstudy
AT stremaitytevilija safetyofdexmedetomidineasanalternativepediatricmagneticresonanceimagingmrisedativearetrospectivesinglecenterstudy
AT lukosienelaura safetyofdexmedetomidineasanalternativepediatricmagneticresonanceimagingmrisedativearetrospectivesinglecenterstudy
AT macasandrius safetyofdexmedetomidineasanalternativepediatricmagneticresonanceimagingmrisedativearetrospectivesinglecenterstudy