New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times
BACKGROUND: Reading capsule endoscopy (CE) is time-consuming. The Express View (EV) (IntroMedic, Seoul, Korea) software was designed to shorten CE video reading. Our primary aim was to evaluate the diagnostic accuracy of EV in detecting significant small-bowel (SB) lesions. We also compared the read...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9332221/ https://www.ncbi.nlm.nih.gov/pubmed/35892494 http://dx.doi.org/10.3390/diagnostics12081783 |
_version_ | 1784758593049853952 |
---|---|
author | Piccirelli, Stefania Mussetto, Alessandro Bellumat, Angelo Cannizzaro, Renato Pennazio, Marco Pezzoli, Alessandro Bizzotto, Alessandra Fusetti, Nadia Valiante, Flavio Hassan, Cesare Pecere, Silvia Koulaouzidis, Anastasios Spada, Cristiano |
author_facet | Piccirelli, Stefania Mussetto, Alessandro Bellumat, Angelo Cannizzaro, Renato Pennazio, Marco Pezzoli, Alessandro Bizzotto, Alessandra Fusetti, Nadia Valiante, Flavio Hassan, Cesare Pecere, Silvia Koulaouzidis, Anastasios Spada, Cristiano |
author_sort | Piccirelli, Stefania |
collection | PubMed |
description | BACKGROUND: Reading capsule endoscopy (CE) is time-consuming. The Express View (EV) (IntroMedic, Seoul, Korea) software was designed to shorten CE video reading. Our primary aim was to evaluate the diagnostic accuracy of EV in detecting significant small-bowel (SB) lesions. We also compared the reading times with EV mode and standard reading (SR). METHODS: 126 patients with suspected SB bleeding and/or suspected neoplasia were prospectively enrolled and underwent SB CE (MiroCam(®)1200, IntroMedic, Seoul, Korea). CE evaluation was performed in standard and EV mode. In case of discrepancies between SR and EV readings, a consensus was reached after reviewing the video segments and the findings were re-classified. RESULTS: The completion rate of SB CE in our cohort was 86.5% and no retention occurred. The per-patient analysis of sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of EV compared to SR were 86%, 86%, 90%, 81%, and 86%, respectively, before consensus. After consensus, they increased to 97%, 100%, 100%, 96%, and 98%, respectively. The median reading time with SR and EV was 71 min (range 26–340) and 13 min (range 3–85), respectively (p < 0.001). CONCLUSIONS: The new-generation EV shows high diagnostic accuracy and significantly reduces CE reading times. |
format | Online Article Text |
id | pubmed-9332221 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-93322212022-07-29 New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times Piccirelli, Stefania Mussetto, Alessandro Bellumat, Angelo Cannizzaro, Renato Pennazio, Marco Pezzoli, Alessandro Bizzotto, Alessandra Fusetti, Nadia Valiante, Flavio Hassan, Cesare Pecere, Silvia Koulaouzidis, Anastasios Spada, Cristiano Diagnostics (Basel) Article BACKGROUND: Reading capsule endoscopy (CE) is time-consuming. The Express View (EV) (IntroMedic, Seoul, Korea) software was designed to shorten CE video reading. Our primary aim was to evaluate the diagnostic accuracy of EV in detecting significant small-bowel (SB) lesions. We also compared the reading times with EV mode and standard reading (SR). METHODS: 126 patients with suspected SB bleeding and/or suspected neoplasia were prospectively enrolled and underwent SB CE (MiroCam(®)1200, IntroMedic, Seoul, Korea). CE evaluation was performed in standard and EV mode. In case of discrepancies between SR and EV readings, a consensus was reached after reviewing the video segments and the findings were re-classified. RESULTS: The completion rate of SB CE in our cohort was 86.5% and no retention occurred. The per-patient analysis of sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of EV compared to SR were 86%, 86%, 90%, 81%, and 86%, respectively, before consensus. After consensus, they increased to 97%, 100%, 100%, 96%, and 98%, respectively. The median reading time with SR and EV was 71 min (range 26–340) and 13 min (range 3–85), respectively (p < 0.001). CONCLUSIONS: The new-generation EV shows high diagnostic accuracy and significantly reduces CE reading times. MDPI 2022-07-22 /pmc/articles/PMC9332221/ /pubmed/35892494 http://dx.doi.org/10.3390/diagnostics12081783 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Piccirelli, Stefania Mussetto, Alessandro Bellumat, Angelo Cannizzaro, Renato Pennazio, Marco Pezzoli, Alessandro Bizzotto, Alessandra Fusetti, Nadia Valiante, Flavio Hassan, Cesare Pecere, Silvia Koulaouzidis, Anastasios Spada, Cristiano New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times |
title | New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times |
title_full | New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times |
title_fullStr | New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times |
title_full_unstemmed | New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times |
title_short | New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times |
title_sort | new generation express view: an artificial intelligence software effectively reduces capsule endoscopy reading times |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9332221/ https://www.ncbi.nlm.nih.gov/pubmed/35892494 http://dx.doi.org/10.3390/diagnostics12081783 |
work_keys_str_mv | AT piccirellistefania newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT mussettoalessandro newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT bellumatangelo newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT cannizzarorenato newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT pennaziomarco newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT pezzolialessandro newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT bizzottoalessandra newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT fusettinadia newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT valianteflavio newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT hassancesare newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT peceresilvia newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT koulaouzidisanastasios newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes AT spadacristiano newgenerationexpressviewanartificialintelligencesoftwareeffectivelyreducescapsuleendoscopyreadingtimes |