Cargando…

Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients

BACKGROUND: Quantitative pupillometry is part of multimodal neuroprognostication of comatose patients after out-of-hospital cardiac arrest (OHCA). However, the reproducibility, repeatability, and reliability of quantitative pupillometry in this setting have not been investigated. METHODS: In a prosp...

Descripción completa

Detalles Bibliográficos
Autores principales: Nyholm, Benjamin, Obling, Laust, Hassager, Christian, Grand, Johannes, Møller, Jacob, Othman, Marwan, Kondziella, Daniel, Kjaergaard, Jesper
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9333219/
https://www.ncbi.nlm.nih.gov/pubmed/35901103
http://dx.doi.org/10.1371/journal.pone.0272303
_version_ 1784758824010252288
author Nyholm, Benjamin
Obling, Laust
Hassager, Christian
Grand, Johannes
Møller, Jacob
Othman, Marwan
Kondziella, Daniel
Kjaergaard, Jesper
author_facet Nyholm, Benjamin
Obling, Laust
Hassager, Christian
Grand, Johannes
Møller, Jacob
Othman, Marwan
Kondziella, Daniel
Kjaergaard, Jesper
author_sort Nyholm, Benjamin
collection PubMed
description BACKGROUND: Quantitative pupillometry is part of multimodal neuroprognostication of comatose patients after out-of-hospital cardiac arrest (OHCA). However, the reproducibility, repeatability, and reliability of quantitative pupillometry in this setting have not been investigated. METHODS: In a prospective blinded validation study, we compared manual and quantitative measurements of pupil size. Observer and device variability for all available parameters are expressed as mean difference (bias), limits of agreement (LoA), and reliability expressed as intraclass correlation coefficients (ICC) with a 95% confidence interval. RESULTS: Fifty-six unique quadrupled sets of measurement derived from 14 sedated and comatose patients (mean age 70±12 years) were included. For manually measured pupil size, inter-observer bias was -0.14±0.44 mm, LoA of -1.00 to 0.71 mm, and ICC at 0.92 (0.86–0.95). For quantitative pupillometry, we found bias at 0.03±0.17 mm, LoA of -0.31 to 0.36 mm and ICCs at 0.99. Quantitative pupillometry also yielded lower bias and LoA and higher ICC for intra-observer and inter-device measurements. Correlation between manual and automated pupillometry was better in larger pupils, and quantitative pupillometry had less variability and higher ICC, when assessing small pupils. Further, observers failed to detect 26% of the quantitatively estimated abnormal reactivity with manual assessment. We found ICC >0.91 for all quantitative pupillary response parameters (except for latency with ICC 0.81–0.91). CONCLUSION: Automated quantitative pupillometry has excellent reliability and twice the reproducibility and repeatability than manual pupillometry. This study further presents novel estimates of variability for all quantitative pupillary response parameters with excellent reliability.
format Online
Article
Text
id pubmed-9333219
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-93332192022-07-29 Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients Nyholm, Benjamin Obling, Laust Hassager, Christian Grand, Johannes Møller, Jacob Othman, Marwan Kondziella, Daniel Kjaergaard, Jesper PLoS One Research Article BACKGROUND: Quantitative pupillometry is part of multimodal neuroprognostication of comatose patients after out-of-hospital cardiac arrest (OHCA). However, the reproducibility, repeatability, and reliability of quantitative pupillometry in this setting have not been investigated. METHODS: In a prospective blinded validation study, we compared manual and quantitative measurements of pupil size. Observer and device variability for all available parameters are expressed as mean difference (bias), limits of agreement (LoA), and reliability expressed as intraclass correlation coefficients (ICC) with a 95% confidence interval. RESULTS: Fifty-six unique quadrupled sets of measurement derived from 14 sedated and comatose patients (mean age 70±12 years) were included. For manually measured pupil size, inter-observer bias was -0.14±0.44 mm, LoA of -1.00 to 0.71 mm, and ICC at 0.92 (0.86–0.95). For quantitative pupillometry, we found bias at 0.03±0.17 mm, LoA of -0.31 to 0.36 mm and ICCs at 0.99. Quantitative pupillometry also yielded lower bias and LoA and higher ICC for intra-observer and inter-device measurements. Correlation between manual and automated pupillometry was better in larger pupils, and quantitative pupillometry had less variability and higher ICC, when assessing small pupils. Further, observers failed to detect 26% of the quantitatively estimated abnormal reactivity with manual assessment. We found ICC >0.91 for all quantitative pupillary response parameters (except for latency with ICC 0.81–0.91). CONCLUSION: Automated quantitative pupillometry has excellent reliability and twice the reproducibility and repeatability than manual pupillometry. This study further presents novel estimates of variability for all quantitative pupillary response parameters with excellent reliability. Public Library of Science 2022-07-28 /pmc/articles/PMC9333219/ /pubmed/35901103 http://dx.doi.org/10.1371/journal.pone.0272303 Text en © 2022 Nyholm et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Nyholm, Benjamin
Obling, Laust
Hassager, Christian
Grand, Johannes
Møller, Jacob
Othman, Marwan
Kondziella, Daniel
Kjaergaard, Jesper
Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients
title Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients
title_full Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients
title_fullStr Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients
title_full_unstemmed Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients
title_short Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients
title_sort superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9333219/
https://www.ncbi.nlm.nih.gov/pubmed/35901103
http://dx.doi.org/10.1371/journal.pone.0272303
work_keys_str_mv AT nyholmbenjamin superiorreproducibilityandrepeatabilityinautomatedquantitativepupillometrycomparedtostandardmanualassessmentandquantitativepupillaryresponseparameterspresenthighreliabilityincriticallyillcardiacpatients
AT oblinglaust superiorreproducibilityandrepeatabilityinautomatedquantitativepupillometrycomparedtostandardmanualassessmentandquantitativepupillaryresponseparameterspresenthighreliabilityincriticallyillcardiacpatients
AT hassagerchristian superiorreproducibilityandrepeatabilityinautomatedquantitativepupillometrycomparedtostandardmanualassessmentandquantitativepupillaryresponseparameterspresenthighreliabilityincriticallyillcardiacpatients
AT grandjohannes superiorreproducibilityandrepeatabilityinautomatedquantitativepupillometrycomparedtostandardmanualassessmentandquantitativepupillaryresponseparameterspresenthighreliabilityincriticallyillcardiacpatients
AT møllerjacob superiorreproducibilityandrepeatabilityinautomatedquantitativepupillometrycomparedtostandardmanualassessmentandquantitativepupillaryresponseparameterspresenthighreliabilityincriticallyillcardiacpatients
AT othmanmarwan superiorreproducibilityandrepeatabilityinautomatedquantitativepupillometrycomparedtostandardmanualassessmentandquantitativepupillaryresponseparameterspresenthighreliabilityincriticallyillcardiacpatients
AT kondzielladaniel superiorreproducibilityandrepeatabilityinautomatedquantitativepupillometrycomparedtostandardmanualassessmentandquantitativepupillaryresponseparameterspresenthighreliabilityincriticallyillcardiacpatients
AT kjaergaardjesper superiorreproducibilityandrepeatabilityinautomatedquantitativepupillometrycomparedtostandardmanualassessmentandquantitativepupillaryresponseparameterspresenthighreliabilityincriticallyillcardiacpatients