Cargando…
An Assay Combining Droplet Digital PCR With Propidium Monoazide Treatment for the Accurate Detection of Live Cells of Vibrio vulnificus in Plasma Samples
Vibrio vulnificus (V. vulnificus) is one of the most common pathogenic Vibrio species to humans; therefore, the establishment of timely and credible detection methods has become an urgent requirement for V. vulnificus illness surveillance. In this study, an assay combining droplet digital PCR (ddPCR...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9335127/ https://www.ncbi.nlm.nih.gov/pubmed/35910629 http://dx.doi.org/10.3389/fmicb.2022.927285 |
_version_ | 1784759266731622400 |
---|---|
author | Hu, Ling Fu, Yidong Zhang, Shun Pan, Zhilei Xia, Jiang Zhu, Peng Guo, Jing |
author_facet | Hu, Ling Fu, Yidong Zhang, Shun Pan, Zhilei Xia, Jiang Zhu, Peng Guo, Jing |
author_sort | Hu, Ling |
collection | PubMed |
description | Vibrio vulnificus (V. vulnificus) is one of the most common pathogenic Vibrio species to humans; therefore, the establishment of timely and credible detection methods has become an urgent requirement for V. vulnificus illness surveillance. In this study, an assay combining droplet digital PCR (ddPCR) with propidium monoazide (PMA) treatment was developed for detecting V. vulnificus. The primers/probes targeting the V. vulnificus hemolysin A (vvhA) gene, amplification procedures, and PMA processing conditions involved in the assay were optimized. Then, we analyzed the specificity, sensitivity, and ability to detect live cell DNA while testing the performance of PMA-ddPCR in clinical samples. The optimal concentrations of primers and probes were 1.0 and 0.3 μM, respectively. The annealing temperature achieving the highest accuracy in ddPCR assay was 60°C. With an initial V. vulnificus cell concentration of 10(8) CFU/mL (colony-forming units per milliliter), the optimal strategy to distinguish live cells from dead cells was to treat samples with 100 μM PMA for 15 min in the dark and expose them to LED light with an output wavelength of 465 nm for 10 min. The specificity of the PMA-ddPCR assay was tested on 27 strains, including seven V. vulnificus strains and 20 other bacterial strains. Only the seven V. vulnificus strains were observed with positive signals in specificity analysis. Comparative experiments on the detection ability of PMA-ddPCR and PMA-qPCR in pure cultures and plasma samples were performed. The limit of detection (LOD) and the limit of quantitation (LOQ) in pure culture solutions of V. vulnificus were 29.33 and 53.64 CFU/mL in PMA-ddPCR, respectively. For artificially clinical sample tests in PMA-ddPCR, V. vulnificus could be detected at concentrations as low as 65.20 CFU/mL. The sensitivity of the PMA-ddPCR assay was 15- to 40-fold more sensitive than the PMA-qPCR in this study. The PMA-ddPCR assay we developed provides a new insight to accurately detect live cells of V. vulnificus in clinical samples, which is of great significance to enhance public health safety and security capability and improve the emergency response level for V. vulnificus infection. |
format | Online Article Text |
id | pubmed-9335127 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-93351272022-07-30 An Assay Combining Droplet Digital PCR With Propidium Monoazide Treatment for the Accurate Detection of Live Cells of Vibrio vulnificus in Plasma Samples Hu, Ling Fu, Yidong Zhang, Shun Pan, Zhilei Xia, Jiang Zhu, Peng Guo, Jing Front Microbiol Microbiology Vibrio vulnificus (V. vulnificus) is one of the most common pathogenic Vibrio species to humans; therefore, the establishment of timely and credible detection methods has become an urgent requirement for V. vulnificus illness surveillance. In this study, an assay combining droplet digital PCR (ddPCR) with propidium monoazide (PMA) treatment was developed for detecting V. vulnificus. The primers/probes targeting the V. vulnificus hemolysin A (vvhA) gene, amplification procedures, and PMA processing conditions involved in the assay were optimized. Then, we analyzed the specificity, sensitivity, and ability to detect live cell DNA while testing the performance of PMA-ddPCR in clinical samples. The optimal concentrations of primers and probes were 1.0 and 0.3 μM, respectively. The annealing temperature achieving the highest accuracy in ddPCR assay was 60°C. With an initial V. vulnificus cell concentration of 10(8) CFU/mL (colony-forming units per milliliter), the optimal strategy to distinguish live cells from dead cells was to treat samples with 100 μM PMA for 15 min in the dark and expose them to LED light with an output wavelength of 465 nm for 10 min. The specificity of the PMA-ddPCR assay was tested on 27 strains, including seven V. vulnificus strains and 20 other bacterial strains. Only the seven V. vulnificus strains were observed with positive signals in specificity analysis. Comparative experiments on the detection ability of PMA-ddPCR and PMA-qPCR in pure cultures and plasma samples were performed. The limit of detection (LOD) and the limit of quantitation (LOQ) in pure culture solutions of V. vulnificus were 29.33 and 53.64 CFU/mL in PMA-ddPCR, respectively. For artificially clinical sample tests in PMA-ddPCR, V. vulnificus could be detected at concentrations as low as 65.20 CFU/mL. The sensitivity of the PMA-ddPCR assay was 15- to 40-fold more sensitive than the PMA-qPCR in this study. The PMA-ddPCR assay we developed provides a new insight to accurately detect live cells of V. vulnificus in clinical samples, which is of great significance to enhance public health safety and security capability and improve the emergency response level for V. vulnificus infection. Frontiers Media S.A. 2022-07-15 /pmc/articles/PMC9335127/ /pubmed/35910629 http://dx.doi.org/10.3389/fmicb.2022.927285 Text en Copyright © 2022 Hu, Fu, Zhang, Pan, Xia, Zhu and Guo. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Microbiology Hu, Ling Fu, Yidong Zhang, Shun Pan, Zhilei Xia, Jiang Zhu, Peng Guo, Jing An Assay Combining Droplet Digital PCR With Propidium Monoazide Treatment for the Accurate Detection of Live Cells of Vibrio vulnificus in Plasma Samples |
title | An Assay Combining Droplet Digital PCR With Propidium Monoazide Treatment for the Accurate Detection of Live Cells of Vibrio vulnificus in Plasma Samples |
title_full | An Assay Combining Droplet Digital PCR With Propidium Monoazide Treatment for the Accurate Detection of Live Cells of Vibrio vulnificus in Plasma Samples |
title_fullStr | An Assay Combining Droplet Digital PCR With Propidium Monoazide Treatment for the Accurate Detection of Live Cells of Vibrio vulnificus in Plasma Samples |
title_full_unstemmed | An Assay Combining Droplet Digital PCR With Propidium Monoazide Treatment for the Accurate Detection of Live Cells of Vibrio vulnificus in Plasma Samples |
title_short | An Assay Combining Droplet Digital PCR With Propidium Monoazide Treatment for the Accurate Detection of Live Cells of Vibrio vulnificus in Plasma Samples |
title_sort | assay combining droplet digital pcr with propidium monoazide treatment for the accurate detection of live cells of vibrio vulnificus in plasma samples |
topic | Microbiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9335127/ https://www.ncbi.nlm.nih.gov/pubmed/35910629 http://dx.doi.org/10.3389/fmicb.2022.927285 |
work_keys_str_mv | AT huling anassaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT fuyidong anassaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT zhangshun anassaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT panzhilei anassaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT xiajiang anassaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT zhupeng anassaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT guojing anassaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT huling assaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT fuyidong assaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT zhangshun assaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT panzhilei assaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT xiajiang assaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT zhupeng assaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples AT guojing assaycombiningdropletdigitalpcrwithpropidiummonoazidetreatmentfortheaccuratedetectionoflivecellsofvibriovulnificusinplasmasamples |