Cargando…

Real-world use of an etanercept biosimilar including selective versus automatic substitution in inflammatory arthritis patients: a UK-based electronic health records study

OBJECTIVE: Biosimilars are approved as an alternative treatment to their originators. We compared the clinical outcomes of etanercept (ETN) biosimilar compared with ETN originator in real-world practice, from two local health boards in Wales with different policies on switching: automatic vs selecti...

Descripción completa

Detalles Bibliográficos
Autores principales: Cooksey, Roxanne, Brophy, Sinead, Kennedy, Jonathan, Seaborne, Michael, Choy, Ernest
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9336562/
https://www.ncbi.nlm.nih.gov/pubmed/35910710
http://dx.doi.org/10.1093/rap/rkac056
_version_ 1784759565554810880
author Cooksey, Roxanne
Brophy, Sinead
Kennedy, Jonathan
Seaborne, Michael
Choy, Ernest
author_facet Cooksey, Roxanne
Brophy, Sinead
Kennedy, Jonathan
Seaborne, Michael
Choy, Ernest
author_sort Cooksey, Roxanne
collection PubMed
description OBJECTIVE: Biosimilars are approved as an alternative treatment to their originators. We compared the clinical outcomes of etanercept (ETN) biosimilar compared with ETN originator in real-world practice, from two local health boards in Wales with different policies on switching: automatic vs selective. METHODS: Data from the Secure Anonymised Information Linkage (SAIL) databank in Wales were used to create a retrospective cohort study using linked primary and secondary care data. Patients aged ≥18 years with diagnosis codes for RA, PsA or AS were included. Outcomes included treatment failure and DAS-28 score (for RA). The local health board with a policy of automatic switching (i.e. clinician/nurse involvement not mandated) is labelled as automatic switch area, and the other, which required clinician/nurse supervision, as selective switch. RESULTS: Of 8925 individuals with inflammatory arthritis, 13.3% (365) received ETN biosimilar and 31.5% (863) ETN originator. The treatment discontinuation rate was similar for ETN biosimilar and originator by Kaplan–Meier analysis. More biosimilar failure patients were treated in the automatic switch area (15 vs 4.8%). In the automatic switch area, 28.8% (75 of 260) of patients switched automatically from ETN originator to biosimilar compared with 10.5% (11 of 105) in the selective switch area. ETN biosimilar reduced DAS-28 by 1.6 ± 1.8 in the selective switch area vs 0.4 ± 0.6 in the automatic switch area. CONCLUSION: The ETN biosimilar was well tolerated. Fewer people were switched using selective policy, but this was associated with lower failure rates. Automatic switch policy led to more patients being switched and did not lead to significant worsening of disease.
format Online
Article
Text
id pubmed-9336562
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-93365622022-07-29 Real-world use of an etanercept biosimilar including selective versus automatic substitution in inflammatory arthritis patients: a UK-based electronic health records study Cooksey, Roxanne Brophy, Sinead Kennedy, Jonathan Seaborne, Michael Choy, Ernest Rheumatol Adv Pract Original Article OBJECTIVE: Biosimilars are approved as an alternative treatment to their originators. We compared the clinical outcomes of etanercept (ETN) biosimilar compared with ETN originator in real-world practice, from two local health boards in Wales with different policies on switching: automatic vs selective. METHODS: Data from the Secure Anonymised Information Linkage (SAIL) databank in Wales were used to create a retrospective cohort study using linked primary and secondary care data. Patients aged ≥18 years with diagnosis codes for RA, PsA or AS were included. Outcomes included treatment failure and DAS-28 score (for RA). The local health board with a policy of automatic switching (i.e. clinician/nurse involvement not mandated) is labelled as automatic switch area, and the other, which required clinician/nurse supervision, as selective switch. RESULTS: Of 8925 individuals with inflammatory arthritis, 13.3% (365) received ETN biosimilar and 31.5% (863) ETN originator. The treatment discontinuation rate was similar for ETN biosimilar and originator by Kaplan–Meier analysis. More biosimilar failure patients were treated in the automatic switch area (15 vs 4.8%). In the automatic switch area, 28.8% (75 of 260) of patients switched automatically from ETN originator to biosimilar compared with 10.5% (11 of 105) in the selective switch area. ETN biosimilar reduced DAS-28 by 1.6 ± 1.8 in the selective switch area vs 0.4 ± 0.6 in the automatic switch area. CONCLUSION: The ETN biosimilar was well tolerated. Fewer people were switched using selective policy, but this was associated with lower failure rates. Automatic switch policy led to more patients being switched and did not lead to significant worsening of disease. Oxford University Press 2022-07-27 /pmc/articles/PMC9336562/ /pubmed/35910710 http://dx.doi.org/10.1093/rap/rkac056 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of the British Society for Rheumatology. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Cooksey, Roxanne
Brophy, Sinead
Kennedy, Jonathan
Seaborne, Michael
Choy, Ernest
Real-world use of an etanercept biosimilar including selective versus automatic substitution in inflammatory arthritis patients: a UK-based electronic health records study
title Real-world use of an etanercept biosimilar including selective versus automatic substitution in inflammatory arthritis patients: a UK-based electronic health records study
title_full Real-world use of an etanercept biosimilar including selective versus automatic substitution in inflammatory arthritis patients: a UK-based electronic health records study
title_fullStr Real-world use of an etanercept biosimilar including selective versus automatic substitution in inflammatory arthritis patients: a UK-based electronic health records study
title_full_unstemmed Real-world use of an etanercept biosimilar including selective versus automatic substitution in inflammatory arthritis patients: a UK-based electronic health records study
title_short Real-world use of an etanercept biosimilar including selective versus automatic substitution in inflammatory arthritis patients: a UK-based electronic health records study
title_sort real-world use of an etanercept biosimilar including selective versus automatic substitution in inflammatory arthritis patients: a uk-based electronic health records study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9336562/
https://www.ncbi.nlm.nih.gov/pubmed/35910710
http://dx.doi.org/10.1093/rap/rkac056
work_keys_str_mv AT cookseyroxanne realworlduseofanetanerceptbiosimilarincludingselectiveversusautomaticsubstitutionininflammatoryarthritispatientsaukbasedelectronichealthrecordsstudy
AT brophysinead realworlduseofanetanerceptbiosimilarincludingselectiveversusautomaticsubstitutionininflammatoryarthritispatientsaukbasedelectronichealthrecordsstudy
AT kennedyjonathan realworlduseofanetanerceptbiosimilarincludingselectiveversusautomaticsubstitutionininflammatoryarthritispatientsaukbasedelectronichealthrecordsstudy
AT seabornemichael realworlduseofanetanerceptbiosimilarincludingselectiveversusautomaticsubstitutionininflammatoryarthritispatientsaukbasedelectronichealthrecordsstudy
AT choyernest realworlduseofanetanerceptbiosimilarincludingselectiveversusautomaticsubstitutionininflammatoryarthritispatientsaukbasedelectronichealthrecordsstudy