A Case of Device Closure of an Eccentric Atrial Septal Defect Using a Large Device
Device closure of an eccentric atrial septal defect can be challenging and needs technical modifications to avoid unnecessary complications. Here, we present a case of a 45-year-old woman who underwent device closure of an eccentric defect with a large device. The patient developed pericardial effus...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9337235/ https://www.ncbi.nlm.nih.gov/pubmed/35910697 http://dx.doi.org/10.7759/cureus.27447 |
_version_ | 1784759708731572224 |
---|---|
author | Barik, Ramachandra Mahapatra, Rudrapratap |
author_facet | Barik, Ramachandra Mahapatra, Rudrapratap |
author_sort | Barik, Ramachandra |
collection | PubMed |
description | Device closure of an eccentric atrial septal defect can be challenging and needs technical modifications to avoid unnecessary complications. Here, we present a case of a 45-year-old woman who underwent device closure of an eccentric defect with a large device. The patient developed pericardial effusion and left-sided pleural effusion due to injury to the junction of right atrium and superior vena cava because of the malalignment of the delivery sheath and left atrial disc before the device was pulled across the eccentric defect despite releasing the left atrial disc in the left atrium in place of the left pulmonary vein. These two serious complications were managed conservatively with close monitoring of the case during and after the procedure. |
format | Online Article Text |
id | pubmed-9337235 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-93372352022-07-30 A Case of Device Closure of an Eccentric Atrial Septal Defect Using a Large Device Barik, Ramachandra Mahapatra, Rudrapratap Cureus Cardiac/Thoracic/Vascular Surgery Device closure of an eccentric atrial septal defect can be challenging and needs technical modifications to avoid unnecessary complications. Here, we present a case of a 45-year-old woman who underwent device closure of an eccentric defect with a large device. The patient developed pericardial effusion and left-sided pleural effusion due to injury to the junction of right atrium and superior vena cava because of the malalignment of the delivery sheath and left atrial disc before the device was pulled across the eccentric defect despite releasing the left atrial disc in the left atrium in place of the left pulmonary vein. These two serious complications were managed conservatively with close monitoring of the case during and after the procedure. Cureus 2022-07-29 /pmc/articles/PMC9337235/ /pubmed/35910697 http://dx.doi.org/10.7759/cureus.27447 Text en Copyright © 2022, Barik et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Cardiac/Thoracic/Vascular Surgery Barik, Ramachandra Mahapatra, Rudrapratap A Case of Device Closure of an Eccentric Atrial Septal Defect Using a Large Device |
title | A Case of Device Closure of an Eccentric Atrial Septal Defect Using a Large Device |
title_full | A Case of Device Closure of an Eccentric Atrial Septal Defect Using a Large Device |
title_fullStr | A Case of Device Closure of an Eccentric Atrial Septal Defect Using a Large Device |
title_full_unstemmed | A Case of Device Closure of an Eccentric Atrial Septal Defect Using a Large Device |
title_short | A Case of Device Closure of an Eccentric Atrial Septal Defect Using a Large Device |
title_sort | case of device closure of an eccentric atrial septal defect using a large device |
topic | Cardiac/Thoracic/Vascular Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9337235/ https://www.ncbi.nlm.nih.gov/pubmed/35910697 http://dx.doi.org/10.7759/cureus.27447 |
work_keys_str_mv | AT barikramachandra acaseofdeviceclosureofaneccentricatrialseptaldefectusingalargedevice AT mahapatrarudrapratap acaseofdeviceclosureofaneccentricatrialseptaldefectusingalargedevice AT barikramachandra caseofdeviceclosureofaneccentricatrialseptaldefectusingalargedevice AT mahapatrarudrapratap caseofdeviceclosureofaneccentricatrialseptaldefectusingalargedevice |